Showing 1 to 20 of 35 for “"charge detection"”.

  1. Image Charge Detection for Deterministic Ion Implantation

    Image charge detection is presented as a possible candidate to realise deterministic ion implantation. The deterministic placement of single impurities in solid substrates will enable a variety of novel applications, using their quantum mechanical properties for sensors or qubit registers. In this …

    qucosa-diss

  2. Image-Charge Detection – Novel Instrumentation and Applications

    Image-charge detection is an analytical technique in which a highly-charged particle is detected by the magnitude of the image current that it generates in a detecting electrode. This current is represented as a voltage between the charged particle and the sensing electrode. It is a single particle …

    byu Repository record for Image-Charge Detection – Novel Instrumentation and Applications (opens in a new tab) Download PDF for Image-Charge Detection – Novel Instrumentation and Applications (opens in a new tab)

  3. Development and study of charge sensors for fast charge detection in quantum dots

    Charge detection at microsecond time-scales has far reaching consequences in both technology and in our understanding of electron dynamics in nanoscale devices such as quantum dots. Radio-frequency superconducting single electron transistors (RF-SET) and quantum point contacts (QPC) are ultra …

    rice Repository record for Development and study of charge sensors for fast charge detection in quantum dots (opens in a new tab)

  4. Instrumentation and Application of Image-Charge Detection of Electrospray-Charged Microparticles and Microdroplets

    Image-charge detection is emerging as an important tool to analyze heavy and heterogeneous samples because of its unique advantages in measuring highly charged microparticles. Conventional image-charge detection instruments include at least three fundamental components: an ionization source, an …

    byu Repository record for Instrumentation and Application of Image-Charge Detection of Electrospray-Charged Microparticles and Microdroplets (opens in a new tab) Download PDF for Instrumentation and Application of Image-Charge Detection of Electrospray-Charged Microparticles and Microdroplets (opens in a new tab)

  5. Real-Time Virus Analysis Via Image Charge Detection Surface Induced Dissociation Tandem Mass Spectrometry

    … of a novel mass spectrometer combining image charge detection with surface induced dissociation for real-time analysis of intact viruses. Protonated viruses produced using electrospray are accelerated and subsequently impact on a solid surface. Capsid peptides released during the impact are …

    byu Repository record for Real-Time Virus Analysis Via Image Charge Detection Surface Induced Dissociation Tandem Mass Spectrometry (opens in a new tab) Download PDF for Real-Time Virus Analysis Via Image Charge Detection Surface Induced Dissociation Tandem Mass Spectrometry (opens in a new tab)

  6. Advancements in the characterization of intact proteins by ultraviolet photodissociation and charge detection mass spectrometry

    … supercharging conditions. Increasing the protein charge state was found to direct fragmentation towards preferential pathways such as those N-terminal to proline residues or C-terminal to acidic residues (aspartic/glutamic acid), likely due to changes in structure induced by increased coulombic …

    texas Repository record for Advancements in the characterization of intact proteins by ultraviolet photodissociation and charge detection mass spectrometry (opens in a new tab)

  7. Analysis of Mixed Lipid Nanodiscs and Viral Capsids with Native Mass Spectrometry and Charge Detection-Mass Spectrometry

    … extract nanodiscs, we used Orbitrap-based native charge detection mass spectrometry (CD-MS), which simultaneously measures the charge and m/z to get the mass. By using computational deconvolution, we improved the resolution of CD-MS for nanodiscs and AAV capsids. To improve the sensitivity of …

    arizona-thes Repository record for Analysis of Mixed Lipid Nanodiscs and Viral Capsids with Native Mass Spectrometry and Charge Detection-Mass Spectrometry (opens in a new tab)

  8. Charge Detection Mass Spectrometry Using Printed Circuit Board Arrays for the Analysis of Microparticles in the Martian Atmosphere

    Charge detection mass spectrometry (CDMS) is a single particle technique capable of simultaneously measuring charge and mass-to-charge ratios for individual ions or particles. The linear array CDMS design theoretically has no upper mass limit and is therefore a choice method for the analysis of …

    byu Repository record for Charge Detection Mass Spectrometry Using Printed Circuit Board Arrays for the Analysis of Microparticles in the Martian Atmosphere (opens in a new tab) Download PDF for Charge Detection Mass Spectrometry Using Printed Circuit Board Arrays for the Analysis of Microparticles in the Martian Atmosphere (opens in a new tab)

