Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 9 of 9 for “"coherent sampling"”.
-
Relaxing the requirements for accurate spectral testing of data converters
… of the test signal and of the need to achieve coherent sampling. The standard test requires that the input signal linearity be about 20dB more pure than the ADC under test along with always maintaining coherent sampling. This algorithm will reduce the purity requirement by allowing the test …
-
Accurate and robust spectral testing with relaxed instrumentation requirements
… testing. The first method targets the non-coherent sampling issue on spectral testing, especially when the non-coherently sampled signal has large distortions. The second method resolves simultaneous amplitude and frequency drift with non-coherent sampling. The third method achieves …
-
Accurate spectral test algorithms with relaxed instrumentation requirements
… method, which eliminates the requirement of coherent sampling when using the DFT for testing the spectral response of an ADC. The robustness and accuracy of the proposed FIRE method is verified using simulation and measurement results obtained with non-coherently sampled data.</p> <p>The …
-
High Accuracy Real-time GPS Synchronized Frequency Measurement Device for Wide-area Power Grid Monitoring
… and the optimized design of filters and a coherent sampling scheme to reduce or eliminate those impacts. The verification test results show that the frequency measurement accuracy of the FDR is within +/-0.0005Hz, and the time synchronization error is within +/-500ns with suitable GPS …
-
Sparsity-Aware Low-Power ADC Architecture with Advanced Reconstruction Algorithms
… (CS) technique enables a universal sub-Nyquist sampling of sparse and compressible signals, while still guaranteeing the reliable signal recovery. Its potential lies in the reduced analog-to-digital conversion rate in sampling broadband and/or multi-channel sparse signals, where conventional …
-
Accurate spectral testing without accurate instrumentation
… relaxing the requirements on precise control of coherent sampling and input signal amplitude. The efficiency and accuracy of this method is similar to the straightforward FFT, but it can simultaneously handle amplitude clipping and noncoherent sampling. By replacing a noncoherent and clipped …
-
Modelování tlakových pulsací v kapalině s vlivem druhé viskozity
Práce má za cíl stanovit hodnotu rychlosti zvuku a druhé dynamické viskozity tekutiny s využitím numerické optimalizace analytického modelu. Teoreticky lze rychlost zvuku a druhou viskozitu stanovit ze tří naměřených tlakových průběhů v čase po délce trubice, rychlost zvuku se přitom dohledává pro …
-
Tlumení tlakových pulzací a snižování hluku v potrubních systémech
Hlavním cílem této práce je řešení tlakových pulzací v potrubním systému s dynamickým tlumičem. Je představena vlastní geometrie laděné odbočky, která je zkoumána za pomoci vytvořeného matematického modelu, numerických simulací a výsledky jsou také ověřeny experimentálně. V odvozených řídících …
-
Development of laser spectroscopy for scattering media applications
Laser spectroscopy for both large and small spatial scales has been developed and used in various applications ranging from remote monitoring of atmospheric mercury in Spain to investigation of oxygen contents in wood, human sinuses, fruit, and pharmaceutical solids. Historically, the lidar group …