Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 58 for “"column length"”.

  1. Optimum design in continuous chromatography

    … problem is stated and solved. The optimum column length and angular velocity are defined through two separation factors, longitudinal dispersion coefficient and other design parameters. The first optimization problem is then generalized and solved to yield a performance chart for binary …

    rice Repository record for Optimum design in continuous chromatography (opens in a new tab)

  2. Analysis of Capillary Flow in Interior Corners : Perturbed Power Law Similarity Solutions

    … fluid advances along the corner measured by the column length z = L(t), which is governed by a nonlinear partial differential equation with dynamical boundary conditions. Three flow types are examined: capillary rise, spreading drop, and tapered corner. The spreading drop regime is shown to …

    portland-state Repository record for Analysis of Capillary Flow in Interior Corners : Perturbed Power Law Similarity Solutions (opens in a new tab)

  3. The determination of isothermal adsorption equilibrium parameters, dispersion and mass transfer coefficients for a packed bed

    … the first moment. The effects of flow rate and column length were evaluated. Higher flow rates caused a sharper pulse curve and longer column length caused a broader pulse curve. The effectiveness of moment analysis for resolving a simple system has been demonstrated.</p>

    ut-knoxville Repository record for The determination of isothermal adsorption equilibrium parameters, dispersion and mass transfer coefficients for a packed bed (opens in a new tab)

  4. Investigation of column and instrumental parameters for fast gas chromatography analysis

    … actually being spent on the analysis. Capillary columns are known to be very efficient due to the long lengths and thin stationary phase films. However, analysis can be done much faster if shorter column lengths and thinner stationary phases are used because the retention time is a function of …

    vt Repository record for Investigation of column and instrumental parameters for fast gas chromatography analysis (opens in a new tab)

  5. DNA restriction fragment analysis using size-selective capillary electrophoresis with laser induced fluorescence detection

    … separation and instrumental concerns. On-column complexation using intercalation dyes with laser fluorometric detection provides sensitive detection of DNA restriction fragments. This is accomplished by the addition of the dye to CE running buffer and employing an inexpensive He-Ne laser …

    utk-theses Repository record for DNA restriction fragment analysis using size-selective capillary electrophoresis with laser induced fluorescence detection (opens in a new tab)

  6. Novel Chromatographic Separations Through Dynamically Controlled Stationary Phase Removal

    … Here, the temperature is varied along the length of the column so that the stationary phase can be maintained on a section of the column, while other areas are left uncoated. Therefore, the effective column length can be changed by adjusting the thermal gradient. The length of the column is …

    calgary Repository record for Novel Chromatographic Separations Through Dynamically Controlled Stationary Phase Removal (opens in a new tab)

  7. Experimental Studies in Temperature Programmed Gas Chromatography

    … Comparison of these effects was made by studying column length and linear velocity in conjunction with temperature programming rates. Experimental determinations using a combination of three different column lengths, five linear velocities and three ramping rates on a three-component sample were …

    vt Repository record for Experimental Studies in Temperature Programmed Gas Chromatography (opens in a new tab)

  8. Quantification of movement of Cryptolestes ferrugineus (Coleoptera: Laemophloeidae) adults in one-dimensional columns under different storage conditions in stored wheat

    … knowledge gaps in insect movement within grain columns, crucial for refining storage strategies, particularly regarding one of the economically impactful pests, the rusty grain beetle (Cryptolestes ferrugineus), infesting stored wheat in the Northern United States and Canada. The study analyzed …

    manitoba Repository record for Quantification of movement of Cryptolestes ferrugineus (Coleoptera: Laemophloeidae) adults in one-dimensional columns under different storage conditions in stored wheat (opens in a new tab)

  9. DEM Study of a Single Stone Column in a Clayey Stratum

    … directly considered in the design of aggregate columns. However, because the granular material friction angle is a fundamental design parameter used to estimate the bearing capacity of aggregate piers, these factors could play an important role in the mechanical behavior of isolated aggregate …

    arkansas Repository record for DEM Study of a Single Stone Column in a Clayey Stratum (opens in a new tab)

  10. High efficiency gas-solid chromatographic columns

    … two types of high efficiency gas chromatographic columns was conducted. The first type (micropacked) can be defined as columns having an internal diameter less than 1 mm and a particle/column diameter ratio between 0.1 and O.3 and a packing density comparable to conventional packed columns. The …

    vt Repository record for High efficiency gas-solid chromatographic columns (opens in a new tab)

