Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 103 for “"common path"”

  1. Common-path interferometric sensing with resonant dielectric nanostructures

    … of my thesis. To this end, I have developed a common-path interferometric sensor based on guided-mode resonances to combine high performance with inherent stability. The concept of spatially superimposing two beams carrying the phase information of two orthogonally polarised resonant modes and …

    whiterose Repository record for Common-path interferometric sensing with resonant dielectric nanostructures (opens in a new tab)

  2. Measuring and calibrating non-common path aberrations in adaptive optics assisted image-slicer based spectrographs

    … the AO wavefront sensing and science optical paths, known as NonCommon Path Aberrations (NCPA). These aberrations, which primarily affect the spatial point spread function (PSF) in HARMONI, cannot be sensed directly due to the absence of phase information in focal plane intensity measurements, …

    oxford Repository record for Measuring and calibrating non-common path aberrations in adaptive optics assisted image-slicer based spectrographs (opens in a new tab)

  3. Speckle Reduction in an All Fiber Time Domain Common Path Optical Coherence Tomography by Frame Averaging

    … the Niris® 1300e Imaging System, an all fiber common path TDOCT system was used. We investigated the efficacy of simple frame averaging using non-living and tissue phantoms containing various sizes and distributions of scatterers that give rise to random noise or speckle. Signal to noise ratio …

    ohiolink Repository record for Speckle Reduction in an All Fiber Time Domain Common Path Optical Coherence Tomography by Frame Averaging (opens in a new tab)

  4. ULTRA-LOW-LEVEL ABSORPTION MEASUREMENT OF ION ASSISTED ELECTRON BEAM DEPOSITED OPTICAL THIN FILMS BY PHOTOTHERMAL COMMON-PATH INTERFEROMETRY

    … investigation is the utilization of photothermal common-path interferometry as the primary measurement technique to characterize the deposited thin films. The study initiates with the meticulous assembly and calibration of a specialized photothermal common-path interferometry setup whose …

    metu Repository record for ULTRA-LOW-LEVEL ABSORPTION MEASUREMENT OF ION ASSISTED ELECTRON BEAM DEPOSITED OPTICAL THIN FILMS BY PHOTOTHERMAL COMMON-PATH INTERFEROMETRY (opens in a new tab)

  5. In search of a Christian-Muslim common path from desacralization to desacralization of nature: Sallie McFague and Seyyed Hossein Nasr on the ecological crisis

    … differences, McFague and Nasr share profound common ground. They both understand the ecological crisis as a result of the desacralization of nature in human perception. They believe that Western Christianity's failure to cultivate a spiritual vision of nature set the stage for the development …

    bu Repository record for In search of a Christian-Muslim common path from desacralization to desacralization of nature: Sallie McFague and Seyyed Hossein Nasr on the ecological crisis (opens in a new tab)

  6. Tomographic imaging techniques using broadband polarized light for tissue diagnostics

    … polarimetry instrument(FOSPI) as readout of a common-path spectral interferometer with a broadband frequency swept laser source. The FOSPI is a PM fiber based instrument to measure the polarization state of collected light and incorporation of the FOSPI into a common-path spectral …

    texas Repository record for Tomographic imaging techniques using broadband polarized light for tissue diagnostics (opens in a new tab)

  7. Interferometric reflectance microscopy for physical and chemical characterization of biological nanoparticles

    … (iii) lack of chemical specificity. Advances in common-path interferometric microscopy have successfully overcome the weak contrast limitation and enabled direct detection of low-index biological nanoparticles down to single proteins. However, interferometric light microscopy does not overcome …

    bu Repository record for Interferometric reflectance microscopy for physical and chemical characterization of biological nanoparticles (opens in a new tab)

  8. High Space -Bandwidth Wavefront Sensing by Sampling and Spatial Multiplexing

    … to the output plane (space multiplexing), on a common optical path. The common path fan-out configuration makes the system compact and vibration-insensitive.

    uiuc Repository record for High Space -Bandwidth Wavefront Sensing by Sampling and Spatial Multiplexing (opens in a new tab)

  9. Intraoperative optical coherence tomography guided deep anterior lamellar keratoplasty

    … robotic surgical procedures for DALK. With the common-path design of the OCT system, the relative position of the surgical tool and the targeted tissue layer can be extracted to guide the robotic procedure in real time. Both swept-source and spectral-domain OCT based guidance systems have been …

    jhu Repository record for Intraoperative optical coherence tomography guided deep anterior lamellar keratoplasty (opens in a new tab)

