Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 65 for “"closed-loop controller"”.

  1. Development of a pneumatic PDMS MEMS actuator using a closed loop controller for endoscopic applications

    … with a PID (Proportional–Integral–Derivative) controller was designed to control the actuator. A feedback control mechanism was designed to eliminate disturbances, and provide a stable position for the actuator. A trial-and-error method, the Matlab® PID Tuner, and Genetic Algorithm were used to …

    ubc Repository record for Development of a pneumatic PDMS MEMS actuator using a closed loop controller for endoscopic applications (opens in a new tab) Download PDF for Development of a pneumatic PDMS MEMS actuator using a closed loop controller for endoscopic applications (opens in a new tab)

  2. Rapid prototyping of a programmable controller for digital microfluidic systems

    … of a DMF device largely depend on improving its controller hardware and fabrication quality. A closed-loop controller uses feedback information to compensate for modeling and run-time uncertainties; thus the controller can improve the accuracy and robustness of droplet operations on a DMF device. …

    ubc Repository record for Rapid prototyping of a programmable controller for digital microfluidic systems (opens in a new tab) Download PDF for Rapid prototyping of a programmable controller for digital microfluidic systems (opens in a new tab)

  3. Precise motion with piezoelectric actuator.

    … and fabricated. In order to design a proper closed-loop controller, the open loop characteristics of the nanopositioner were experimentally investigated.

    ottawa-retro Repository record for Precise motion with piezoelectric actuator. (opens in a new tab)

  4. Sintonia de controladores baseado na incerteza de identificação de sistemas

    … in the covariance matrix. Thus, when designing a controller for an identified model, we can estimate confidence intervals for step and impulse responses, Bode and Nyquist diagrams, through an uncertainty propagation process. Thus, the performance of the closed-loop controller can be seen as a …

    brazil-uerj Repository record for Sintonia de controladores baseado na incerteza de identificação de sistemas (opens in a new tab)

  5. AC power control in the Core Flow Test Loop

    … on a development effort to design an a.c. power controller for the Core Flow Test Loop. The Core Flow Test Loop will be an engineering test facility which will simulate the thermal environment of a gas-cooled fast-breeder reactor. The problems and limitations of using sinusoidal a.c. power to …

    ut-knoxville Repository record for AC power control in the Core Flow Test Loop (opens in a new tab)

  6. Design and control of a lower-limb exoskeleton emulator for accelerated development of gait exoskeletons

    … motors via Bowden-cable transmission. A closed-loop controller utilizing high-frequency real-time measurements provides accurate and responsive torque application to the wearer. A versatile control software model featuring real-time gait event detection has been developed and verified …

    colo-mines Repository record for Design and control of a lower-limb exoskeleton emulator for accelerated development of gait exoskeletons (opens in a new tab)

  7. Development and Integration of Tactile Sensing System

    … with a grasped object. In the last task, a closed loop controller is used to adjust the grip force on the grasped object while the human interacts with it.

    maryland Repository record for Development and Integration of Tactile Sensing System (opens in a new tab)

  8. Optimal Control of a Differential-Drive Mobile Robot

    … based numerical solutions. Lastly, the resulting closed-form expression of control and state profiles are used to design the closed-loop controller utilizing the idea of Differential Flatness.

    buffalo Repository record for Optimal Control of a Differential-Drive Mobile Robot (opens in a new tab)

  9. Hysteresis control of parallel-connected hybrid inverters

    … current-source inverter (CSI). The six-step controller was redesigned to make it independent of the hysteresis controller. The hysteresis controller is fed a reference signal extracted from the total output current. The signal is filtered and modified by the closed-loop system such that the …

    nps Repository record for Hysteresis control of parallel-connected hybrid inverters (opens in a new tab)

  10. Optimal pursuit/evasion spacecraft trajectories in the hill reference frame

    … decreases as propellant is consumed. Optimal closed-loop controllers were also sought, but due to the nature of the minimax problem, creating a traditional closed-loop feedback control is difficult. A closed-loop controller has been developed using a method called kriging. Results for both …

    uiuc Repository record for Optimal pursuit/evasion spacecraft trajectories in the hill reference frame (opens in a new tab)