  11. The Spanish Civil War as Carried by the <em>Milwaukee Leader</em> from July 18, 1936, to August 1, 1937

    … every issue containing war news was noted, the column length measured in inches, and a comparative chart graphed indicating relation­ ship between the amount of straight news, pictures and editorials. Supplementary charts show the incidence of war news over a thirteen month period, and …

    marquette Repository record for The Spanish Civil War as Carried by the <em>Milwaukee Leader</em> from July 18, 1936, to August 1, 1937 (opens in a new tab)

  12. Preparative high performance liquid chromatography

    … was developed and used to pack sixteen HPLC columns having different lengths and internal diameters with 10 µm Lichrosorb Sl-100. The evaluation of these columns led to several conclusions: the column efficiency, expressed in plates per meter, is a function of the ratio of column internal …

    vt Repository record for Preparative high performance liquid chromatography (opens in a new tab)

  13. The Development And Study Of Chelating Substrates For The Separation Of Metal Ions In Complex Sample Matrices

    … the separation of trace metals using a single column under both isocratic and gradient elutions were investigated. Neutral polystyrene based resins from a variety of manufacturers including a hypercrosslinked resin (MN 200) were functionalised via impregnation with chelating dyestuffs or …

    plymouth Repository record for The Development And Study Of Chelating Substrates For The Separation Of Metal Ions In Complex Sample Matrices (opens in a new tab)

  14. Preparative liquid chromatography : a study of the elution and displacement modes

    … production rate for component two at constant column length, particle size and flow rate is such that the band of component one interferes just enough with that of component two to reach the purity requirements (i.e. 99 % yield).</p>

    utk-theses Repository record for Preparative liquid chromatography : a study of the elution and displacement modes (opens in a new tab)

  15. Derivation and chromatographic separation of acid indole auxins

    … separation of these compounds, including column length, choice of liquid phase, and column temperature were studied and optimized. The effects of derivative storage were examined and optimum storage conditions, alone; with the stability of the primary reaction product, were determined. The …

    vt Repository record for Derivation and chromatographic separation of acid indole auxins (opens in a new tab)

  16. Enhancing gas chromatographic analysis: a novel cryo-enrichment module for GC analysis /

    … lowering the temperature of the chromatographic column to extremely low levels, this method reduces the volatility of compounds, leading to their efficient condensation onto the column's stationary phase. The primary focus of the thesis is the development of a custom cryo-enrichment module to …

    vilnius Repository record for Enhancing gas chromatographic analysis: a novel cryo-enrichment module for GC analysis / (opens in a new tab)

  17. Experimental Investigation of Plasma Dynamics in Jets and Bubbles Using a Compact Coaxial Plasma Gun in a Background Magnetized Plasma

    … current-driven plasma jet is formed. The plasma column experiences the current-driven kink instability consistent with the Kruskal-Shafranov criterion. When a perpendicular background magnetic field is applied, the jet column length increases with a longer lifetime and appears to show greater …

    unm Repository record for Experimental Investigation of Plasma Dynamics in Jets and Bubbles Using a Compact Coaxial Plasma Gun in a Background Magnetized Plasma (opens in a new tab)

  18. Development of strategies for biochemical analysis using capillary electrophoresis

    … fragment size, soluble polymer concentration and column length was undertaken. These models allowed for the optimal separation performance of all fragments in the sample. The development of a capillary-based assay for the investigation of protein-DNA interactions was also explored. Resolution of …

    utk-theses Repository record for Development of strategies for biochemical analysis using capillary electrophoresis (opens in a new tab)

  19. The Fabrication And Study Of Metal Chelating Stationary Phases For The High Performance Separation Of Metal Ions

    … trace metals in complex samples, using a single column and isocratic elution, is described. Hydrophobic, neutral polystyrene divinylbenzene resins were either impregnated with chelating dyes or dynamically modified with heterocyclic organic acids, using physical adsorption and chemisorption …

    plymouth Repository record for The Fabrication And Study Of Metal Chelating Stationary Phases For The High Performance Separation Of Metal Ions (opens in a new tab)

Page 1 of 3