Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 24 for “"closed tube"”.
-
Forced Resonant Periodic Shock Waves and Mean Pressure Shift in a Closed Tube
… an experiment done in the oscillation of a closed tube near to its fundamental frequency. A tube with a length of ten feet was oscillated via a piston driven by a DC motor. The pressure waveform and mean pressure was recorded at the end of the tube and the mean pressure was measured at the …
-
Improving traceability and detection of food fraud: An exploration of current seafood authentication methods and validation of a novel qPCR and closed-tube barcoding method for commercial species of fish, FASTFISH-ID
… DNA-based authentication method, using qPCR and closed-tube barcoding technology, called FASTFISH-ID, can provide a quick and reliable, first-screening step, in fish authentication.
-
Influence of Processing Techniques on Copper Deep Levels Formation and on Photoconductivity in Silicon Doped Gallium Arsenide
… Three different diffusion techniques, namely, closed tube diffusion, semi-closed tube diffusion, and leaky tube diffusion are used to diffuse copper in GaAs:Si. The diffusion of copper in GaAs is studied for the first time in the present work using the leaky tube diffusion technique, and the …
-
Computer simulation of finite amplitude standing waves in rigid-walled ducts.
… energy losses encountered in a rigid-walled, closed tube of large length-to-diameter ratio was applied to finite-amplitude standing waves by the use of the Fast Fourier Transform. Computer programs were written to determine the amplitudes and phases of the first 255 harmonics. Curves of …
-
A Theoretical Investigation of Finite Amplitude Standing Waves in Rigid Walled Cavities
… energy losses encountered in a rigid walled, closed tube with large length-to-diameter ratio was extended to include sixth order terms. The solution was then investigated to determine the region of validity. Computer programs were written to evaluate and graph the resulting waveforms. …
-
Feedwater Heater Replacement Optimization
The failure of closed, tube and shell type, steam extraction feedwater heaters is a common problem in the utility industry. The effects of these failures are: increased unit down time, reduced unit capability and reduced unit efficiency. The resultant costs can be substantial. The causes of these …
-
Multifunctional wearable fingertip electronics
… outer surfaces of thin, elastomeric sheets in closed-tube geometries, specially formed for mounting on fingertips. Multifunctional systems of this type allow electrotactile stimulation with electrode arrays multiplexed using silicon nanomembrane diodes (Si NM), high-sensitivity strain …
-
Growth, Characterization and Simulation of Tungsten Selenide Thin Films for Photovoltaic Applications
… By means of selenization of tungsten films in a closed tube in a single-zone furnace, highly c-axis orientated P-type WSe2 thin films with a large carrier mobility have been grown. In the second part, multiple sets of simulations of the WSe2 solar cell devices are carried out by using PC1D …
-
Microtubule Sub-Structure and its Role in Protein Binding
… conformations, which diverge greatly from a closed tube conformation. Thus, in this work we explored whether microtubule structure could impact the binding of EB1 to microtubules. Using quantitative fluorescence and electron microcopy experiments, we found that EB1 preferentially binds …
-
ELASTO-PLASTIC ANALYSIS OF PIPES WITH STRAIN HARDENING
… effects of pressure either singly (as in an open tube) or simultaneously with the longitudinal effects (as in a closed tube). The computations proceed with a numerical process utilizing the Newton-Raphson method for the plastic axial stresses and Simpson's rule for the moment and force integrals. …
-
An investigation into the intramedullary pressure rise during femoral nailing: does the level and type of fracture determine peak pressures during the procedure?
… during nailing because there is a long 'closed tube' distal to the fracture. Pressure proximal to the fracture does not reach the same high levels because the intra-medullary content is able to decompress through the fracture as the reamer moves distally. With proximal fractures there is …
-
A Study of Nonlinear Combustion Instability
… against a newly performed simplified acoustic closed tube experiment. This experiment provides the interesting result that in a forced system, as the 2nd harmonic is driven, no energy is transferred back into the 1st mode. The subsequent steepened waveform is a summation of 2nd mode harmonics …
-
Investigation into a magnetic nanoparticle-based molecular diagnostic assay
… this project was to develop a highly sensitive, closed-tube, multiplexed assay for the detection of DNA using surface enhanced Raman scattering (SERS) analysis. This was achieved through the development of a novel molecular diagnostic assay based on nanoparticle assembly combined with a magnetic …
-
Fibronectin and Laminin, extracellular matrix proteins, have an origin in mesoderm tissue and promote anterior neural tube closure in zebrafish
The neural tube, the precursor to the vertebrate central nervous system, forms through the process of neurulation. During neurulation, a flat neural plate folds and the lateral edges bind to form a closed tube. Failure of neurulation results in neural tube defects (NTD). In humans, NTD causes …
-
Assessment of the Contemporary Population Structure and Admixture of Atlantic Swordfish (Xiphias gladius L.) via Mixed Stock Analysis and Bayesian Clustering of Multiple Nuclear SNPS Genotyped through High Resolution Melting
… (HRMA) is shown to be a highly sensitive, rapid, closed-tube genotyping method amenable to high throughput and, though until recently primarily confined to clinical studies, suitable for population studies in non-model species. Ten nuclear markers were genotyped primarily by SA- and UP-HRMA in …
-
Propagation of premixed flames in confined channels
The propagation of premixed flames in confined channels is investigated. In the unconfined case, the structure of the flame and the flame speed for the adiabatic planar flame have been numerically obtained and confirmed with the existing theory. It is seen that in the unconfined case, the flame …
-
Accuracy Improvement for Measurement of Gas Diffusivity through Thin Porous Media
… involving gas transport. The Loschmidt cell, or closed tube method has been extensively used to measuring the binary gas diffusion coefficient of gas pairs. Recent studies have used a modified Loschmidt cell with an additional porous sample to measure the effective diffusion coefficient through …
-
Numerical Methods for Simulating Fluid Motion Driven By Immersed Interface
… and Navier-Stokes fluid through an elastic tube driven by an internal source and sink. </p><p> For the first topic, we developed two second-order accurate method. One is for accurately evaluating boundary integral solutions at a point, and the other is for computing Stokes solution values on …
-
Further characterization and detection of pineapple mealybug wilt associated viruses (PMWAVs)
… highly sensitive detection assay using a single closed tube nested PCR technique has been developed which can be used to detect very low PMWaV-2 titer in diseased plants and insects. The assay is made more flexible by inclusion of a Taqman® probe to make the assay quantitative.
-
Defining a model for anterior neural tube closure in the developing zebrafish embryo
The neural tube is the precursor to the brain and spinal cord and forms through a process called neurulation. Neurulation is a conserved process among vertebrates and begins with a flat epithelium called the neural plate that folds into a closed tube-like structure. When this folding is disrupted, …
Page 1 of 2