Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 16 of 16 for “"condensate water"”

  1. Direct mixing of geothermal water and condensate into heated groundwater at Nesjavellir power station

    … which plays a vital role in supplying hot water for space heating in the capital area. The power station operates as a co-generative single-flash geothermal plant, generating electricity using high-temperature geothermal steam and utilizing geothermal water to heat groundwater for hot water …

    reykjavik Repository record for Direct mixing of geothermal water and condensate into heated groundwater at Nesjavellir power station (opens in a new tab)

  2. Comparative Analysis of Heat Exchangers and Continued Investigation of Variable Speed Versus Constant Speed Pump Systems in KU's Steam Power Plant

    … to compare the power consumption of two specific condensate pumps, also in the steam power plant located at the University of Kansas. The power plant generates and supplies steam (not electricity) to the buildings on the KU campus. The boilers in the plant require fuel (natural gas) to convert the …

    ku Repository record for Comparative Analysis of Heat Exchangers and Continued Investigation of Variable Speed Versus Constant Speed Pump Systems in KU's Steam Power Plant (opens in a new tab)

  3. Evaluation of Grundfos CRE 15-3 Variable Speed Centrifugal Pump and Worthington Constant Speed Centrifugal Pump Applications in KU Steam Power Plant

    … These two types of pumps are used to supply condensate water to two different components of the steam power plant. One component is the deaerator tank, whose function is to preheat and deaerate the condensate water, before it is supplied to the boiler. This deareator tank is located in the …

    ku Repository record for Evaluation of Grundfos CRE 15-3 Variable Speed Centrifugal Pump and Worthington Constant Speed Centrifugal Pump Applications in KU Steam Power Plant (opens in a new tab)

  4. Waste stream reclamation for food manufacturing operations using membrane filtration

    … operations include significant amounts of water. In many applications, water is used dilute organic or inorganic materials for transportation to a waste treatment facility. The composition and concentration of the waste streams are variable and depend on the type of manufacturing and on the …

    ohiolink Repository record for Waste stream reclamation for food manufacturing operations using membrane filtration (opens in a new tab)

  5. Balancescapes: an investigation into the effectiveness of site-scale water harvesting in St. Louis, Missouri

    … irrigation is a prodigious consumer of potable water and accounts for more than 50% of urban water use in the United States. It is therefore imperative to reserve potable water for essential uses. The variability of recent drought trends coupled with the prediction of more intense, less frequent …

    ksu Repository record for Balancescapes: an investigation into the effectiveness of site-scale water harvesting in St. Louis, Missouri (opens in a new tab)

  6. Improving Vapor Compression Cycle Efficiencies in Support of Conventional Refrigerant Phaseouts

    … at the condenser air inlet with external supply water sources being either producing COP highest improvements of 60% and internal water supplied by the evaporator condensate producing COP highest improvements 38%. The second set of modifications investigated are based on installing at the …

    tamu Repository record for Improving Vapor Compression Cycle Efficiencies in Support of Conventional Refrigerant Phaseouts (opens in a new tab)

  7. Gas hydrate kinetics, transportability, interfacial phenomena and novel measurements applied to develop a new transient partially dispersed and segregated multiphase flow model for field applications

    … are no longer flowing. The presence of a free water phase, being correlated with increased risk of gas hydrate plugging, also corresponds to being the least well understood gas hydrate/multiphase flow scenario, especially when transient flow phenomena are prevalent, and the flowline geometry …

    colo-mines Repository record for Gas hydrate kinetics, transportability, interfacial phenomena and novel measurements applied to develop a new transient partially dispersed and segregated multiphase flow model for field applications (opens in a new tab)

  8. Development of a successful chemical treatment of gas wells with condensate or water blocking damage

    During production from gas condensate reservoirs, significant productivity loss occurs after the pressure near the production wells drops below the dew point of the hydrocarbon fluid. Several methods such as gas recycling, hydraulic fracturing and solvent injection have been tried to restore gas …

    texas Repository record for Development of a successful chemical treatment of gas wells with condensate or water blocking damage (opens in a new tab)

  9. Laminar-flow Liquid-to-air Heat Exchangers - Energy-efficient Display Cabinet Applications

    … velocities in combination with condensation of water vapour, and sometimes even frosting, and is therefore different from other applications where flat-tube heat exchangers have been used earlier. The objective of this research work has been to find a suitable, more energy-efficient, heat …

    lund Repository record for Laminar-flow Liquid-to-air Heat Exchangers - Energy-efficient Display Cabinet Applications (opens in a new tab)

  10. Investigation of hydrate formation and transportability in mutiphase flow systems

    … experiments were carried out at varying water cut (WC) from 15 to 100 vol.%, liquid loading (LL) from 50 to 85 vol.%, mixture velocity (vmix) from 0.75 to 3 m/s, for three fluids systems (100 % WC, water in Conroe crude oil emulsions and King Ranch condensate + water) on the ExxonMobil …

    colo-mines Repository record for Investigation of hydrate formation and transportability in mutiphase flow systems (opens in a new tab)

  11. The Effects of Oscillatory Steam Flow on Reflux Condensation Phenomena

    … condenser, were: (1) reflux condensation without water column mode, (2) reflux condensation with water column mode, (3) first carry-over mode, (4) second carry over mode, (5) climbing film flow mode. Complete reflux condensation was maintained only in the first two modes of operation.</p> <p>Under …

    mcmaster Repository record for The Effects of Oscillatory Steam Flow on Reflux Condensation Phenomena (opens in a new tab)

  12. Náhrada základních výměníků v Teplárně Malešice

    Hlavním úkolem této diplomové práce je navržení dvoucestného výměníku tepla s integrovaným chladičem parovzdušní směsi a porovnání materiálů teplosměnné plochy. Dalším úkolem je pevnostní dimenzování tohoto výměníku a ekonomická efektivnost použitých materiálů teplosměnných ploch.

    brno-tech Repository record for Náhrada základních výměníků v Teplárně Malešice (opens in a new tab)

  13. Techno-economic evaluation of integrated process flowsheets for vinasse management with value addition for decision making

    … into the atmosphere. Additionally, disposal into water bodies results in eutrophication due to the overload of plant nutrients (N, P and K). Further, owing to the high potassium content, the use of dewatered vinasse as animal feed supplements has been shown to cause digestive tract problems in …

    cape-town Repository record for Techno-economic evaluation of integrated process flowsheets for vinasse management with value addition for decision making (opens in a new tab)

  14. The Impacts of Hydrocarbon Statutory Regulation on Liquid-Loading Wells

    … test may impose a less than optimum rate for condensate gas production. This study investigates ways to improve the generalized 3-step multi-rate test limitation currently required in some regulatory environments. The work starts with gathering gas condensate field data, including historical …

    houston Repository record for The Impacts of Hydrocarbon Statutory Regulation on Liquid-Loading Wells (opens in a new tab)

  15. Evaluation of two water reuse applications : cooling tower makeup water and residential HVAC condensate reuse

    This study evaluated the potential impacts of two water reuse applications – urban cooling towers and residential homes. Large water demands make cooling towers an attractive target for water reuse applications. However, poorly operated cooling towers have historically been linked to diseases such …

    texas Repository record for Evaluation of two water reuse applications : cooling tower makeup water and residential HVAC condensate reuse (opens in a new tab)