  9. CMOS Charge Amplifier for Scientific Instruments

    Charge detection is essential for a large number of commercial and scientific applications. A charge amplifier is one of the most fundamental building blocks for a detector system. This thesis describes the design, circuit implementation, and post-silicon testing of two different charge amplifier …

    byu Repository record for CMOS Charge Amplifier for Scientific Instruments (opens in a new tab) Download PDF for CMOS Charge Amplifier for Scientific Instruments (opens in a new tab)

  10. Investigating Peptide-Lipid Interactions in Nanodiscs Using Native Mass Spectrometry and Fast Photochemical Oxidation of Peptides

    … in combination with LC-MS-MS and native charge detection-mass spectrometry to study AMP-lipid interactions and surface exposed residues within different lipid bilayer nanodiscs. The findings herein provide complementary information on the potential modes of action and lipid selectivity of …

    arizona-thes Repository record for Investigating Peptide-Lipid Interactions in Nanodiscs Using Native Mass Spectrometry and Fast Photochemical Oxidation of Peptides (opens in a new tab)

  11. Development and Applications of Native Ion Mobility-Mass Spectrometry Methods for Protein Structural and Stability Analysis

    … 3 applies methods including native IM-MS, CIU, charge detection mass spectrometry, mass photometry, and supervised machine learning-based classification to the changes in mAb structure and stability induced by environmental stressors in the context of biotherapeutics. Chapter 4 focuses on the …

    umn Repository record for Development and Applications of Native Ion Mobility-Mass Spectrometry Methods for Protein Structural and Stability Analysis (opens in a new tab)

  12. Substrate engagement mechanism of the bacterial proteasome activator Bpa

    … of an apo undecameric Bpa species via charge detection mass spectrometry (CDMS) and single-particle electron cryomicroscopy (cryo-EM). Characterization of Bpa-substrate interactions is also a major focus of my thesis. Both native (HspR) and non-native (hTRF1) substrate interactions are …

    guelph Repository record for Substrate engagement mechanism of the bacterial proteasome activator Bpa (opens in a new tab)

  13. Dispersive readout of industrially-fabricated silicon quantum dots

    … of qubit readout, which is performed by spin-to-charge conversion in conjunction with a charge sensor. Gate-based dispersive readout is among the most scalable of approaches, for the reason that it does not require doped regions near to the qubit. The technique is performed by connecting an …

    bristol Repository record for Dispersive readout of industrially-fabricated silicon quantum dots (opens in a new tab) Download PDF for Dispersive readout of industrially-fabricated silicon quantum dots (opens in a new tab)

  14. Continuous measurements of small systems: Feedback control, thermodynamics, entanglement

    … quantum dot. A feedback protocol, based on charge detection, transfers electrons against an external voltage bias, without performing any net work. The protocol is studied for both classical and quantum dynamics. We characterize the electronic transport properties, explore …

    lund Repository record for Continuous measurements of small systems: Feedback control, thermodynamics, entanglement (opens in a new tab) Download PDF for Continuous measurements of small systems: Feedback control, thermodynamics, entanglement (opens in a new tab)

  15. Advancing Analytical Sciences Through Innovative Probe Designs

    … sensitivity of native mass spectrometry (MS) and charge-detection mass spectrometry (CD-MS) by surface modifying micropipettes for nanoelectrospray ionization (nESI). Additionally, we conduct a thorough investigation into the mechanisms that underlies the observed improvements. Overall, this …

    arizona-thes Repository record for Advancing Analytical Sciences Through Innovative Probe Designs (opens in a new tab)

  16. Single-electron transistors for detection of charge motion in the solid state

    … single-electron transistor (SET) devices for detection of charge motion in solid-state systems. In particular, novel, nanoscale twin-SET and double-island SET (DISET) detectors are introduced as sensitive charge detectors. Some advantages over conventional SET detectors in terms of noise …

    unsw Repository record for Single-electron transistors for detection of charge motion in the solid state (opens in a new tab)