Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 149 for “"cone-beam CT"”.
-
Cone beam CT in orthodontics
Radboud Universiteit Nijmegen, 11 januari 2013
-
Region-of-Interest Reconstruction from Truncated Cone-Beam CT
… a novel algorithm in 3D computed tomography (CT) dedicated to accurate region of interest (ROI) reconstruction from truncated cone-beam projections. Here data acquisition involves cone-beam x-ray sources positioned on any piecewise smooth 3D-curve satisfying the very generic, classical Tuy's …
-
Improving cone-beam CT image quality using non-circular orbits
Cone-beam CT (CBCT) is widely used for intraoperative image guidance, but its image quality is limited by the conditions of conventional single-energy circular-orbit acquisition. A single circular orbit fails Tuy's sampling-completeness condition off the central plane, leaving a missing region of …
-
Motion binning in cone-beam CT without a prior Model
Cone-beam CT (CBCT), used to reduce setup error in radiotherapy, takes a sequence of about 670 two-dimensional X-rays acquired in a circular arc around the patient over two minutes and reconstructs a three-dimensional volume from these projections. Consequently, when tissues move significantly …
-
Deformable Image Registration for Surgical Guidance using Intraoperative Cone-Beam CT
… normal anatomy is essential to safe and effective surgery. Preoperative computed tomography (CT) and/or magnetic resonance (MR) images offer exquisite visualization of anatomy and a valuable basis for surgical planning. Multimodality deformable image registration (DIR) can be used to bring …
-
Implementation of respiratory-correlated cone-beam CT on Varian linac systems
Respiratory-correlated (4D) X-ray CT scans produce a set of images corresponding to different phases of a patient's breathing cycle. In external beam radiotherapy, information about a tumor's motion due to respiration can be used to optimize a treatment plan, provided the patient can be accurately …
-
Segmentation automatique des dents en imagerie maxillo-faciale Cone Beam CT
… La représentation tridimensionnelle de ces structures, et plus particulièrement des dents, fournit une compréhension poussée des relations dento-maxillo-faciales, ce qui permet au clinicien de sélectionner un plan de traitement optimisé. L’obtention de ces modèles personnalisés se faisant à …
-
Detection of Simulated Apical Root Resorption Using Three Cone Beam CT Machines
… simulated apical root resorption (SARR) on extracted teeth, using the output from three cone beam computed tomography (CBCT) machines. Twenty-four unrestored maxillary anterior teeth exhibiting normal morphology, were collected. The teeth were scanned by three CBCT machines: 1) the NewTom 3G (AFP …
-
Factors Influencing Contrast Resolution of Cone Beam CT Using the CB MercuRay
Introduction: Cone Beam Computed Tomography (CBCT) has an application in all dental specialties. CBCT is an aid in implant dentistry to evaluate anatomical landmarks in both quality and quantity. Hounsfield Unit (HU) values represent a grayscale that is standardized on CT machines relative to the …
-
Cone Beam CT and Digital Radiography. A Comparative Study of P/A Cephalometrics.
… cephalogram measurements could be obtained from Cone Beam Computerized Tomographic (CBCT) images taken on the NewTom QR-DVT 9000™. Fifteen frontal cephalometric radiographs were chosen for good image quality, with no regard for patient age or gender. Each cephalogram was traced three times by the …
-
Improvement of image reconstruction speed with GPU in cone beam CT breast imaging
… women in the United States. Our group is constructing a dedicated cone beam breast CT (CBCT) system to provide true 3D image to improve the screening and diagnostic of breast cancer. Our result shows that dedicated CBCT out-perform a lot than conventional CT when detecting micro-calcification …
-
Comparative linear accuracy of cone beam CT derived 3D images in orthodontic analysis.
Objective . To compare the in vitro reliability and accuracy of linear measurements between cephalometric landmarks on CBCT 3D images with varying basis projection images to direct measurements on human skulls. Methods . Sixteen linear dimensions between anatomical sites marked on 19 human skulls …
-
Novel methods for scatter correction and dual energy imaging in cone-beam CT
… scatter contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. This study investigates a method that combines measurement-based scatter correction and a compressed sensing (CS)-based iterative reconstruction algorithm to generate scatter-free images from low-dose data. Scatter …
-
Towards Translation of Dedicated Breast Cone-Beam CT for the Detection of Microcalcifications
… chance based on genetic and familial risk factors. There is a clear and present need to reduce the burden of breast cancer through screening and diagnosis for early detection of the disease and to potentially begin treatment earlier. Breast cancer screening using mammography has demonstrated …
-
Image Quality, Modeling, and Design for High-Performance Cone-Beam CT of the Head
… on visualization of fine, subtle anatomical structures in the head. In particular, high-quality head imaging at the point of care mitigates patient risk associated with transport and decreases time to diagnosis for time-sensitive diseases. Cone-beam computed tomography (CBCT) systems have found …
-
A dosimetric study of kilovoltage cone beam CT image guidance in gynaecological radiation therapy
Cone beam CT (CBCT) is increasingly used in image guided radiation therapy in order to ensure more accurate patient setup and target localization. However, the issue of patient dose due to repeated imaging procedures is an important topic in radiation medicine today. This thesis rigorously explores …
-
Generative AI for cone-beam CT dose reduction and intensity correction in adaptive radiotherapy
In image-guided radiotherapy (IGRT), cone-beam computed tomography (CBCT) is used to align patients in the treatment position. CBCT scans administer radiation exposure and subject patients to secondary cancer risk. However, lowering CBCT imaging dose continues to be challenging as the image quality …
-
Entwicklung eines neuen vorwissensbasierten Bildrekonstruktionsalgorithmus für die Cone-Beam-CT Bildgebung in der Strahlentherapie
… durchgeführt werden. Die sogenannte Kegel-Strahl-CT (Cone-Beam-CT, CBCT) erlaubt eine präzise Verifikation der Patientenlagerung sowie ein Ausgleich von Lagerungsungenauigkeiten. Dem Nutzen der verbesserten Patientenlagerung steht jedoch bei täglicher Anwendung eine erhöhte, nicht zu …
Page 1 of 8