Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"cobalt chrome"”.

  1. Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro

    Cobalt Chrome Molybdenum (CoCrMo) remains a popular material choice for femoral condyles in total knee arthroplasty and for acetabular liners in dual mobility total hip designs. CoCrMo has been phased out of conventional THA designs due to its correlation with adverse effects such as ALTR and …

    clemson Repository record for Degradation of Cobalt Chrome Molybdenum Hip And Knee Implants in Vivo and in Vitro (opens in a new tab)

  2. The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems

    … the potential of more flexible and lightweight cobalt chromium molybdenum (CoCrMo) femoral stems that can be manufactured using Selective Laser Melting (SLM). Square pore cellular structures with compressive properties that are similar to human bone have been presented and incorporated into …

    wlv Repository record for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab) Download file for The adoption of laser melting technology for the manufacture of functionally graded cobalt chrome alloy femoral stems (opens in a new tab)

  3. Dermal exposure and surface contamination associated with the use of a cobalt-chrome alloy during additive manufacturing

    … homes, and schools. Metal powders such as cobalt-chrome (CoCr) alloys can be used as feedstock materials for the powder bed fusion (PBF) AM processes. During the activities that form part of the three processing phases of AM (pre-processing, processing, and post-processing), dermal exposure …

    nwu-za Repository record for Dermal exposure and surface contamination associated with the use of a cobalt-chrome alloy during additive manufacturing (opens in a new tab)

  4. Setting Expansion Characteristics of Three Phosphate-Bonded Investment Materials Used with High Fusing High-Noble Alloys, Cobalt-Chrome Alloys and Heat-Pressed Lithium Disilicate Ceramics

    … study were P90 (Powercast 90% Special Liquid for Cobalt-Chrome alloys), P60 (Powercast 60% Special Liquid for High Noble Gold alloys), FF75 (FastFire 15 75% Special Liquid for Cobalt-Chrome alloys), FF50 (FastFire 15 50% Special Liquid for High Noble Gold alloys), and PVS (PressVest Speed 60% …

    tamu Repository record for Setting Expansion Characteristics of Three Phosphate-Bonded Investment Materials Used with High Fusing High-Noble Alloys, Cobalt-Chrome Alloys and Heat-Pressed Lithium Disilicate Ceramics (opens in a new tab)

  5. Spinal Cord Cellular Response To Wear Debris From Metal-on-Metal Total Disc Replacements

    … more accurately determined. Clinically relevant cobalt chrome and stainless steel wear particles were generated using a six-station pin-on-plate wear simulator. Initially in 2D culture C6 glial, PC12 neuronal cells and primary astrocytes with microglia were cultured with increasing concentrations …

    whiterose Download PDF for Spinal Cord Cellular Response To Wear Debris From Metal-on-Metal Total Disc Replacements (opens in a new tab)

  6. Biomechanical Comparison of Titanium and Cobalt Chromium Pedicle Screw Rods in an Unstable Cadaveric Lumbar Spine

    … the most common material for this application. Cobalt-chromium has several advantages over titanium and is generating interest in orthopedic practice. The aim of this study was to compare titanium versus cobalt-chromium rods in posterior fusion, with and without transverse connectors, through in …

    usf Repository record for Biomechanical Comparison of Titanium and Cobalt Chromium Pedicle Screw Rods in an Unstable Cadaveric Lumbar Spine (opens in a new tab)

  7. Hip Replacement Head-Neck Taper Connection Tribocorrosion Reduction by Head Material, Head Size and Taper Geometric Optimization

    … to corrosion of different head sizes (28 vs 36mm cobalt-chrome femoral heads), materials (cobalt-chrome, ceramic and oxidized zirconium) and taper geometry (angle, diameter, length and surface finish). The study of taper geometry followed design of experiments methodology. Twenty-five uniquely …

    toronto-retro Repository record for Hip Replacement Head-Neck Taper Connection Tribocorrosion Reduction by Head Material, Head Size and Taper Geometric Optimization (opens in a new tab)

  8. Monitoring of antimicrobial coatings and biofilm formation on in vitro model of medical implant surfaces

    … and PLGA-Rifampicin-coated stainless steel and cobalt-chrome electrodes were challenged with Staphylococcus aureus and Pseudomonas aeruginosa, with bacterial growth and coating degradation monitored over six months.The results showed that stainless steel and cobalt-chrome electrodes could …

    strathclyde Repository record for Monitoring of antimicrobial coatings and biofilm formation on in vitro model of medical implant surfaces (opens in a new tab)

  9. Analysis of Spinal Rod Deformation After Cutting with a Surgical Rod Cutter

    … two different types of metal rods (Titanium and Cobalt Chrome) resulting in six different experimental groups, were analyzed. Analysis of the deformed rod ends involved assessing the deviating angle of the plasticly deformed region of the rod and the roundness of the deformed cross sections. The …

    ku Repository record for Analysis of Spinal Rod Deformation After Cutting with a Surgical Rod Cutter (opens in a new tab)

  10. Laser surface texturing of biomaterials: from conceptualization to implementation

    … available on laser surface texturing of cobalt chrome alloys, a prevalent implant material, the research presented in this thesis aims to address the suitability of this technology in that context and compare it with the current state-of-the-art in the orthopaedics industry. Furthermore, …

    birmingham Download PDF for Laser surface texturing of biomaterials: from conceptualization to implementation (opens in a new tab)

