Showing 1 to 20 of 483 for “"cone-beam computed tomography"”.
-
Cone-Beam Computed Tomography For Neuro-Angiographic Imaging
… small footprint, and adaptable geometry, cone-beam computed tomography (CBCT) systems have shown to be valuable for point of care applications that require timely diagnosis. However, image quality in CBCT scanners are potentially limited by slow rotation speed and are therefore challenged …
-
Cone-Beam Computed Tomography and Orthodontics: Awareness Assessment
… community's knowledge and understanding of Cone-Beam Computed Tomography (CBCT) technology as well as awareness of the implications of CBCT use, including risk assessment, radiation dose estimation, diagnostic utility, and issues of informed consent. It is incumbent on the profession to …
-
Efficacy of cone beam computed tomography use in endodontics
IINTRODUCTION: This study’s aims were to: 1) evaluate whether or not there was a treat- ment plan change, if CBCT is used; and 2) evaluate if the use of CBCT as diagnostic tool improves the treatment outcome. We hypothesized that 1. the use of CBCT as diagnostic tool changes the treatment plan; and …
-
Deep Autofocus for Motion Compensation in Cone-Beam Computed Tomography
Cone-beam computed tomography (CBCT) is increasingly used in interventional radiology, providing 3D imaging for procedure planning, guidance, and outcome assessment. In neuroradiology, CBCT is a critical tool for various applications, including brain perfusion, radiotherapy, and stroke diagnosis. …
-
Applications of cone beam computed tomography in radiotherapy treatment planning.
… capable of 2D planar imaging, fluoroscopy and 3D Cone Beam Computed Tomography (CBCT) imaging. With CBCT imaging, the treatment plan can be modified based on patient’s anatomy just before the treatment session. This method of Adaptive Radiotherapy (ART) helps in managing a patient’s treatment by …
-
Investigation of Imaging Capabilities for Dual Cone-Beam Computed Tomography
<p>A bench-top dual cone-beam computed tomography (CBCT) system was developed consisting of two orthogonally placed 40x30 cm<super>2</super> flat-panel detectors and two conventional X-ray tubes with two individual high-voltage generators sharing the same rotational axis. The X-ray source to …
-
The Clinical Applications of Cone Beam Computed Tomography in Endodontics
… of 5 investigations assessed the application of cone beam computed tomography (CBCT) for the management of endodontic problems. Cone beam computed tomography improved the detection of the presence and absence of simulated periapical lesions in human dry mandibles. The overall sensitivity was …
-
Algorithms for Quantitative Imaging with Advanced Cone-Beam Computed Tomography Configurations
Cone-Beam Computed Tomography (CBCT) is an emerging technology that offers several potential advantages over conventional multi-detector CT, including superior spatial resolution, point-of-care accessibility, and flexible mechanical designs enabling application-specific scanner configurations. When …
-
Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy
Kilovoltage cone-beam computed tomography (kV CBCT) has important applications in image guided radiation therapy (IGRT). In its current state, CBCT is suboptimal for these applications due to its considerable radiation dose, poor soft-tissue contrast and inaccurate Hounsfield Units as a result of …
-
A Digitized Comparison using Cone Beam Computed Tomography and Intraoral Scanning
… a missing tooth in area #19 were examined. Cone beam computed tomography .STL files were used as the first test group. Intraoral scans were used as the second test group. Desktop scans of each model and the .STL file was used as a control. The .STL files were then superimposed onto each …
-
CONE BEAM COMPUTED TOMOGRAPHY (CBCT) DOSIMETRY: MEASUREMENTS AND MONTE CARLO SIMULATIONS
<p>Cone beam computed tomography (CBCT) is a 3D x-ray imaging technique in which the x-ray beam is transmitted to an object with wide beam geometry producing a 2D image per projection. Due to its faster image acquisition time, wide coverage length per scan, and fewer motion artifacts, the CBCT …
-
CONE-BEAM COMPUTED TOMOGRAPHY (CBCT) SEGMENTATION BY ADVERSARIAL LEARNING DOMAIN ADAPTATION
Cone-beam computed tomography (CBCT) is increasingly used in radiotherapy for patient alignment and adaptive therapy where organ segmentation and target delineation are often required. However, due to the poor image quality, low soft tissue contrast, as well as the difficulty in acquiring …
-
X-ray scattering point models for breast cone-beam computed tomography
… scattering point models in full-field breast Cone-Beam Computed Tomography (CBCT). A many Scattering Point (MSP) per incident beamlet model and a Single Scat- tering Point (SSP) model were tested against Geant4 simulations, as well as against each other. Comparisons were made using both …
-
Patient studies on shading correction for cone-beam computed tomography images
… thesis explores the efficacy of using planning Computed Tomography (CT) images as prior knowledge to improve quantitative cone-beam CT (CBCT) image quality in radiation therapy. CBCT is a significant component in the treatment planning process of image-guided radiation therapy (IGRT). Current …
-
Optimization of Non-Local Means filtration for Cone Beam Computed Tomography
Cone Beam Computed Tomography (CBCT) is a medical imaging technique used to visualize the internals of an object from a set of X-ray images. The X-ray images are taken with a cone shaped X-ray beam at many angles around the object being visualized. The images are then back projected through a …
-
Root Resorption Detection by Multiple Radiographs versus Cone-Beam Computed Tomography
… traditional two-dimensional radiographs and cone-beam computed tomography (CBCT). Methods: A convenience sample was utilized to identify pediatric patients with impacted teeth who have both CBCT imaging and multiple traditional radiographs (N = 34). Graduate dental residents specializing in …
-
IMPROVED IMAGE QUALITY IN CONE-BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED INTERVENTIONS
In the past few decades, cone-beam computed tomography (CBCT) emerged as a rapidly developing imaging modality that provides single rotation 3D volumetric reconstruction with sub-millimeter spatial resolution. Compared to the conventional multi-detector CT (MDCT), CBCT exhibited a number of …