Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 34 for “"coaxial probe"”.
-
Measurement of electromagnetic proprties of materials via coaxial probe systems
Thesis (Ph. D.)--Michigan State University. Department of Electrical Engineering, 1993
-
A Novel Genetic Algorithm Based Method for Measuring Complex Permittivity of Dielectric, Lossy and Multilayered Materials with Thin Features Using Open-Ended Coaxial Probe
… permittivity measurements using open-ended coaxial probe (OECP), thin sample measurements present sig- nificant challenges since a large amount of power may go through the sample making the measured complex permittivity values unreliable. We developed a new approach for accurate measurement …
-
Measurement of the Dielectric Properties of Spices and Herbs as a function of Water Activity and Density Packing - By combining coaxial probe and resonant cavity measurements
… dielectric properties had been obtained by a coaxial probe technique, acting in the same frequency range. Water activity and packing density had a big influence upon the dielectric properties, as well as the morphological and physical properties of the spice/herb used.
-
Determining the complex permittivity of materials with the Waveguide-Cutoff method.
… The system is compared to a common Open-Ended Coaxial Probe technique and found to have similar accuracy for determining the dielectric constant over the same frequency band. This system, however, does not suffer from the same restrictions as the coaxial probe and has a much larger bandwidth …
-
Effects of wideband complex electromagnetic properties of soils on geophysical sensor performance, The
… sensor performance. A prototype permittivity probe was used to measure the complex permittivity and conductivity of the soil and calculate the GPR velocity and attenuation of the from the in-situ measurements. The prototype probe was capable of accurately predicting the GPR velocities when …
-
Non-Invasive Milk Quality Monitoring using mm-wave Radar System
… distilled water are measured using an open-ended coaxial probe technique over the frequency range 200 MHz to 20 GHz. The conducted literature survey indicates a decrease in the value of the dielectric constant and an increase of the dielectric loss with an increase in concentration over this …
-
The Finite-Difference Time-Domain Method And Its Application to The Analysis of Microstrip Antennas
… coupled feed, aperture coupled feed, and coaxial probe feed structures. The validity of a coaxial probe feed model is demonstrated by a comparison of simulated and experimental results. For high dielectric constant substrate antennas, the dispersive boundary condition is employed to absorb …
-
On the accuracy of estimating input impedance of probe-fed air-substrate microstrip patch antennas using the theory of characteristic modes
… estimate the input impedance of air-substrate, coaxial probe-fed, microstrip patch antennas with arbitrarily shaped patches. Such an antenna with an L-shaped patch is fabricated and experimentally measured, and a case study performed comparing the accuracy of the two methods. The results of both …
-
Complex electrical properties of shale as a function of frequency and water content
… low frequencies (5 Hz -13 MHz), and open-ended coaxial probe with network analyzer at the high end (20 MHz - 1,3 GHz), The probe technique is simple to use, potentially enabling field measurements of complex permittivity to be taken, although some accuracy is sacrificed. The effects of swelling …
-
Novel designs for broadband and compact dielectric resonator antennas
… mechanisms for the rectangular DRA such as coaxial probe, microstrip slot, and direct microstrip feed are discussed and analyzed using High Frequency Structure Simulator (HFSS). The concept of a small DRA with wideband operation in the 5-6 GHz frequency band is presented. Two new DRA …
-
Analysis of broadband and dual band microstrip patch antennas
… antenna with a circular arc slot and L-shaped probe. The feed for these antennas is a coaxial probe feed. Different parameters such as probe radius, probe location, substrate height, width of the slot and location of the slot are considered in the parametric study. The resonance behavior of a …
-
Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications
… a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the …
-
Estudo de metamaterial têxtil para aplicação em substrato de antenas planares para tecnologia WBAN
… was carried using simulations in HFSS® and the coaxial probe method, to obtain the electrical parameters. The antennas were designed and simulated to operate at 2.45 GHz and 3.5 GHz, with the best results being manufactured and tested in a Vector Network Analyzer (ARV). The results obtained in …
-
Uma nova proposta de antena planar multibanda para comunicações móveis
… microstrip rectangular antennas fed by a coaxial probe. The properties of a linear array of microstrip patch tapered antennas are also investigated. The main parameters of the U slotted tapered microstrip antennas are investigated for different sizes and locations of the slots impressed on …
-
Case studies of microwave applicators for industrial heating processes
… by boundary conditions for multi-layered vi coaxial circular cylindrical structures. Information gained from the normal modes includes suitable geometries of the applicator and possible coupling schemes. Next, optimal dimensions are found for the coupling aperture, which is used for high Q …
-
Multi-Mode Dielectric Resonator Filters
… an 11% size reduction ratio compared with a coaxial air-filled filter with the same unloaded Q-factor (Qu) and about 820 MHz spurious separation from the fundamental frequency 1.95 GHz. Two coupling techniques are applied in the TE11d filter configuration. These are: ceramic puck/probe in …
-
Ceramic waveguide bandpass filters with spurious modes suppression
… than 50% size reduction compared to air-filled coaxial resonator filters with the same unloaded Q-factor. However, the stopband performance of these filters is deteriorated by spurious frequencies of the fundamental mode and higher order modes. The probable solution to reducing the effects of …