  11. A Mechanically Alloyed Titanium Aluminide for Use in a Total Artificial Hip

    … sophisticated materials such as titanium and cobalt-chrome alloys which are commonly used today. However, there is still room for improvement in the areas of mechanical properties, fixation and biocompatibility to name a few. This project involves the development of a novel, mechanically …

    marquette Repository record for A Mechanically Alloyed Titanium Aluminide for Use in a Total Artificial Hip (opens in a new tab)

  12. Wear and friction of hylamer and polyethylene against cobalt chromium a pin-on-disc study

    … of one material on a coupon of medical grade cobalt chrome. In this experiment six pins of UHMWPe (ultra high molecular weight polyethylene) and six pins of Hylamer from Du Pont Manufacturing were tested. Four separate runs were made. The tests were performed for ten million cycles, stopping …

    njit Repository record for Wear and friction of hylamer and polyethylene against cobalt chromium a pin-on-disc study (opens in a new tab)

  13. Passividade na interface prótese/pilar intermediário de infraestrutura implantossuportadas confeccionadas pela tecnologia CAD/CAM e método convencional

    … (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was …

    brazil-ufrn Repository record for Passividade na interface prótese/pilar intermediário de infraestrutura implantossuportadas confeccionadas pela tecnologia CAD/CAM e método convencional (opens in a new tab)

  14. Tribological Behavior of Spark Plasma Sintered Tic/graphite/nickel Composites and Cobalt Alloys

    … effects on tribological behavior. Stellite 21, a cobalt‐chrome‐molybdenum alloy, was also produced by SPS. Stellite 21 has low stacking fault energy and a hexagonal phase which forms during sliding that both contribute to low interfacial shear and friction. Samples were investigated by x‐ray …

    unt Repository record for Tribological Behavior of Spark Plasma Sintered Tic/graphite/nickel Composites and Cobalt Alloys (opens in a new tab)

  15. Method to Determine Compressive Bending Performance in Static and Fatigue Loading for Pediatric Non-Fusion Devices

    … analyzed based on the rod material (titanium and cobalt chrome), active length (76-mm and 376-mm), and construct type (F1717 and growing-rod). Results: The force-displacement curves and maximum principle stress for each whole model were evaluated. The longer active lengths required a smaller force …

    umn Repository record for Method to Determine Compressive Bending Performance in Static and Fatigue Loading for Pediatric Non-Fusion Devices (opens in a new tab)

  16. Improved performance of railcar/rail truck interface components

    … protective coatings and steel. Tungsten carbide-cobalt-chrome has a favorable coefficient of 0.3 under standard center bowl/center plate contact conditions.

    tamu Repository record for Improved performance of railcar/rail truck interface components (opens in a new tab)

  17. The development of a posterior dynamic stabilisation implant indicated for thoraco-lumbar disc degeneration

    … alloy Ti6Al4V extra-low interstitial (ELI) and cobalt-chrome-molybdenum (CCM) alloys. The first rapid prototype was manufactured using an additive manufacturing process (3D-printing). The development of the device was performed in three main stages: design, verification and validation. The main …

    nwu-za Repository record for The development of a posterior dynamic stabilisation implant indicated for thoraco-lumbar disc degeneration (opens in a new tab)

  18. Vergleichende Untersuchung verschiedener Metallimplantate auf ihre Osseointegration und Biokompatibilität: eine Studie am Schaf

    … untersucht. Die Materialkonfigurationen waren: Cobalt-Chrom(CC), CC/Titanbeschichtung(CCTC), CC/Zirkonium/Titanbeschichtung (CCZTC), Reintitan (PTST), Stahl, TAN Standard (TANST), TAN new finish (TANNEW). Es wurden 7 Schafe operiert, insgesamt 126 Implantate. Nach 8 Wochen wurden die Proben …

    zurich Repository record for Vergleichende Untersuchung verschiedener Metallimplantate auf ihre Osseointegration und Biokompatibilität: eine Studie am Schaf (opens in a new tab)

  19. SCRATCH DAMAGE EVOLUTION ON METALS IN TOTAL JOINT REPLACEMENTS

    … metallic components on five fabricated F74 cobalt chrome (CoCr) (DJO Austin, TX) wear testing pins; scratch morphology was characterized utilizing a non-contact surface profilometer (WYKO ii NT2000, Veeco Corp., Tucson, AZ). These CoCr pins were exposed to tribologic conditions similar to a …

    clemson Repository record for SCRATCH DAMAGE EVOLUTION ON METALS IN TOTAL JOINT REPLACEMENTS (opens in a new tab)

  20. Characterization of Potential Wear Sources in Knee Arthroplasty Prostheses After In Vivo Function

    … components and tibial baseplates, including cobalt-chrome alloy, titanium alloy, and oxidized zirconium alloy. The purpose of Study 3 is to evaluate the clinical outcomes of 84 patients implanted with primary TKA prostheses of a single design that utilizes a Morse taper feature for attaching …

    clemson Repository record for Characterization of Potential Wear Sources in Knee Arthroplasty Prostheses After In Vivo Function (opens in a new tab)

Page 1 of 2