Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 95 for “"coded aperture"”

  1. Coded aperture imaging

    This thesis studies the coded aperture camera, a device consisting of a conventional camera with a modified aperture mask, that enables the recovery of both depth map and all-in-focus image from a single 2D input image. Key contributions of this work are the modeling of the statistics of natural …

    heriot-watt Repository record for Coded aperture imaging (opens in a new tab)

  2. Coded aperture imaging with a HURA coded aperture and a discrete pixel detector

    … of a hexagonal uniformly redundant array (HURA) coded aperture and a detector consisting of discrete pixels constituted the major research effort associated with this thesis. Such a system offers distinct advantages for the development of advanced gamma ray astronomical telescopes in terms of the …

    soton Repository record for Coded aperture imaging with a HURA coded aperture and a discrete pixel detector (opens in a new tab)

  3. Coded Aperture Phase Contrast Tomosynthesis

    … leading to improved detection of breast lesions. Coded Aperture X-ray Phase Contrast Imaging (CAXPCi) is a technique which enables PC imaging with conventional lab sources, and which could thus be translated into a clinical environment. In this work the feasibility of a combined …

    ucl Repository record for Coded Aperture Phase Contrast Tomosynthesis (opens in a new tab)

  4. Coded Aperture Magnetic Sector Mass Spectrometry

    … usefulness in field applications. </p><p>Spatial aperture coding techniques have been used in optical spectroscopy to achieve large increases in signal intensity without compromising system resolution. In this work similar computational methods are used in the application of these techniques to …

    duke Repository record for Coded Aperture Magnetic Sector Mass Spectrometry (opens in a new tab)

  5. Possibilities and limitations of coded aperture imaging

    We have simulated the performance of various apertures used in Coded Aperture Imaging - optically. Coded pictures of extended and continuous-tone planar objects from the Annulus, Twin Annulus, Fresnel Zone Plate and the Uniformly Redundant Array have been decoded using a noncoherent correlation …

    aston Repository record for Possibilities and limitations of coded aperture imaging (opens in a new tab)

  6. Use of Annular Coded Aperture in Nuclear Imaging

    … affecting the spatial resolution of the system. Coded Aperture imaging is a technique that offers improved detection efficiency. This technique is discussed in this thesis. This technique offers improved photon-collection efficiency over the collimator systems commonly used with high-energy …

    ohiolink Repository record for Use of Annular Coded Aperture in Nuclear Imaging (opens in a new tab)

  7. The optimisation of discrete pixel coded aperture telescopes

    … possible, the fundamental characteristics of coded aperture telescopes based on pixellated detector arrays are investigated in detail. The point source capability of such a telescope is examined first, resulting in a relationship describing the sensitivity dependence on the detector pixel/mask …

    soton Repository record for The optimisation of discrete pixel coded aperture telescopes (opens in a new tab)

  8. Coded-Aperture Compton Camera for Gamma-Ray Imaging

    … security applications implement either a coded aperture or a Compton scattering geometry to image a gamma-ray source. Both of these systems require large, expensive position-sensitive detectors in order to work effectively. By combining characteristics of both of these systems, a new …

    arizona-thes Repository record for Coded-Aperture Compton Camera for Gamma-Ray Imaging (opens in a new tab)

  9. Coded-aperture transaxial tomography using modular gamma cameras.

    … single-crystal scintillation camera and an aperture (collimator) that together only satisfy a small portion of the spatial sampling requirements simultaneously. It would be very desirable to have a stationary data-collection apparatus that allows all spatial sampling in the data set to occur …

    arizona-thes Repository record for Coded-aperture transaxial tomography using modular gamma cameras. (opens in a new tab)

  10. Quantification of Fast-Neutron Sources with Coded Aperture Imaging

    … or within the measurement device. In prior work, coded-aperture fast neutron imaging has been developed to demonstrate the imaging of neutron emitting radiation sources in a qualitative fashion, where the sources may be located meters to tens of meters away. Building upon prior work, this work …

    utk-theses Repository record for Quantification of Fast-Neutron Sources with Coded Aperture Imaging (opens in a new tab)

