Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"coded apertures"”.
-
Event Localization In Bulk Scintillator Crystals Using Optical Coded Apertures
… phototransducer. This method uses principles of coded-aperture imaging to localize an event to approximately a 1-cubic-mllimeter voxel in three dimensions inside a large crystal. This work explores all aspects of the concept including current state of the art event localization capabilities, …
-
Coding Strategies for X-ray Tomography
… focuses on the construction and application of coded apertures to compressive X-ray tomography. Coded apertures can be made in a number of ways, each method having an impact on system background and signal contrast. Methods of constructing coded apertures for structuring X-ray illumination and …
-
Συμβολή στην ανάπτυξη φασματοσκοπικού ανιχνευτή γ-ακτινοβολίας με δυνατότητα προσδιορισμού της χωρικής κατανομής των πηγών ραδιενέργειας
… method, applied on two γ-cameras with coded apertures in front of pixelated, CdTe, spectroscopic detectors. Also, the PhD Thesis contributes to the development and the design of the gamma cameras and the selection of the coded aperture technique. These were based on the CdTe pixelated …
-
Coded Aperture Imaging: novel approaches to high-energy high-resolution laboratory imaging
… and utilise the new source potential. Here, coded apertures are used to investigate novel approaches to high-energy high-resolution aperture based imaging. Firstly, coded aperture theory is applied to high-energy x-ray sources such as those generated using laser wakefield techniques. The …
-
Coded-aperture transaxial tomography using modular gamma cameras.
… possibility of using other types of stationary apertures. We demonstrate the capabilities of one such aperture, the pinhole array. The pinhole array is one of many kinds of collimators known as coded apertures. Coded apertures differ from conventional apertures in nuclear medicine in that they …
-
Instrument Design and Study of Operational Characteristics of a Cycloidal Coded Aperture Miniature Mass Spectrometer for Environmental Sensing
… a throughput vs. resolution tradeoff. Spatially coded apertures can break this tradeoff by increasing throughput without sacrificing resolution. Cycloidal sector mass spectrometers are ideal candidates for incorporation of spatially coded apertures when used with array detectors, since they use …
-
Algorithm for Computational Imaging on a Real-Time Hardware
… of projecting the input image onto a series of coded apertures, or spatial intensity masks, that are stored in the ROIC. The real-time, pixel-level projection is achieved by the means of designing a set of coded apertures and programming them in the ROIC as a 2D array of analog biases. The …
-
Charged Particle Optics Simulations and Optimizations for Miniature Mass and Energy Spectrometers
… in question to be determined.In this work, coded apertures are shown to be compatible with sector instruments, though architectural challenges exist. Next, simulation allowed for the discovery of a new class of mass spectrograph which addresses these challenges and is compatible with …
-
Image Quality Modeling and Optimization for Non-Conventional Aperture Imaging Systems
… image quality studies. Examples include sparse apertures, synthetic apertures, coded apertures and phase elements. This work will focus on sparse aperture telescopes and the image quality issues associated with them, however, the methods presented will be applicable to other non-conventional …
-
High-Resolution Gamma-Ray Imaging with Columnar Scintillators and CCD/CMOS Sensors, and FastSPECT III: A Third-Generation Stationary SPECT Imager
… of a gamma-ray microscope using micro-coded apertures, feasibility studies for photon-counting digital mammography and eventually X-ray CT, and FastSPECT III -- a third generation small animal stationary SPECT imager. FastSPECT III system design, fabrication methods, data acquisition …
-
Computational plenoptic image acquisition and display
… factors. In a different application, adaptive coded apertures are introduced to projection displays as next-generation auto-iris systems. Combined with computational processing that exploits limitations of human perception, these systems increase the depth of field and temporal contrast of …
-
Multiple-pinhole transaxial tomography: A model and analysis.
… of Arizona (UA) transaxial systems, consist of coded apertures and modular gamma cameras and acquire data without system motion. They are the only such SPECT systems. This dissertation presents results from studies in which tomography using the UA imagers was simulated and studies in which the …
-
Coded Aperture X-ray Tomographic Imaging with Energy Sensitive Detectors
… the measurement process. The introduction of a coded aperture in a conventional X-ray diffraction system provides 3D localization of the scatterer as well as drastic reductions in the acquisition time due to the ability to perform multiplexed measurements. This theses document contains two …
-
Development of X-ray Fan Beam Coded Aperture Diffraction Imaging for Improving Breast Cancer Diagnostics
… XRD measurements in a single snapshot, while a coded aperture is placed between imaged objects and detector, enabling XRD spectra for individual pixels along the fan beam extent to be recovered from the multiplexed measurement. Simulations were used to identify a suitable geometry for the …
-
Design and Qualification of a Coded Aperture Cycloidal Mass Spectrometer to Detect Perfluorocarbon Tracer Molecules for Environmental Applications
… PFC detection method is required. A cycloidal coded aperture miniature mass spectrometers (C-CAMMS) could be such a method due to its integration of three core technologies that help to overcome the throughput versus resolution tradeoff that has historically hampered the miniaturization of mass …
-
X-ray Coherent Scatter Imaging for Intra-operative Margin Detection in Breast Conserving Surgeries
… coherent scatter computed tomography (CSCT) and coded aperture coherent scatter spectral imaging (CACSSI) for cancerous voxel detection and for intra-operative margin detection using (virtual) clinical trials. Finally, we experimentally implement a CACSSI system and determine its accuracy in …