Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"common-mode rejection ratio"”.

  1. Analysis and Modification of an Electro-Oculometer

    … by a parabolic filter. The amplifier has high common mode rejection ratio, low drift, and low input bias current. Both DC and AC analyses of the electro-oculometer have been performed. The common mode rejection ratio (CMRR) of the input stage of the device is computed both at low and high …

    ucf Repository record for Analysis and Modification of an Electro-Oculometer (opens in a new tab)

  2. An investigation of series LC resonant circuits within a sleeve balun to achieve wideband operation

    … bazooka balun or quarter-wavelength balun, are commonly used in antenna measurements. In general, baluns do perform well, but their performance is band-limited. Hence, for wider frequency bands, multiple baluns with different operating frequencies have to be used. This presents a major problem, …

    uiuc Repository record for An investigation of series LC resonant circuits within a sleeve balun to achieve wideband operation (opens in a new tab)

  3. Design of a low noise high common made rejection instrumentation amplifier

    … for improvement. One general configuration is then analyzed in detail and methods for improvement are enumerated.</p><p>An improved amplifier circuit is described and analyzed with respect to common mode rejection and noise. Experimental data are presented showing good agreement …

    ut-knoxville Repository record for Design of a low noise high common made rejection instrumentation amplifier (opens in a new tab)

  4. An Ultra-Low Noise, Fully Differential Active Reset CMOS Imager with Transistor Based Column Parallel Common Mode Feedback for Spectrally Constructed Background Illumination Rejection

    … CMOS imager for background illumination rejection is presented. Fabricated by TSMC35 technology, the pixel is able to detect very low light signals and discern them from backgrounds exceeding their intensity. Measurements indicate a common mode rejection ratio (81.6 dB), very high …

    calgary Repository record for An Ultra-Low Noise, Fully Differential Active Reset CMOS Imager with Transistor Based Column Parallel Common Mode Feedback for Spectrally Constructed Background Illumination Rejection (opens in a new tab)

  5. Hardware for an electrical machines laboratory computer data acquisition system

    … system are studied and a system configuration proposed. Transducers for measuring voltage and current waveforms on a machine are considered and designed. The performance of the transducers constructed is evaluated in two sets of measurements. In the first set, measurement error, offset …

    ubc Repository record for Hardware for an electrical machines laboratory computer data acquisition system (opens in a new tab) Download PDF for Hardware for an electrical machines laboratory computer data acquisition system (opens in a new tab)

  6. Generalized impedance converter (GIC) filter utilizing composite amplifier

    … GIC filter chip fabrication. A composite operational amplifier utilizing the BiCMOS standard operational amplifier that was designed and introduced in a previous thesis is presented and its improved performance is investigated. The composite amplifier (C20A2) is designed using Silvaco EXPERT …

    nps Repository record for Generalized impedance converter (GIC) filter utilizing composite amplifier (opens in a new tab)

  7. Wideband active MMIC baluns -concepts and design

    … that can provide signal gain and a wide operational bandwidth. This work investigates three active balun designs operating between 2-18 GHz in 0.25 μm GaAs technology. The results are obtained from simulations in Keysight Advanced Design System using the UMS PH25-20 v.1.3.1 process design …

    chalmers Repository record for Wideband active MMIC baluns -concepts and design (opens in a new tab)

  8. A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition

    … generally weak and in the presence of stronger common mode signals. The INA thus needs to have very good Common Mode Rejection Ratio (CMRR) to amplify the weak biopotential while rejecting the stronger common mode interferers. Opamp based INAs with a resistor-capacitor feedback are suitable for …

    tamu Repository record for A High CMRR Instrumentation Amplifier for Biopotential Signal Acquisition (opens in a new tab)

  9. A Low Power Low Noise Instrumentation Amplifier For ECG Recording Applications

    … of the ECG system like the noise and common mode rejection ratio (CMRR). The extremely low ECG signal bandwidth also makes it difficult to achieve a fully integrated system. In this thesis, a fully integrated IA topology is presented that achieves low noise levels and low power …

    tamu Repository record for A Low Power Low Noise Instrumentation Amplifier For ECG Recording Applications (opens in a new tab)

  10. Resources for Integrated Quantum Sensing in the Mid-infrared

    … conversion efficiency of 57% at 2.07 μm, and a common-mode rejection ratio of 48 dB at 39.2 MHz.<br/><br/>We then utilise a silicon chip to implement an all-optical noise suppression<br/>scheme aimed at reducing the intensity noise of state-of-the-art pulsed lasers in this band via nonlinear …

    bristol Repository record for Resources for Integrated Quantum Sensing in the Mid-infrared (opens in a new tab) Download PDF for Resources for Integrated Quantum Sensing in the Mid-infrared (opens in a new tab)