  11. New generation of coded aperture collimators for imaging ionising radiations

    La visualisation à distance des rayons X et gamma est une mission fondamentale de l'instrumentation nucléaire, avec de nombreuses applications allant de l'espace à la Terre. Dans le domaine de l'astrophysique des hautes énergies, elle permet la détection d'événements cosmologiques transitoires et …

    star-france Repository record for New generation of coded aperture collimators for imaging ionising radiations (opens in a new tab)

  12. A Compact Neutron Scatter Camera Using Optical Coded-Aperture Imaging

    … (meter scale) and not portable. Using optical coded-aperture imaging, fast plastic scintillator, and fast photodetectors that were sensitive to single photons, a portable neutron scatter camera was designed and simulated. The design was optimized, an experimental prototype was constructed, and …

    utk-theses Repository record for A Compact Neutron Scatter Camera Using Optical Coded-Aperture Imaging (opens in a new tab)

  13. The design of a coded aperture mask for Prometheus I

    A coded aperture mask has been designed for Prometheus I, a Rice University gamma-ray telescope sensitive to energies ranging from 0.03 MeV to 6.5 MeV. The mask will allow Prometheus I to record images at those energies. If it is successful, these will be the first astronomical MeV gamma ray images …

    rice Repository record for The design of a coded aperture mask for Prometheus I (opens in a new tab)

  14. Coded Aperture X-ray Tomographic Imaging with Energy Sensitive Detectors

    … the measurement process. The introduction of a coded aperture in a conventional X-ray diffraction system provides 3D localization of the scatterer as well as drastic reductions in the acquisition time due to the ability to perform multiplexed measurements. This theses document contains two …

    duke Repository record for Coded Aperture X-ray Tomographic Imaging with Energy Sensitive Detectors (opens in a new tab)

  15. COORDINATED DESIGN OF RESTORATION ALGORITHM AND CODED APERTURE (RECONSTRUCTION, TOMOGRAPHY).

    Coded-aperture systems are indirect imaging systems that have been used to image x-ray and (gamma)-ray sources. Coded aperture systems are also capable of recording tomographic information and because they involve no detector motion they are natural candidates for use in dynamic studies in nuclear …

    arizona-thes Repository record for COORDINATED DESIGN OF RESTORATION ALGORITHM AND CODED APERTURE (RECONSTRUCTION, TOMOGRAPHY). (opens in a new tab)

  16. Square Coded Aperture: A Large Aperture with Infinite Depth of Field

    We propose a square aperture as a simple and practical alternative to existing coded aperture. A spatial derivative converts sensor measurements taken with a square aperture mask into measurements taken with a pinhole or slit aperture mask. Thus square aperture shares the properties of both large …

    ohiolink Repository record for Square Coded Aperture: A Large Aperture with Infinite Depth of Field (opens in a new tab)

  17. Development of scintillator based coded-aperture neutron imager for nuclear decommissioning

    … study of a novel, scintillator based, coded-aperture approach to neutron detection. Developments presented in this document suggest that coded-aperture approach, previously mainly associated with photon detectors, can be adapted for a small scale neutron detector. This work represents …

    lancaster Repository record for Development of scintillator based coded-aperture neutron imager for nuclear decommissioning (opens in a new tab)

  18. Development and Evaluation of Coded Aperture Reconstruction Methods for Intraoperative Gamma Cameras

    … für die Bilgebung mit einer kodierten Aperture (KA) entwickelt und evaluiert werden. Damit sollen die Vorteile von KA für intraoperative Gamma-Kameras (IGK) nutzbar gemacht werden. Motivation: Brustkrebs bei Frauen hat Lungenkrebs als die am weltweit häufigste diagnostizierte Krebsart …

    karlsruhe-diss Repository record for Development and Evaluation of Coded Aperture Reconstruction Methods for Intraoperative Gamma Cameras (opens in a new tab)

  19. Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction

    … targets by analyzing their shape. Furthermore, a coded aperture used in conjunction with dynamic reconstruction algorithms offers high sensitivity and resolution even while the target is moving towards the detector. This paper describes a lab-based system that simulated a source-target-detector …

    mit Repository record for Long range x-ray imaging utilizing coded aperture techniques and dynamic reconstruction (opens in a new tab)

Page 1 of 5