Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 363 for “"concrete frame"”.
-
Modelling the failure of reinforced concrete frame structures
Abstract not currently available.
-
Seismic Rehabilitation of Concrete Frame Beam-Column Joints
<p>Many reinforced concrete frame structures were designed and constructed before the development of seismic codes or according to earlier versions of seismic codes. Thus, these structures were designed only for gravity loads or for much lower lateral loads than the loads specified by the current …
-
Residual Capacity and Repairability of Reinforced Concrete Frame Buildings
Reinforced concrete (RC) frame buildings designed according to modern design standards achieved life-safety objectives during the Canterbury earthquakes in 2010-11 and the Kaikōura earthquake in 2016. These buildings formed ductile plastic hinges as intended and partial or total building collapse …
-
Behaviour of concrete frame structures under localised fire scenarios
… encompasses an investigation of the behaviour of concrete frame structure under localised fire scenarios by implementing a constitutive model using finite-element computer program. The investigation phase included properties of material at elevated temperature, description of computer program, …
-
Application of Base Isolation Systems to Reinforced Concrete Frame Buildings
… systems are widely used to protect reinforced concrete (RC) structures against the effects of strong ground motions. After a magnitude 6.6 earthquake, the outpatient building of Lushan People’s hospital in China remained in good condition due to the seismic isolation technology, while the …
-
Seismic Damage Assessment of Reinforced Concrete Frame Buildings in Canada
… on seismic design and assessment of reinforced concrete (RC) frame structure has shifted from force-based to performance-based design and assessment to accommodate strength and ductility for required performance of building. RC frame structure may suffer different levels of damage under …
-
A two-scale thermomechanical computational model for reinforced concrete frame structures
… is developed to study the behavior of reinforced concrete (RC) frame structures subject to fire loading. In this model, various structural components, such as beams, columns, and beam-column joints, are modeled by elastic elements connected by a set of nonlinear cohesive elements, which represent …
-
Seismic vulnerability of older reinforced concrete frame structures in Mid-America
… the seismic vulnerability of older reinforced concrete frame structures located in Mid-America. After designing a representative three-story gravity load designed reinforced concrete frame structure, a nonlinear analytical representation was used evaluate inter-story drift demands from …
-
Seismic Retrofit of Reinforced Concrete Frame Buildings with Tension Only Braces
Reinforced concrete buildings built prior to the enactment of modern seismic codes are often seismically deficient. These buildings may have inadequate strength and ductility to withstand strong earthquakes. Conventional retrofit techniques for such frame buildings involve adding reinforced …
-
Torsional response of reinforced concrete frame buildings subjected to blast loading
… involves a 10-storey symmetrical reinforced concrete frame structure designed in accordance with CSA Standard A23.3 (2004), and the provisions of the National Building Code of Canada (2005). The building was analyzed under different magnitudes of explosions, triggered at different distances …
-
Analysis of Reinforced Concrete Frame-Wall Structures for Strong Earthquake Motions
Made available in DSpace on 2014-12-13T19:31:51Z (GMT). No. of bitstreams: 1 7915342.pdf: 5744281 bytes, checksum: f604ab75b68cf7ffc8e38ef2abe71551 (MD5) Previous issue date: 1979
-
Fracture of high-strength bars in concrete frame members under earthquake loads
… failure mode in seismically detailed reinforced concrete frame members because it can lead to rapid strength loss and structural instability. The issue has recently attracted attention due to a national effort aimed at introducing high-strength reinforcing bars (HSRB) with yield strengths of 80 …
-
Kinematics-Based Modelling of Deep Transfer Girders in Reinforced Concrete Frame Structures
Reinforced concrete deep beams often carry heavy loads as transfer girders in high-rise buildings, pile caps in bridges or other important structural members. Due to their small slenderness, they exhibit shear failure with disturbed deformation patterns differently from slender beams. Many …
-
Explosive testing to assess dynamic load redistribution in a reinforced concrete frame building
… in a field test on a two-storey reinforced concrete frame specimen. The test consisted of removing a column with explosives and recording the deformations of the remaining columns in the structure. The explosives removed the load-carrying capacity of the column but also exerted an upward …
-
Effects of Strong-motion Duration on the Response of Reinforced Concrete Frame Buildings
… records on the seismic response of reinforced concrete frame buildings. For the purpose of the study, three reinforced concrete frame buildings (4-, 10-, and 16-storey) designed according to the 2005 edition of the National Building Code of Canada were considered in the analyses. The buildings …
-
Seismic Vulnerability Assessment of Reinforced Concrete Frame with Masonry Infill Buildings in New Zealand
A reinforced concrete frame with a masonry infill (RCFMI) construction system is one class of building type that is considered to be potentially earthquake-prone in New Zealand. This type of construction system comprises a significant proportion of commercial buildings constructed prior to the …
-
Seismic Vulnerability Assessment of Existing Reinforced Concrete Frame Structures: A Failure Mode-Based Approach
… in existing older-type and modern reinforced concrete (RC) frame structures. By mid-2017, the New Zealand parliament approved the Building Amendment Act 2016 which set new requirements for managing earthquake-prone structures. However, owing to a lack of sufficient knowledge on the seismic …
-
Performance-Based Economical Seismic Design of Multistory Reinforced Concrete Frame Buildings and Reliability Assessment
… optimal PBSD method for multi-story RC moment frames. This method is capable of overcoming the deficiencies of existing optimal PBSD methods and can be implemented by the U.S. design practice. The proposed method minimizes construction cost and takes the limit of member plastic rotation and …
Page 1 of 19