  11. High common-mode-noise-rejecting magnetic gradiometer for biomagnetic measurements

    … focus on developing and characterising a high common-mode-noise-rejecting magneticgradiometer based on optically pumped magnetometers (OPMs). The work is motivated by the need to measure extremely weak magnetic signals, such as those produced by the heart and brain, which are often masked by …

    strathclyde Repository record for High common-mode-noise-rejecting magnetic gradiometer for biomagnetic measurements (opens in a new tab)

  12. Application of network transposition in the design of OTA-C filters and oscillators

    … signal processing have shown that the current-mode approach is superior to the voltage-mode in terms of its wide bandwidth, high speed, low voltage and power. As a wide range of voltage-mode analogue circuits already exist, a straightforward method of converting these voltage-mode circuits to …

    concordia Download PDF for Application of network transposition in the design of OTA-C filters and oscillators (opens in a new tab)

  13. Transimpedance amplifier design using 0.18 um CMOS technology

    … offers the potential for higher levels of integration since the analog circuits can be integrated with digital electronics on the same substrate. A 2.5 Gbps transimpedance amplifier fabricated using 0.18 um CMOS technology is presented. The TIA uses a shunt-shunt feedback topology with a cascode …

    queens Repository record for Transimpedance amplifier design using 0.18 um CMOS technology (opens in a new tab)

  14. An analog approach to interference suppression in ultra-wideband receivers

    … in the presense of such interference. The Operational Transconductance Amplifier (OTA) is the predominant building block in the design of the notch filter. In many cases, OTAs must handle input signals with large common mode swings. A new scheme for achieving rail-to-rail input to an OTA is …

    tamu Repository record for An analog approach to interference suppression in ultra-wideband receivers (opens in a new tab)

  15. High-Isolation Low-Power Active Quasi-Circulator for 44GHz Transceiver with Power and Noise Optimization in 0.18 Micrometer BICMOS

    … of antenna from transmitter to receiver. As modern trend of wireless communication, conventional ferrite circulator is huge, bulky and heavy to be integrated with analog and digital baseband processing circuits. Active circulators provide a compact high isolation solution for low power …

    tamu Repository record for High-Isolation Low-Power Active Quasi-Circulator for 44GHz Transceiver with Power and Noise Optimization in 0.18 Micrometer BICMOS (opens in a new tab)

  16. INVESTIGATION OF TECHNIQUES FOR REDUCING UNINTENTIONAL ELECTROMAGNETIC EMISSIONS FROM ELECTRONIC CIRCUITS AND SYSTEMS

    … the application of imbalance difference model to various circuit board and cable geometries, and balanced cable interface for reducing common-mode currents from power inverter. The first chapter discusses the importance and the meaning of the connection inductance associated with MLCCs …

    clemson Repository record for INVESTIGATION OF TECHNIQUES FOR REDUCING UNINTENTIONAL ELECTROMAGNETIC EMISSIONS FROM ELECTRONIC CIRCUITS AND SYSTEMS (opens in a new tab)

  17. Low-Noise Micro-Power Amplifiers for Biosignal Acquisition

    … wearable/implantable systems, the low-power operation of the biopotential amplifier is critical to avoid thermal damage to surrounding tissues, preserve long battery life, and enable wirelessly-delivered or harvested energy supply. For an ideal thermal-noise-limited amplifier, the amplifier …

    utk-theses Repository record for Low-Noise Micro-Power Amplifiers for Biosignal Acquisition (opens in a new tab)

  18. A 26 GHz Phase-Locked Loop Frequency Multiplier in 0.18-um CMOS

    … of 4 and a fully differential topology for rejection of common mode interference signals. The PLL is composed of a voltage controlled oscillator (VCO), injection-locked frequency divider (ILFD) for the first divide-by-two stage, a static master-slave flip-flop (MSFF) divider for the second …

    queens Repository record for A 26 GHz Phase-Locked Loop Frequency Multiplier in 0.18-um CMOS (opens in a new tab)

  19. Novel approaches in current-feedback operational amplifier design

    … bipolar junction transistor Current Feedback Operational Amplifier (CFOA) with a good Common-Mode Rejection Ratio (CMRR), suitable for radio frequency (RF) applications. This research focused on investigation of the established CFOA with the emphases of improving CMRR, bandwidth, Voltage-Offset …

    oxford-brookes Repository record for Novel approaches in current-feedback operational amplifier design (opens in a new tab) Download PDF for Novel approaches in current-feedback operational amplifier design (opens in a new tab)

  20. Novel fibre-optic-based interferometric sensors exploiting coherent and low-coherence signal processing techniques

    … source wavelength. The potential of using multi-mode laser diodes, as alternatives to the low coherence length sources such as LED' s or SLD ' s commonly used in 'white light' fibre-optic interferometric sensors has been studied. It is shown that the main advantage gained in using such sources is …

    kent Download PDF for Novel fibre-optic-based interferometric sensors exploiting coherent and low-coherence signal processing techniques (opens in a new tab)

Page 1 of 2