Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"coil dimensions"”.

  1. An Electromagnetic Field Model For The Design Of RF Reed Relays

    … electrostatic characteristics and coil eddy current losses of a reed relay was developed. These characteristics were returned from reed and coil dimensions. The model was intended as an aid to the design of reed relays for Radio Frequency (RF) and high voltage applications. An …

    plymouth Repository record for An Electromagnetic Field Model For The Design Of RF Reed Relays (opens in a new tab)

  2. Solution properties of polymers in ionic liquids

    … PEO in an IL by measuring the dependence of PEO coil size on polymer molecular weight. Since this system is not viable in light scattering, small-angle neutron scattering (SANS) was utilized instead. Therefore, a wide range of accessible molecular weights (10 to 250 kg/mol) of perdeuterated …

    umn Repository record for Solution properties of polymers in ionic liquids (opens in a new tab)

  3. Transport Phenomena in Oscillatory Flow Mini Coils for Solid-Forming Reactions

    … on the intensification and characterization of a coil reactor capable of handling solid-forming reactions and potentially applicable to pharmaceutical industries. This type of reactor has been partially intensified as its flow is continuous, and its volume reduced relative to batch-wise operation. …

    ottawa-retro Repository record for Transport Phenomena in Oscillatory Flow Mini Coils for Solid-Forming Reactions (opens in a new tab)

  4. Using Heat Effects on Coil Hydrodynamic Size to Reveal the Nature and Energetics of Denatured State Conformational Bias

    … proteins (IDPs) and the impact of heat on the coil dimensions, demonstrating that the sequence dependence and thermodynamic energies associated with intrinsic biases for the α and polyproline II (PPII) backbone conformations can be obtained. This result was determined by using a model of the …

    texas-state Repository record for Using Heat Effects on Coil Hydrodynamic Size to Reveal the Nature and Energetics of Denatured State Conformational Bias (opens in a new tab)

  5. A high temperature pressure sensor based on magnetic coupling and silicon wafer bonding

    … components within the sensor are two inductive coils, a silicon diaphragm and a hermetic vacuum cavity. The modeling based on a nine-turn single level coil device and a 300 um x 300 diaphragm indicates an output rms voltage range of 70 mV with an input current of 100 mA and frequency of 200 MHz …

    njit Repository record for A high temperature pressure sensor based on magnetic coupling and silicon wafer bonding (opens in a new tab)

  6. Wireless power transfer using resonant inductive coupling - Design and implementation of an IPT system with one meter air gap in the region between near-range and mid-range

    … of at least one sending and one receiving coil which resonates to make the circuit appear resistive, thus decreasing the reactive power in the system and increasing the active power transfer. The IPT system can be classified to be either near-range or mid-range. Mid-range is when the …

    chalmers Repository record for Wireless power transfer using resonant inductive coupling - Design and implementation of an IPT system with one meter air gap in the region between near-range and mid-range (opens in a new tab)

  7. Diffusion effects in eddy current nondestructive evaluation

    … eddy current NDE the transducer is an inductive coil or some combination of coils with an electromagnetic induction field surrounding the coil. The coil is used predominantly for surface or near-surface inspection of electrical conductors (metals). The change of impedance of the coil at its …

    iastate Repository record for Diffusion effects in eddy current nondestructive evaluation (opens in a new tab)

  8. New Methods and Applications in Nuclear Magnetic Resonance Microscopy using small RF Coils

    … miniaturization of the radiofrequency (RF) coil leading to a so-called microcoil is necessary; it also brings along detrimental effects. Therefore, there is a high potential for optimizing present MRM methods. Hence it is the aim of this work to improve and further develop present methods in …

    wurz-thes Repository record for New Methods and Applications in Nuclear Magnetic Resonance Microscopy using small RF Coils (opens in a new tab)

  9. Design, Implementation, and Control of a Magnetic Levitated Planar Motor

    … electromagnetic design with stationary square coil arrays and a 2D Halbach array mover. With this electromagnetic design, two platforms are fabricated and tetsed, the maglev test bench and the maglev floor. The maglev test bench is a 64-coil platform with a levitation area of 0.6 m by 0.6 m, …

    waterloo Repository record for Design, Implementation, and Control of a Magnetic Levitated Planar Motor (opens in a new tab)

  10. Βελτιστοποίηση σχεδιασμού συστημάτων υπεραγώγιμης μαγνητικής αποθήκευσης ενέργειας

    … applications. Additionally, superconducting coils and magnets—critical components of SMES systems—are examined. The chapter concludes by defining the study’s objectives, its contribution to the field, and the methodology followed. The second chapter presents a systematic literature review on …

    greece Repository record for Βελτιστοποίηση σχεδιασμού συστημάτων υπεραγώγιμης μαγνητικής αποθήκευσης ενέργειας (opens in a new tab)

  11. Hyaluronic Acid Interactions With Cell Surface Receptors - Understanding Cell Binding and Internalization of a Popular Biomaterial

    … rigidity and high molecular weight make the HA’s coil dimensions excessively large and therefore HA incorporates a very large number of water molecules within its coil. This is a massive hurdle for molecular dynamics simulations, leading to the common use of short oligosaccharides instead of a …

    the-open-u Download PDF for Hyaluronic Acid Interactions With Cell Surface Receptors - Understanding Cell Binding and Internalization of a Popular Biomaterial (opens in a new tab)