Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 65 for “"column system"”.

  1. Physiological studies on the postsynaptic dorsal column system

    … identified neurones of the postsynaptic dorsal column (p.s.d.c.) system and has examined aspects of the relationship between the neurones of this projection and the spinocervical tract (s.c.t.). Extracellular single unit microelectrode recordings were made from the axons of p.s.d.c. neurones …

    edinburgh Repository record for Physiological studies on the postsynaptic dorsal column system (opens in a new tab)

  2. Dispersion and retardation of contaminants in a high pressure liquid chromatography soil column system

    … high-pressure/high-flow rate soil chromatography system as a protocol method for the rapid screening of chemicals in natural, undisturbed aquifer samples is proposed. A mathematical advective-dispersive transport model was applied which evaluated the soil column and apparatus as a two-layered …

    rice Repository record for Dispersion and retardation of contaminants in a high pressure liquid chromatography soil column system (opens in a new tab)

  3. A computer program for the optimization of binary distillation in a dual-column system

    … is presented for the optimization of a two-column distillation system involving a two-component mixture. The economic reflux ratios in each column are determined using the McCabe-Thiele Method. Activity coefficients are computed by either the Wilson equation, the Margules equation, or both. …

    njit Repository record for A computer program for the optimization of binary distillation in a dual-column system (opens in a new tab)

  4. Effects of multiple bacterial species and nutrient injection on phenanthrene transport and bacterial cell elution

    … cell elution, and cell distribution within a column system. Three indigenous, phenanthrene degrading species, Actinobacter junii, Pseudamonas oleovorans, and Methylbacterium sp., were used. Characterization studies were conducted to determine the relative cell yield and cell hydrophobicity. …

    arizona-thes Repository record for Effects of multiple bacterial species and nutrient injection on phenanthrene transport and bacterial cell elution (opens in a new tab)

  5. The integration of Dow's Fire and Explosion Index into process design and optimization to achieve an inherently safer design

    … by applying it into reactor-distillation column system. The final result is the optimum economic and inherently safer design for the reactor and distillation column system.

    tamu Repository record for The integration of Dow's Fire and Explosion Index into process design and optimization to achieve an inherently safer design (opens in a new tab)

  6. Application of GAC adsorption in pulp and paper mill effluent treatment.

    … carbon (GAC) adsorption using fixed-bed columns in the post-treatment of the whole-plant effluent of a Kraft and fine paper manufacturer. A mathematical model, the branched pore or dual rate model, was used to simulate the GAC column adsorption process. The computer program PRECOS was …

    ottawa-retro Repository record for Application of GAC adsorption in pulp and paper mill effluent treatment. (opens in a new tab)

  7. Investigating chlorite dismutase biocatalyst reuse using columns

    … costs for continuously operated water treatment systems. To study the potential for biocatalyst reuse, experiments were conducted on a chlorite dismutase biocatalyst modified with a strep tag; this reuse system allows the biocatalyst to bind to coated resin beads that can be reused in a column …

    uiuc Repository record for Investigating chlorite dismutase biocatalyst reuse using columns (opens in a new tab)

  8. Performance-based seismic design of post-tensioned concrete columns

    … Thus, developing a seismic resilient bridge system becomes a focus of researchers and practicing engineers. To achieve this goal, post-tensioned precast concrete columns in various forms are proposed by researchers. Yet no systematic studies cover various design parameters, which poses …

    ubc Repository record for Performance-based seismic design of post-tensioned concrete columns (opens in a new tab) Download PDF for Performance-based seismic design of post-tensioned concrete columns (opens in a new tab)

  9. An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation

    … process on protein separation.</p> <p>The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption method. The separation factors for …

    njit Repository record for An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation (opens in a new tab)

  10. Measurement of LDL Receptor Activity in HepG2 Cells Grown on Microcarrier Beads

    … monolayer culture in tissue culture dishes. This system permits the identification of substances that regulate the receptor activity but is limited as a research tool because substances secreted by the cells, such as bile acids and LDL itself, may cause feedback regulation of the pathway. This …

    the-open-u Download PDF for Measurement of LDL Receptor Activity in HepG2 Cells Grown on Microcarrier Beads (opens in a new tab)