  11. Reinforcement Learning Applied to Small Agile Fixed-wing Vehicles

    … the work focuses on developing a closed-loop controller<br/>to guide a variable sweep vehicle through a perching manoeuvre.<br/>Variations in training methodology are explored and their effects<br/>on the agent’s performance discussed. In order to extend the work<br/>to more …

    bristol Repository record for Reinforcement Learning Applied to Small Agile Fixed-wing Vehicles (opens in a new tab) Download PDF for Reinforcement Learning Applied to Small Agile Fixed-wing Vehicles (opens in a new tab)

  12. Closed-Loop Thrust and Pressure Profile Throttling of a Nitrous Oxide/Hydroxyl-Terminated Polybutadiene Hybrid Rocket Motor

    … designed, developed, and ground tested a closed-loop throttle controller for a hybrid rocket motor using nitrous oxide and hydroxyl-terminated polybutadiene as propellants. The research simultaneously developed closed-loop throttle algorithms and lab scale motor hardware to evaluate the …

    utahstate Repository record for Closed-Loop Thrust and Pressure Profile Throttling of a Nitrous Oxide/Hydroxyl-Terminated Polybutadiene Hybrid Rocket Motor (opens in a new tab)

  13. REALIZATION OF A DC MICROGRID USING A HAMILTONIAN BASED CONTROLS SOLUTION

    … By using energy storage as actuation within the closed loop controller, the response requirements may be identified while providing a decoupled controller solution. A DC microgrid servicing a fixed RC load through source and bus level storage managed by HSSPFC was realized in hardware. A …

    mtu Repository record for REALIZATION OF A DC MICROGRID USING A HAMILTONIAN BASED CONTROLS SOLUTION (opens in a new tab)

  14. Investigation of Neck Posture and Muscle Activity on Cervical Spine Impact Kinematics Using a Finite Element Human Body Model

    … models have been identified: (1) neck muscle controllers were often tuned to a narrow set of specific load cases, (2) neck models were unable to predict the S-shape (upper cervical spine flexion) magnitude observed in experiments during rear impacts, and (3) defining tissue-level injury …

    waterloo Repository record for Investigation of Neck Posture and Muscle Activity on Cervical Spine Impact Kinematics Using a Finite Element Human Body Model (opens in a new tab)

  15. Integrating Collision Avoidance, Lane Keeping, and Cruise Control With an Optimal Controller and Fuzzy Controller

    … There are three types of collision avoidance controllers, passive, active, and semi-active. This thesis is designed using active collision avoidance controllers. There are two controllers developed for collision avoidance in this paper. They are an optimal controller and a fuzzy controller. …

    vt Repository record for Integrating Collision Avoidance, Lane Keeping, and Cruise Control With an Optimal Controller and Fuzzy Controller (opens in a new tab)

  16. Modeling and control of a Gasoline Direct Injection fuel system

    … developed using MATLAB/Simulink. The pressure controller for the fuel system contains three parts: a bumpless and anti-windup PI (proportional and integral) controller, a feed-forward controller, and a dead-zone compensator. The closed-loop control was simulated and validated in Simulink using …

    msu Repository record for Modeling and control of a Gasoline Direct Injection fuel system (opens in a new tab)

  17. Dynamic Simulation and Neuromuscular Control of Movement: Applications for Predictive Simulations of Balance Recovery

    … was created to combine musculoskeletal modeling, closed-loop forward dynamic simulation, optimization techniques, and neuromuscular control system design. Spinal (stretch-reflex) and supraspinal (operational space task-based) controllers were developed to test simulation-based hypotheses related …

    utk-theses Repository record for Dynamic Simulation and Neuromuscular Control of Movement: Applications for Predictive Simulations of Balance Recovery (opens in a new tab)

  18. A high power interior permanent magnet alternator for automotive applications.

    … measured, forming the basis for the design of a closed-loop controller to regulate the output voltage. The experimental performance and stability of the closed-loop system is examined and evaluated. Further improvements to the output power of the system at low speed using a switched-mode …

    adelaide Repository record for A high power interior permanent magnet alternator for automotive applications. (opens in a new tab)

  19. Closed-Loop Propulsive Control for Very Low Perigee Orbit Energy Management and Stabilization

    … Laboratory. The hybrid motor is paired with a closed-loop controller to provide automatic control. A trajectory simulation was developed to study the performance of multiple closed-loop control options. The results of the trajectory simulation and a best-approach analysis are presented. System …

    utahstate Repository record for Closed-Loop Propulsive Control for Very Low Perigee Orbit Energy Management and Stabilization (opens in a new tab)

Page 1 of 4