Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"closed reduction"”.

  1. Efficacy of closed reduction of nasal fractures- a retrospective analysis with focus on functional and aesthetic outcomes

    … bone fractures. While the nasal anatomy and closed reduction techniques of nasal fractures are well described, there is a paucity of data reporting on the need for revision rhinoplasty. The objective of this study is to analyze the factors affecting the outcome and need for revision …

    zurich

  2. A Computational Biomechanical Model-Based Optimization of Fulcrum Support in Orthosis Enabled Closed Reduction of Developmental Dysplasia of The Hip

    … model provides a variety of scenarios of closed reduction and the location of the OP, which is believed to be a key parameter for a successful reduction in severe cases of DDH. The problem is posed as a maximization of an objective function whose independent parameter is the location of …

    ucf Repository record for A Computational Biomechanical Model-Based Optimization of Fulcrum Support in Orthosis Enabled Closed Reduction of Developmental Dysplasia of The Hip (opens in a new tab)

  3. Biomechanics of Developmental Dysplasia of the Hip - An engineering study of closed reduction utilizing the Pavlik harness for a range of subtle to severe dislocations in infants.

    … is to understand the connection between reductions for subtle and severe dislocations and passive muscle forces and moments generated while the harness is used during treatment. While the understanding of DDH biomechanics will provide a valuable clinically applicable approach to optimize …

    ucf Repository record for Biomechanics of Developmental Dysplasia of the Hip - An engineering study of closed reduction utilizing the Pavlik harness for a range of subtle to severe dislocations in infants. (opens in a new tab)

  4. Adherence to Standard Operating Procedure for patients with Acute Cervical Spine Dislocated Injuries: A case of a teaching central referral hospital in South Africa

    … cervical spine dislocations had on the timing of closed reduction at our hospital. 1.1.2 Patients and methods: The study was a retrospective review of patients who presented to our institution with cervical dislocation injuries and were managed with closed reduction. The patient records of acute …

    cape-town Repository record for Adherence to Standard Operating Procedure for patients with Acute Cervical Spine Dislocated Injuries: A case of a teaching central referral hospital in South Africa (opens in a new tab)

  5. Ketamino panaudojimas sedacijai sukelti, atliekant rinologines operacijas /

    … Most of them are treated by performing a closed reduction. Although general anesthesia is probably the most commonly used anesthesia technique for this surgical intervention, procedural sedation using ketamine remains a truly interesting choice as well. Aim. To compare intravenous sedation …

    vilnius Repository record for Ketamino panaudojimas sedacijai sukelti, atliekant rinologines operacijas / (opens in a new tab)

  6. Clinical outcomes following reduction and pinning of lesser arc injuries without repair of the scapholunate interosseous ligament

    … uncommon. Current recommendations are for open reduction and repair of the interosseous ligaments to prevent the development of scapholunate dissociation and degeneration to a scapholunate advance collapse (SLAC) wrist. This study proposes a less invasive treatment method which includes closed …

    cape-town Repository record for Clinical outcomes following reduction and pinning of lesser arc injuries without repair of the scapholunate interosseous ligament (opens in a new tab)

  7. Simulation-based design of patient-specific femoral locking plate using topology optimization

    … locking plates are orthopedic implants used in closed reduction of the fractured femur. These orthopedic implants designed using conventional methods apply finite element analysis to evaluate their performance. These traditional approaches result in failure of implants and need for revision …

    missouri Repository record for Simulation-based design of patient-specific femoral locking plate using topology optimization (opens in a new tab)

  8. Meta-Analysis of Open vs Closed Surgery of Mandibular Condyle Fractures

    … difference of opinion regarding whether open or closed reduction of condylar fractures produces the best results. It would be beneficial to critically analyze past studies that have directly compared the two methods in an attempt to answer this question. A Medline search for articles using the …

    vcu Repository record for Meta-Analysis of Open vs Closed Surgery of Mandibular Condyle Fractures (opens in a new tab)

  9. Derivation and Internal Validation of a Prediction Model for Hand Fracture Referral Among Pediatric Patients

    … defined as fractures that required surgery, closed reduction or more than four appointments. Multivariable logistic regression with bootstrapping was used to derive and internally validate a model, which was then translated into a risk index. Of 1,173 fractures, 417 (35.6%) met criteria for a …

    calgary Repository record for Derivation and Internal Validation of a Prediction Model for Hand Fracture Referral Among Pediatric Patients (opens in a new tab)

  10. Cambios radiográficos en fracturas de radio distal extraarticulares tratadas con fijación percutanea seis meses después del trauma

    … radius until it heals, however with the use of closed reduction and percutaneous fixation it is not clear whether or not there are radiological changes over time. The anatomical reduction and the persistence of this reduction in the long term determines the likelihood of complications. The aim …

    rosario Repository record for Cambios radiográficos en fracturas de radio distal extraarticulares tratadas con fijación percutanea seis meses después del trauma (opens in a new tab)

