Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"charge sensitive amplifier"”
-
Synthesis and evaluation of a charge sensitive amplifier for neutron counters
… of the electronic subsystem is a specific preamplifier. The pulse-height distribution curve of the existing preamplifier used in the neutron monitor system at the Centre for Space Research at the North-West University was found to be incorrect, and therefore the pulse-height information cannot …
-
A Low-Noise Lower-Power Charge Sensitive Amplifier for High-Rate Single-Photon Detection
… the design of a 16-channel programmable lownoise charge sensitive amplifier (CSA) for readout of such a detector. The detector uses a photocathode to convert photons into photoelectrons which are subsequently amplified through a microchannel plate (MCP) stack. The resulting charge is then …
-
Trajectory Sensor and Readout Electronics of a Cosmic Dust Telescope
… allow the determination of direction, speed and charge of cosmic dust. The circuit consists of two units, a low noise charge sensitive amplifier optimized for a specified detector capacitance and a multi-channel digital transient recorder. The last converts analog signals on 32 channels and …
-
The Development of a Capacitance-Based Biotelemetry System for Implantable Applications
… biocompatible material. The receiver consists of charge-sensitive amplifier front end using a discriminator to distinguish individual bits. A Field Programmable Gate Array (FPGA) decodes the transmitted data and relays it to a PC- based LabVIEW interface. Test results using a saline-based human …
-
ΥΨΗΛΗΣ ΤΑΧΥΤΗΤΑΣ ΗΛΕΚΤΡΟΝΙΚΑ ΑΝΑΓΝΩΣΗΣ ΑΝΙΧΝΕΥΤΩΝ ΣΕ ΤΕΧΝΟΛΟΓΙΑ VLSI CMOS
… AND GAS CHAMBER DETECTORS THE IONIZATION CHARGE COMES AS A FAST CURRENT PULSE WHOSE AMPLITUDE DROPS BY MORE THAN 90% OF ITS INITIAL VALUE IN LESS THAN 15NS. THE MAJORITY OF THE READOUT CHIPS USE A CHARGE SENSITIVE AMPLIFIER FOLLOWED BY A PULSE SHAPING NETWORK (USUALLY A CR - RC FILTER). …
-
The Boston Extended Amplitude Range (BEAR) IC for energetic particle detection
… (SSD) are used in the direct detection of charged energetic particles and X-rays in different environments ranging from nuclear physics experiments and medical devices on Earth to, satellites in space. Solar energetic particles (SEP) originate at the Sun and are energized and transported by …
-
A High-Resolution Frequency-Division-Multiplexed Single-Photon-Counting CMOS X-Ray Imager
… a phenomenon that minimizes the impact of slow charge trapping in some X-ray sensors to drastically improve energy resolution. However, this stringent area constraint renders conventional per-pixel digitization architectures impractical. The proposed architecture, therefore, uses FDM, which …
-
A single-chip ultra-wideband based wireless sensor network node
… a T-coil load which extends the bandwidth of RF amplifiers, and a novel baseband architecture which relies on parallel analog processing to achieve both low power and fast and accurate signal acquisition and tracking. Other features include a very low power interface to radiation detection …
-
Analysis and design of analog interface circuits for capacitive detector readout systems
… of modern readout systems, the equivalent noise charge equations of the system are derived analytically. The analysis takes into account the stringent requirements of modern readout systems as well as the noise sources associated with deep submicron CMOS technologies. The analysis is based on the …
-
Medipix4, a high granularity four sides buttable pixel readout chip for high resolution spectroscopic X-ray imaging at rates compatible with medical CT scans
… while keeping the spectral fidelity using a charge-sharing correction algorithm. However, its use in medical imaging, synchrotron applications, material analysis, and other applications highlighted some limitations. Indeed, the 3-side buttable architecture in Medipix3RX and other actual X-ray …
-
Design of the Readout chip for CGEM Detector in BESIII Experiment
… used in high energy experiments, like the preamplifier, shaper and discriminator, the ASIC can integrate more digital processing cells, making the ASIC an independent working system. The ASIC will target to meet the requirements of the detector, on aspects like the data rate, charge and time …
-
Design and test of readout electronics for medical and astrophysics applications
… is in the order of 1-3% (r.m.s.), with a 200 fC charge resolution. The thesis author took part in the chip design and fully characterized the device. The same group is currently working on behalf of the MoVeIT collaboration for the development of a new silicon strip detector prototype for …
-
A fully integrated CMOS microelectrode system for electrochemistry
… and a discrete time digital current-to-frequency charge-sensitive amplifier. Working electrodes were designed with a 20 μm side length while the counter and reference electrodes had an 11 μm width. The microelectrodes were designed using the aluminium top metal layer of the CMOS process. The chips …
-
Exploring methods for imaging dynamics in transmission electron microscopy
… that would be difficult to resolve with a charge-coupled device (CCD) camera due to noise, therefore providing an ideal experiment to demonstrate the advantages of the Medipix3 detector and the limits of single-shot imaging. The chapter opens with a presentation of the quality of individual …
-
Luminosity and Time Of Arrival Measurement System With Scalable ADC Backend For Radiation Detectors
… (ADC). The ROIC contains a low noise preamplifier with second stage differential variable gain amplifier, followed by a Constant Fraction Discriminator (CFD). The CFD is used to provide a timing edge, while eliminating the influence of signal intensity on the measured timing (time walk). …
-
Electron Cyclotron Heating and Suprathermal Electron Dynamics in the TCV Tokamak
This thesis is concerned with the physics of suprathermal electrons in thermonuclear, magnetically confined plasmas. Under a variety of conditions, in laboratory as well as space plasmas, the electron velocity distribution function is not in thermodynamic equilibrium owing to internal or external …