Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"column base"”.

  1. Column base plate under eccentric loading

    … of the strength and deformational behavior of column base plates is of paramount importance in the analysis and design of pipe and pressure vessel supports. Both elastic and plastic stress analyses, using ANSYS computer program to simulate the strength and deformation of column base plates …

    njit Repository record for Column base plate under eccentric loading (opens in a new tab)

  2. Influence of Column-Base Fixity On Lateral Drift of Gable Frames

    … which assumes pinned connections at the base. The pinned connections provide no moment at the base and have zero rotational stiffness. However, in reality every connection provides some restraint and has some rotational stiffness. Hence, by considering a modeling assumption of pinned …

    vt Repository record for Influence of Column-Base Fixity On Lateral Drift of Gable Frames (opens in a new tab)

  3. Moment-Rotation Behavior of “Pinned” Column Base-Plate Connections in Low-Rise Metal Buildings

    … the design of low-rise metal building systems, column base connections are commonly modeled as pinned supports with no rotational stiffness for both serviceability and strength limit states. However, past studies have indicated that base connections, which are designed as pinned supports, …

    houston Repository record for Moment-Rotation Behavior of “Pinned” Column Base-Plate Connections in Low-Rise Metal Buildings (opens in a new tab)

  4. Advancing Cold-Formed Steel Portal Frame Design: An In-Depth Study of Seamed Box Sections, Eaves Connections, and Column Base Details

    … integrity. Additionally, two design approaches based on the Direct Strength Method (DSM) were developed to determine flexural-torsional buckling moments, enhancing the accuracy of bending capacity calculations. 2. Eaves Joint of CFS Portal Frames: This study involves experimental and finite …

    auckland-ms Repository record for Advancing Cold-Formed Steel Portal Frame Design: An In-Depth Study of Seamed Box Sections, Eaves Connections, and Column Base Details (opens in a new tab)

  5. The Seismic Performance of Steel-Framed Gravity System Column Bases

    Numerous studies have shown that gravity column base-plate connections are significantly stiffer than currently considered in design, to a point where they may cause detrimental effects to the connected column. To this end, this thesis aims to determine the realistic rotational stiffness of …

    auckland-ms Repository record for The Seismic Performance of Steel-Framed Gravity System Column Bases (opens in a new tab)

  6. Assessment of Analytical Procedures for Designing Metal Buildings for Wind Drift Serviceability

    … simplicity of analysis and design, connection at base of column is considered as pinned which provides no rotational restraint. The actual behavior of the connection however, is partially rigid, that provides some rotational stiffness even in case of single row of bolts. Moreover, using a …

    vt Repository record for Assessment of Analytical Procedures for Designing Metal Buildings for Wind Drift Serviceability (opens in a new tab)

  7. Structural Optimization using the Principle of Virtual Work and an Analytical Study on Metal Buildings

    … understanding the behavior of structural systems based on the principle of virtual work was developed by Dr. Finley Charney in the early 1990s. The program was called DISPAR, which stands for DISplacement PARticipation factors, and was written to work in accordance with SAP90 and ETABS. This …

    vt Repository record for Structural Optimization using the Principle of Virtual Work and an Analytical Study on Metal Buildings (opens in a new tab)

  8. MOMENT-ROTATION BEHAVIOR OF BASE-PLATE CONNECTIONS IN LOW-RISE METAL BUILDINGS

    In designing low-rise metal building systems, column-base connections are commonly assumed to be pinned with no rotational stiffness for both serviceability and strength limit states; however, practical experience indicates that even base connections that are designed to be pinned have a …

    houston Repository record for MOMENT-ROTATION BEHAVIOR OF BASE-PLATE CONNECTIONS IN LOW-RISE METAL BUILDINGS (opens in a new tab)

  9. Numerical Modelling of Exposed Base Plate Connections and Their Influence on System-level Seismic Response

    Gravity columns with exposed base plate connections are often assumed as pinned in both analysis and design. However, past experiments have shown that base plate connections can provide a significant level of flexural strength and stiffness. This study investigates the influence that the effect of …

    queens Repository record for Numerical Modelling of Exposed Base Plate Connections and Their Influence on System-level Seismic Response (opens in a new tab)

  10. Rotational Strength and Stiffness of Shallowly Embedded Base Connections in Steel Moment Frames

    Shallowly embedded column base connections with unreinforced block out concrete are a common method of connecting steel columns to their foundation. There has been little research done to accurately quantify the effects of this block out concrete on the connection strength and rigidity, and …

    byu Repository record for Rotational Strength and Stiffness of Shallowly Embedded Base Connections in Steel Moment Frames (opens in a new tab) Download PDF for Rotational Strength and Stiffness of Shallowly Embedded Base Connections in Steel Moment Frames (opens in a new tab)