  11. Η ΕΝΔΟΠΡΟΘΕΣΗ AML (ANATOMIC MEDULLARY LOCKING) ΣΤΗΝ ΑΝΤΙΜΕΤΩΠΙΣΗ ΤΗΣ ΟΣΤΕΟΑΡΘΡΙΤΙΔΑΣ ΤΟΥ ΙΣΧΙΟΥ

    … WAS ALSO 3 DISLOCATIONS OF THE ARTHROPLASTY. CLOSED REDUCTION UNDER GENERAL ANESTHESIA WAS SUCCESSFULLY PERFORMED. THE FREQUENCY OF THIGH PAIN WAS RELATIVELY SMALL COMPARED WITH ORDER STUDIES. (9% OR 7 PATIENTS). THE PAIN RESPONDED VERY WELL TO MILD ANALGESICS AND NON STEROID ANTI-INFLAMMATORY …

    greece Repository record for Η ΕΝΔΟΠΡΟΘΕΣΗ AML (ANATOMIC MEDULLARY LOCKING) ΣΤΗΝ ΑΝΤΙΜΕΤΩΠΙΣΗ ΤΗΣ ΟΣΤΕΟΑΡΘΡΙΤΙΔΑΣ ΤΟΥ ΙΣΧΙΟΥ (opens in a new tab)

  12. Percutaneous fixation of pelvic ring injuries /

    … amount of exposure is necessary for open reduction internal fixation (ORIF), which carries a high risk of intraoperative and postoperative complications such as deep vein thrombosis, abnormal bone development, nerve and blood artery damage, and significant hemorrhage. Since its inception, …

    vilnius Repository record for Percutaneous fixation of pelvic ring injuries / (opens in a new tab)

  13. Die Geschlossene Reposition Distaler Radiusfrakturen

    Die klassische geschlossene Reposition ist eine sehr effiziente Methode, die anatomische Ergebnisse hinsichtlich vordefinierter Gelenkwinkel liefert. Eine Reposition durch einen alleinigen Aushang reicht nicht aus, um dies zu gewährleisten. Die Repositionsergebnisse sind unabhängig von der …

    fu-berlin Repository record for Die Geschlossene Reposition Distaler Radiusfrakturen (opens in a new tab)

  14. Mechanism of Hip Dysplasia and Identification of the Least Energy Path for its Treatment by using the Principle of Stationary Potential Energy

    … path that the femoral head would follow during reduction. This is achieved by utilizing a validated computational biomechanical model that allows the determination of the potential energy, and then implementing the principle of stationary potential energy. The potential energy stems from strain …

    ucf Repository record for Mechanism of Hip Dysplasia and Identification of the Least Energy Path for its Treatment by using the Principle of Stationary Potential Energy (opens in a new tab)

  15. Fracture of the distal radius - outcome, primary surgery and treatment of malunion

    … or complex DRF were randomized to either closed reduction and external fixation, or open reduction and internal fixation using the TriMed® system. Pronation/supination and grip strength were better in the internal fixation group at one year compared to the external fixation group. There …

    lund Repository record for Fracture of the distal radius - outcome, primary surgery and treatment of malunion (opens in a new tab) Download PDF for Fracture of the distal radius - outcome, primary surgery and treatment of malunion (opens in a new tab)

  16. Retrospective Study of Condyle fracture of the Mandible in children

    Fractures of the facial bones in children are generally associated with mandibular fractures, especially condylar fracture. In this study, 44 pediatric patients were treated at the Ajou University Dental Hospital for the last 10 years under the diagnosis of condylar fractures were analyzed based on …

    ajou Repository record for Retrospective Study of Condyle fracture of the Mandible in children (opens in a new tab) Embargoed until 9999-12-31

  17. Αγγειακή βλάβη στο τραυματικό εξάρθρημα του γόνατος: αναδρομική και νεκροτομική μελέτη

    … fixation and open repair in 1 (2.2%) and closed reduction and casting in 1 (2.2%). All the patients with popliteal artery injuries were treated with femoropopliteal by pass with reverse saphenous vein graft from the contralateral limb. The average Lysholm score was 70.57 and the IKDC …

    greece Repository record for Αγγειακή βλάβη στο τραυματικό εξάρθρημα του γόνατος: αναδρομική και νεκροτομική μελέτη (opens in a new tab)

  18. Treatment of distal radius fractures with volar locking distal radius plates

    … radius fractures was either non-operative, with closed reduction and cast immobilisation, or operative. Operative treatment options are open reduction and internal fixation or closed reduction and fixation with K-wires and/or an external fixator or cast. Until the late 1990s, open reduction and …

    jamescook Download PDF for Treatment of distal radius fractures with volar locking distal radius plates (opens in a new tab)

Page 1 of 2