Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 31 for “"common mode rejection ratio"”.
-
Analysis and Modification of an Electro-Oculometer
… by a parabolic filter. The amplifier has high common mode rejection ratio, low drift, and low input bias current. Both DC and AC analyses of the electro-oculometer have been performed. The common mode rejection ratio (CMRR) of the input stage of the device is computed both at low and high …
-
An investigation of series LC resonant circuits within a sleeve balun to achieve wideband operation
… bazooka balun or quarter-wavelength balun, are commonly used in antenna measurements. In general, baluns do perform well, but their performance is band-limited. Hence, for wider frequency bands, multiple baluns with different operating frequencies have to be used. This presents a major problem, …
-
Design of a low noise high common made rejection instrumentation amplifier
… for improvement. One general configuration is then analyzed in detail and methods for improvement are enumerated.</p><p>An improved amplifier circuit is described and analyzed with respect to common mode rejection and noise. Experimental data are presented showing good agreement …
-
An Ultra-Low Noise, Fully Differential Active Reset CMOS Imager with Transistor Based Column Parallel Common Mode Feedback for Spectrally Constructed Background Illumination Rejection
… CMOS imager for background illumination rejection is presented. Fabricated by TSMC35 technology, the pixel is able to detect very low light signals and discern them from backgrounds exceeding their intensity. Measurements indicate a common mode rejection ratio (81.6 dB), very high …
-
Hardware for an electrical machines laboratory computer data acquisition system
… system are studied and a system configuration proposed. Transducers for measuring voltage and current waveforms on a machine are considered and designed. The performance of the transducers constructed is evaluated in two sets of measurements. In the first set, measurement error, offset …
-
Generalized impedance converter (GIC) filter utilizing composite amplifier
… GIC filter chip fabrication. A composite operational amplifier utilizing the BiCMOS standard operational amplifier that was designed and introduced in a previous thesis is presented and its improved performance is investigated. The composite amplifier (C20A2) is designed using Silvaco EXPERT …
-
Wideband active MMIC baluns -concepts and design
… that can provide signal gain and a wide operational bandwidth. This work investigates three active balun designs operating between 2-18 GHz in 0.25 μm GaAs technology. The results are obtained from simulations in Keysight Advanced Design System using the UMS PH25-20 v.1.3.1 process design …
-
A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition
… generally weak and in the presence of stronger common mode signals. The INA thus needs to have very good Common Mode Rejection Ratio (CMRR) to amplify the weak biopotential while rejecting the stronger common mode interferers. Opamp based INAs with a resistor-capacitor feedback are suitable for …
-
A Low Power Low Noise Instrumentation Amplifier For ECG Recording Applications
… of the ECG system like the noise and common mode rejection ratio (CMRR). The extremely low ECG signal bandwidth also makes it difficult to achieve a fully integrated system. In this thesis, a fully integrated IA topology is presented that achieves low noise levels and low power …
-
Resources for Integrated Quantum Sensing in the Mid-infrared
… conversion efficiency of 57% at 2.07 μm, and a common-mode rejection ratio of 48 dB at 39.2 MHz.<br/><br/>We then utilise a silicon chip to implement an all-optical noise suppression<br/>scheme aimed at reducing the intensity noise of state-of-the-art pulsed lasers in this band via nonlinear …
-
High common-mode-noise-rejecting magnetic gradiometer for biomagnetic measurements
… focus on developing and characterising a high common-mode-noise-rejecting magneticgradiometer based on optically pumped magnetometers (OPMs). The work is motivated by the need to measure extremely weak magnetic signals, such as those produced by the heart and brain, which are often masked by …
-
Application of network transposition in the design of OTA-C filters and oscillators
… signal processing have shown that the current-mode approach is superior to the voltage-mode in terms of its wide bandwidth, high speed, low voltage and power. As a wide range of voltage-mode analogue circuits already exist, a straightforward method of converting these voltage-mode circuits to …
-
Transimpedance amplifier design using 0.18 um CMOS technology
… offers the potential for higher levels of integration since the analog circuits can be integrated with digital electronics on the same substrate. A 2.5 Gbps transimpedance amplifier fabricated using 0.18 um CMOS technology is presented. The TIA uses a shunt-shunt feedback topology with a cascode …
-
An analog approach to interference suppression in ultra-wideband receivers
… in the presense of such interference. The Operational Transconductance Amplifier (OTA) is the predominant building block in the design of the notch filter. In many cases, OTAs must handle input signals with large common mode swings. A new scheme for achieving rail-to-rail input to an OTA is …
-
High-Isolation Low-Power Active Quasi-Circulator for 44GHz Transceiver with Power and Noise Optimization in 0.18 Micrometer BICMOS
… of antenna from transmitter to receiver. As modern trend of wireless communication, conventional ferrite circulator is huge, bulky and heavy to be integrated with analog and digital baseband processing circuits. Active circulators provide a compact high isolation solution for low power …
-
INVESTIGATION OF TECHNIQUES FOR REDUCING UNINTENTIONAL ELECTROMAGNETIC EMISSIONS FROM ELECTRONIC CIRCUITS AND SYSTEMS
… the application of imbalance difference model to various circuit board and cable geometries, and balanced cable interface for reducing common-mode currents from power inverter. The first chapter discusses the importance and the meaning of the connection inductance associated with MLCCs …
-
Low-Noise Micro-Power Amplifiers for Biosignal Acquisition
… wearable/implantable systems, the low-power operation of the biopotential amplifier is critical to avoid thermal damage to surrounding tissues, preserve long battery life, and enable wirelessly-delivered or harvested energy supply. For an ideal thermal-noise-limited amplifier, the amplifier …
-
A 26 GHz Phase-Locked Loop Frequency Multiplier in 0.18-um CMOS
… of 4 and a fully differential topology for rejection of common mode interference signals. The PLL is composed of a voltage controlled oscillator (VCO), injection-locked frequency divider (ILFD) for the first divide-by-two stage, a static master-slave flip-flop (MSFF) divider for the second …
-
Novel approaches in current-feedback operational amplifier design
… bipolar junction transistor Current Feedback Operational Amplifier (CFOA) with a good Common-Mode Rejection Ratio (CMRR), suitable for radio frequency (RF) applications. This research focused on investigation of the established CFOA with the emphases of improving CMRR, bandwidth, Voltage-Offset …
-
Novel fibre-optic-based interferometric sensors exploiting coherent and low-coherence signal processing techniques
… source wavelength. The potential of using multi-mode laser diodes, as alternatives to the low coherence length sources such as LED' s or SLD ' s commonly used in 'white light' fibre-optic interferometric sensors has been studied. It is shown that the main advantage gained in using such sources is …
Page 1 of 2