  10. Sugerties nuostolių tyrimas optinėse dangose, panaudojant fototerminės interferometrijos metodą /

    … of surface absorption using the photothermal common-path interferometry (PCI) technique requires calibration samples made of investigative material. For this purpose, calibration samples of various substrate materials (glass and crystals) with a coated thin semi-transparent chromium layer were …

    vilnius Repository record for Sugerties nuostolių tyrimas optinėse dangose, panaudojant fototerminės interferometrijos metodą / (opens in a new tab)

  11. Image sharpening metrics and search strategies for indirect adaptive optics

    … considered here is the removal of so-called non-common path errors in a traditional adaptive optics system, which can otherwise degrade the system performance.

    durham Repository record for Image sharpening metrics and search strategies for indirect adaptive optics (opens in a new tab)

  12. The use of charge transfer device detectors and spatial interferometry for analytical spectroscopy.

    … interferometer system. The performance of a common path interferometer using a linear charge-coupled device detectors is presented and compared to conventional dispersive systems. The throughput, resolution, and other practical factors are discussed. The common path system has a much larger …

    arizona-thes Repository record for The use of charge transfer device detectors and spatial interferometry for analytical spectroscopy. (opens in a new tab)

  13. Persistent current and electron transport through ultra-thin networks

    … The probability of traversing through the common path by the electron can be controlled by the two applied fluxes. It shows that an electron traverses through the irreducible network with a fractional charge as manifested in the flux periodicity that is experimentally observable. The second …

    must-thes Repository record for Persistent current and electron transport through ultra-thin networks (opens in a new tab)

  14. CONVOLUTION PRODUCT INTERFEROMETER.

    A common path interferometer utilizing noncritically phase matched frequency doubling crystals is presented. The interference pattern is directly sensitive to the wavefront shape (like that of a Mach Zender) and is in the second harmonic of the laser source. This interferometer has twice the …

    arizona-thes Repository record for CONVOLUTION PRODUCT INTERFEROMETER. (opens in a new tab)

  15. Intraoperative Fourier domain optical coherence tomography for microsurgery guidance and assessment

    … plaque development. An all fiber-optic common-path optical coherence tomography (CP-OCT) system capable of measuring high-resolution optical distances, was built and integrated into di fferent imaging modalities. First, a novel non-contact accurate in-vitro intra-ocular lens power …

    jhu Repository record for Intraoperative Fourier domain optical coherence tomography for microsurgery guidance and assessment (opens in a new tab)

  16. INFRARED INTERFEROMETRIC SYSTEMS

    … in this work are the infrared laser unequal path interferometer (IRLUPI), the IRLUPI with infrared computer generated hologram (IRCGH), the infrared common path interferometers such as the infrared point diffraction interferometer (IRPDI), and the infrared scatterplate interferometer (IRSPI). …

    arizona-thes Repository record for INFRARED INTERFEROMETRIC SYSTEMS (opens in a new tab)

  17. Long paths and cycles in graphs with large minimum degree

    … several of these results. The study of long paths is related to the study of long cycles. In a graph in which every pair of vertices is connected by a long path, every edge lies on a long cycle. We prove that any set of four vertices lying on a common path in a 2-connected graph lie on a …

    fau Repository record for Long paths and cycles in graphs with large minimum degree (opens in a new tab)

  18. A search set model of path tracing in graphs

    Path tracing is a common task in many real world uses of graphs that display networks of relationships. Despite previous work in the evaluation of how factors, such as edge-edge crossings, impact the readability of graph layouts, what makes one path-tracing task more difficult than another is not …

    ubc Repository record for A search set model of path tracing in graphs (opens in a new tab)

  19. Dispersed reference interferometry for on-machine metrology

    … is introduced which makes use of miniature common-path probes linked by fibre to a remote interrogation interferometer allowing reduction in size of the on-machine metrology apparatus. Modifications to the DRI are described to enable this common-path remote fibre probing, along with changes …

    huddersfield Repository record for Dispersed reference interferometry for on-machine metrology (opens in a new tab)

  20. Compact phase imaging platform and its application to material science and manufacturing

    … quantitatively. Herein, the category of “common-path” techniques promises adaptable, compact, robust, and cost-efficient imaging devices, enabling use in industrial applications outside of a well-controlled lab environment. In this thesis, we will describe the development and technological …

    barcelona Repository record for Compact phase imaging platform and its application to material science and manufacturing (opens in a new tab)

Page 1 of 6