Showing 1 to 9 of 9 for “"coincidence system"”.
-
Design and Testing of a Coincidence System
… with the design, testing and performance of a coincidence system, the proposed North Texas State College accelerator.
-
A TECHNIQUE FOR MEASURING THE TIME RESPONSE AND THROUGH-PUT DELAY OF NEUTRON TIME-OF-FLIGHT (nTOF) SCINTILLATION DETECTORS USING COSMIC RADIATION IN A COINCIDENCE SYSTEM
… delay. Two plastic scintillator detectors in a coincidence system can detect an incident cosmic ray. If a third nTOF detector is placed between these coincident detectors, the output cosmic ray signal in the nTOF detector can be analyzed to produce the time response and through-put delay. …
-
Digital gamma-gamma coincidence measurements for neutron activation analysis
… the use of an advanced digital gamma-gamma coincidence system, XIA Pixie-16, for use in neutron activation analysis. The reason for performing this research is that, although gamma-gamma coincidence in NAA is not a new area of research, there has not been a comprehensive study of the use of …
-
Lifetimes of Excited States of Nuclei in the Mass Range 28<A<56 by Delayed Coincidence
… been performed. Using a high resolution delayed coincidence system and specially developed calibration and data analysis techniques, lifetime measurements have been made for low energy transitions in 28Al, 32P, 40K, 46Sc, 52v and 56Mn. A theoretical model which uses the static magnetic dipole …
-
Positron annihilation in the alkali halides
… the generation of the high pressures, a fastslow coincidence system for the lifetime spectra and a Ge(Li) detector to measure the doppler broadening of the.511 Mev. annihilation line. An attempt is made to correlate the results of the high pressure work on NaCl with the behavior of vacancies …
-
Beta and gamma ray spectroscopic analysis of the radiations emitted in the decay of selenium 75
… for eight transitions were obtained. In addition coincidence techniques employing a slow- fast coincidence system (resolving time 10⁻⁷ sec) were used to measure gamma-gamma coincidences, conversion electron-gamma coincidences and gamma-gamma directional correlations. A one hundred channel …
-
Characterization of ²³⁹Pu with coincidence and anticoincidence methods
Coincidence and anticoincidence techniques, including gamma-gamma coincidence and Compton suppression, have been used to effectively characterize many isotopes. However, these methods have not been thoroughly applied for ²³⁹Pu determination. Since this isotope has several low intensity gamma rays …
-
Preliminary evaluation of X-ray fluorescence imaging and ultra-high resolution CdTe PET: the progression toward broader spectrum multi-modality tools for small animal neuroscientific investigation
… applications. The two independent experimental systems were evaluated for proof of concept in order establish the potential viability of imaging small transgenic animals. The first modality, a benchtop XFET system, used an incident monochromatic 17.4 keV beam with a slit mounted Andor Ikon-L …
-
Studies in the technique of short time measurement and its application to nuclear isomerism
… this thesis was concerned with the use of a fast coincidence measuring system, i.e. an apparatus using scintillation counters for the measurement of short time intervals between nuclear radiations. The results deal partly with the technique itself and partly with its application to the study of …