  11. Design of One-Story Hollow Structural Section (HSS) Columns Subjected to Large Seismic Drift

    During an earthquake, columns in a one-story building must support vertical gravity loads while undergoing large lateral drifts associated with deflections of the vertical seismic force resisting system and deflections of the flexible roof diaphragm. Analyzing the behavior of these gravity columns …

    vt Repository record for Design of One-Story Hollow Structural Section (HSS) Columns Subjected to Large Seismic Drift (opens in a new tab)

  12. Evaluation of soil-structure interaction effects in the dynamic response of instrumented bridges based on seismic records

    … of a bridge –i.e. the bridge deck, pier base, and free field– were conducted. A total of 6 instrumented bridges subjected to 12 earthquakes were selected for the analysis, focusing on the behavior in the transverse direction for these particular cases. The first step of the evaluation …

    ubc Repository record for Evaluation of soil-structure interaction effects in the dynamic response of instrumented bridges based on seismic records (opens in a new tab) Download PDF for Evaluation of soil-structure interaction effects in the dynamic response of instrumented bridges based on seismic records (opens in a new tab)

  13. Initial Investigation of Connection Behavior for Buckling-Restrained Braces (BRBs) in Precast Concrete Frames

    … implied that there is some change in column base fixity as the frame undergoes larger horizontal displacements. The simplistic finite element model tuned column base stiffness and showed an increase in stiffness as a potential cause for this deviation. This thesis concludes by …

    clemson Repository record for Initial Investigation of Connection Behavior for Buckling-Restrained Braces (BRBs) in Precast Concrete Frames (opens in a new tab)

  14. Seismic Performance of Yielding Columns Supported by Rocking Foundations: A Computational Study

    … interaction model. While both fixed base and rocking foundation systems performed satisfactorily during relatively small shaking events, rocking foundation systems exhibited superior performance during strong shaking events. Furthermore, rocking foundation design reduced the peak deck …

    ndsu Repository record for Seismic Performance of Yielding Columns Supported by Rocking Foundations: A Computational Study (opens in a new tab)

  15. Cyclic Behavior of a Hybrid Light Gauge and HSS Mezzanine Structural System

    … beams connected to hollow structural steel (HSS) columns cap plates using wedge expansion anchors at the base plate to generate rotation restraint, is performed in this research. The characteristics of the structure will be explained by displaying full experimental results of structural testing. …

    marquette Repository record for Cyclic Behavior of a Hybrid Light Gauge and HSS Mezzanine Structural System (opens in a new tab)

  16. The behaviour and design of demountable connections to promote the reduction and reuse of structural steel in steel and composite buildings

    … and performance of the conventional steel column connections under various loading conditions through the developed finite element model, with which the accuracy of the behaviour prediction for the steel column connections can be significantly improved. The concept of demountability of …

    unsw Repository record for The behaviour and design of demountable connections to promote the reduction and reuse of structural steel in steel and composite buildings (opens in a new tab)

  17. Analysis and Design of Semi-Continuous Sway and Non-Sway Frames

    … set of analyses the connection stiffness and column base stiffnesses were changed, by making changes to the M-φ curve. It could then be seen how the joint stiffnesses affect the flexibility and strength of the frame. The model was then expanded to model multi-storey construction. Analysis …

    soton Download PDF for Analysis and Design of Semi-Continuous Sway and Non-Sway Frames (opens in a new tab)

  18. Self-Centering Steel Plate Shear Walls: Subassembly and Full-Scale Testing

    … web plates, that are connected to the beams and columns. During lateral sway, the web plate resists lateral load through the development of tension field action, and energy is dissipated through ductile yielding of the plate. Unlike conventional steel plate shear walls, the boundary frame in the …

    washington Repository record for Self-Centering Steel Plate Shear Walls: Subassembly and Full-Scale Testing (opens in a new tab)

  19. Towards a Better Understanding of the Fundamental Period of Metal Building Systems

    … to exhibit signs of fixed conditions at the column base. This assertion was corroborated by updating the analytical models. The two modeling approaches showed good agreement with each other as well, validating the use of planar models to predict the period. Finally, new predictive equations …

    vt Repository record for Towards a Better Understanding of the Fundamental Period of Metal Building Systems (opens in a new tab)

Page 1 of 3