  1. Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads

    … control for boost converters supplying constant impedance and constant power loads. The first part of this thesis reviews the conventional sliding-mode controller for boost converters with simple resistive load and identifies its drawback, whereupon an observer-based fixed-frequency …

    ubc Repository record for Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads (opens in a new tab) Download PDF for Sliding-mode control of DC–DC boost converter with constant impedance and constant power loads (opens in a new tab)

  2. A HIGHLY EFFICIENT, MEGAWATT CLASS CONSTANT IMPEDANCE TUNABLE POWER EXTRACTION CIRCUIT FOR MOBILE IONOSPHERIC HEATERS

    … matching the relatively high electron beam impedance (5 kΩ) to the load antenna (50 Ω) creates situations where high Q resonant circuits are necessary to achieve the high efficiencies required. We design a pi-circuit to achieve the impedance matching and validate the design experimentally. …

    maryland Repository record for A HIGHLY EFFICIENT, MEGAWATT CLASS CONSTANT IMPEDANCE TUNABLE POWER EXTRACTION CIRCUIT FOR MOBILE IONOSPHERIC HEATERS (opens in a new tab)

  3. Sparse Formulation of Lyapunov Direct Method Applied to Transient Power System Stability

    … networks. Also, all system loads are modeled as constant impedance loads in order to use conventional techniques to reduce the network to the internal nodes of the generators. Many loads in practical power systems can be represented as constant power loads. Such loads are conventionally …

    mcmaster Repository record for Sparse Formulation of Lyapunov Direct Method Applied to Transient Power System Stability (opens in a new tab)

  4. Dynamic load modeling in power system analysis

    … to compare the results with those obtained using constant impedance or constant current load models. A least-squares curve fit algorithm is developed and used in modeling static and quasi-static loads as a function of the bus voltage. A dynamic model for the induction machine which accounts for …

    vt Repository record for Dynamic load modeling in power system analysis (opens in a new tab)

  5. Equivalent impedance of rough surface at low grazing angles

    Equivalent impedance of a rough surface is determined by solving the problem of radiowave propagation over rough random surface by using the parabolic equation method. We consider horizontal polarization and assume the rough surface, defined by discrete points, to be perfectly conducting. This …

    nps Repository record for Equivalent impedance of rough surface at low grazing angles (opens in a new tab)

  6. Investigation of islanding operation in a small distribution network with small scale generation unit

    … and the customers are represented with lumped constant impedance loads. However, the other components of the system, such as transformers, cables, OHLs and generators are modelled in detail. Different islanding scenarios are simulated based on possible faults in the system. The results are …

    chalmers Repository record for Investigation of islanding operation in a small distribution network with small scale generation unit (opens in a new tab)

  7. Versatile Three-Phase Power Electronics Converter based Real-time Load Emulators

    … loading conditions.</p> <p>In the application, constant impedance, constant current and constant power (ZIP) load has been emulated to represent power system steady state load, with reference to voltage and frequency variations. Also, an induction motor represented dynamic load emulator is …

    utk-theses Repository record for Versatile Three-Phase Power Electronics Converter based Real-time Load Emulators (opens in a new tab)

  8. Sub-nanosecond breakdown in argon and air

    … in order to minimize rise time and reduce impedance mismatches. All experiments performed in this research used a pulse delivery system with short coaxial transmission lines feeding an axial or radial spark gap inside a vacuum chamber. The gap geometry, whether it was axial or radial, …

    ttu Repository record for Sub-nanosecond breakdown in argon and air (opens in a new tab)

  9. Ultrafast Laser Sampling of a Plant Tissue and ion Conductivity Measurement for Investigation of Light Stress Generation Mechanisms

    … measurement in nanoliter volume. We measured the impedance which is reciprocal of conductivity using a lock-in amplifier and a precise current source at frequency of 130 Hz. Initially high impedance of mutant sample tended to drop within 2 hours and finally approached the constant value which …

    unt Repository record for Ultrafast Laser Sampling of a Plant Tissue and ion Conductivity Measurement for Investigation of Light Stress Generation Mechanisms (opens in a new tab)