  11. Detection of Biologically Important Molecules

    Anions play important roles in biological systems. The design of anion sensors has been of great interest. The selective detection of a specific anion is particularly challenging. In the first chapter, I describe the synthesis of a TBS-protected fluorescein dye (1.1) and its use for the selective …

    lsu-thes Repository record for Detection of Biologically Important Molecules (opens in a new tab)

  12. Laboratory Measurement of Electrical and Hydraulic Properties of Regolith Over Granitic Bedrock

    … order to evaluate this hypothesis, a novel soil column system has been built to measure the electrical and hydrological properties of soils at both saturated and unsaturated conditions. For saturated tests, the soil column system mirrors that of a constant-head setup for permeability tests. The …

    boise Repository record for Laboratory Measurement of Electrical and Hydraulic Properties of Regolith Over Granitic Bedrock (opens in a new tab)

  13. Retrofitting industrial, conventional column systems to petyluk/divided wall columns

    … and requires significant energy inputs. Petyluk column (also known as Fully Thermally Coupled Distillation System, FTCDS) is chosen for this study due to its lower energy consumption compared to the conventional column system. Its implementation in terms of the equivalent, Divided Wall Column …

    nus Repository record for Retrofitting industrial, conventional column systems to petyluk/divided wall columns (opens in a new tab) Download file for Retrofitting industrial, conventional column systems to petyluk/divided wall columns (opens in a new tab)

  14. LabVIEW Improvements and Equipment Redesign of Unit Operations Distillation Column

    … to create a program to control the distillation column from startup to shutdown. Improvements were made to both the distillation process equipment and the LabVIEW code to create a more interactive lab experience, enhance students’ conceptual understanding of distillation, and prepare students for …

    louisville Repository record for LabVIEW Improvements and Equipment Redesign of Unit Operations Distillation Column (opens in a new tab)

  15. Removal of the fermentation inhibitor, furfural, using activated carbon in cellulosic -ethanol production

    … and the sorbents were regenerated in a fixed-bed column system using ethanol-containing liquid from fermentation. The results were stable after running 20 times of sorption/desorption cycle.

    gatech Repository record for Removal of the fermentation inhibitor, furfural, using activated carbon in cellulosic -ethanol production (opens in a new tab)

  16. A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings

    Slab-column systems are commonly used as the gravity system of reinforced concrete buildings in high seismic regions. These systems are economical and typically constructed using stud rails at the reinforcement for the slab-column connection. However, prior work indicates that these connections are …

    washington Repository record for A RC Slab to CFT Column Connection for Improved Seismic Behavior of Multi-Story Buildings (opens in a new tab)

  17. Matrizes poliméricas puras e modificadas para adsorção do gás sulfeto de hidrogênio

    … tests were through a continuous flow of H2S in a column system (fixed bed reactor) adsorption on a laboratory scale. The techniques used to characterize the adsorbents were Infrared spectroscopy (FTIR), thermogravimetry analysis (TGA), X-ray fluorescence (XRF), the X-ray diffraction (XRD) electron …

    brazil-ufrn Repository record for Matrizes poliméricas puras e modificadas para adsorção do gás sulfeto de hidrogênio (opens in a new tab)

  18. Mechanical Behavior of Hybrid Concrete-Filled Fiber Reinforced Polymer Tube Columns

    … utilization of novel high performance structural systems. One such technology, the concrete-filled fiber reinforced polymer (FRP) tube (CFFT) system has been extensively studied the past few decades as an alternative design for bridge columns. This column system greatly simplifies construction by …

    uconn-diss Repository record for Mechanical Behavior of Hybrid Concrete-Filled Fiber Reinforced Polymer Tube Columns (opens in a new tab)

  19. Removal of iron by ion exchange from copper electrowinning electrolyte solutions containing antimony and bismuth

    … implemented in tandem with an iron ion exchange system. Additionally, preliminary calculations suggest that a system with a single ion exchange column may have difficulty removing sufficient iron for the CRED design conditions. Therefore, consideration should be given to the possibility of …

    ubc Repository record for Removal of iron by ion exchange from copper electrowinning electrolyte solutions containing antimony and bismuth (opens in a new tab) Download PDF for Removal of iron by ion exchange from copper electrowinning electrolyte solutions containing antimony and bismuth (opens in a new tab)

Page 1 of 4