  10. Propagation Effect In Inhomogeneous Media, Including Media With Light-induced And Fixed Gratings

    … various types of volume gratings, materials with constant impendence and optical fibers are studied. Instability of cross–phase modulation and of Energy transfer via GRON-type (Grating-type Orientational Nonlinearity in Liquid Crystal) Stimulated Scattering is numerically observed. Two diffractive …

    ucf Repository record for Propagation Effect In Inhomogeneous Media, Including Media With Light-induced And Fixed Gratings (opens in a new tab)

  11. Transient stability of power systems with non-linear load models using individual machine energy functions

    … are represented by any desired combination of constant impedance, constant current or constant-MVA models. The effect of the non-linear loads is reflected at the internal nodes of the generators as injected currents. The non-linear injected currents account for the sudden voltage changes …

    iastate Repository record for Transient stability of power systems with non-linear load models using individual machine energy functions (opens in a new tab)

  12. Incentive Design of Conservation Voltage Reduction Planning for Industrial Loads in Ontario

    … facilities are represented by a combination of constant impedance, constant current, and constant power loads. A detailed case study for Ontario, Canada, is carried out considering that industrial loads are investing in CVR implementation to reduce their energy costs. The optimal incentives that …

    waterloo Repository record for Incentive Design of Conservation Voltage Reduction Planning for Industrial Loads in Ontario (opens in a new tab)

  13. MODELING AND CONTROL OF MICROGRID COMPONENTS

    … that includes an example system consisting of a constant impedance load, a $\pi-$modeled line and an inverter-based generator. We also develop a generic port-Hamiltonian model for loads that allows through the appropriate selection of structure and controls the mimicking of the behavior of …

    oklahoma-thes Repository record for MODELING AND CONTROL OF MICROGRID COMPONENTS (opens in a new tab) Restricted access

  14. Equivalent load model of induction machines connected to a common bus

    … active and reactive power compared with purely constant impedance and constant current load representations.</p>

    iastate Repository record for Equivalent load model of induction machines connected to a common bus (opens in a new tab)

  15. Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation

    … signal models of the two-generation system with constant current and constant impedance load are developed, and the main reasons that cause instability are researched and verified. The developed SG emulator is also verified in the two-area system by comparing the system dynamics visually.</p> …

    utk-theses Repository record for Three-Phase Power Converter Based Real-Time Synchronous Generator Emulation (opens in a new tab)

  16. An Efficient Approach For Dynamic Stability Analysis of Power Systems - Including Load Effects

    … the use of a power system stabilizer with a constant power local load leads to a prediction of instability while stability is predicted for a constant impedance load model.</p>

    mcmaster Repository record for An Efficient Approach For Dynamic Stability Analysis of Power Systems - Including Load Effects (opens in a new tab)

  17. Supervisory Hybrid Control of a Wind Energy Conversion and Battery Storage System

    … converter unit. A bank of static (constant impedance) and dynamic (induction motor) loads is connected to the point of common coupling through a step down transformer. A finite hybrid-automata based model of the wind energy conversion and storage system has been proposed that …

    toronto-retro Repository record for Supervisory Hybrid Control of a Wind Energy Conversion and Battery Storage System (opens in a new tab)

  18. Analysis of STATCOM for voltage dip mitigation

    … dip magnitude. This is done for different grid impedances and load characteristics (i.e. constant impedance load and constant current load). The results of this study show that the shunt compensation current, injected active and reactive power decrease as the impedance, which is the source …

    chalmers Repository record for Analysis of STATCOM for voltage dip mitigation (opens in a new tab)

  19. Developing Ringdown Oscillation Monitoring Techniques using Synchrophasor Data with Applications to New Zealand Network

    … worst damping performance was identified under constant power load while the best damping performance occurred under the constant impedance.

    auckland-ms Repository record for Developing Ringdown Oscillation Monitoring Techniques using Synchrophasor Data with Applications to New Zealand Network (opens in a new tab)

  20. Impacts of Large-Scale Integration of Solar Photovoltaics and Load Characteristics on Power System Voltage Stability

    … motor loads are introduced beside complex (constant impedance and constant current) loads is significantly higher than that of the case when having complex loads only. Moreover, the system is more likely to have a voltage collapse with less number of cascaded disturbances in the case when …

    chalmers Repository record for Impacts of Large-Scale Integration of Solar Photovoltaics and Load Characteristics on Power System Voltage Stability (opens in a new tab)