Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"constant phase element"”.
-
Emulování fraktálních prvků pomocí pasivních laditelných součástek
… věnována ladění celkové kapacity struktur typu Constant phase element (CPE), změnou stejnosměrného napětí. Výstupem práce je návrh několika CPE, které budou se budou odvíjet od teoretického předpokladu a zároveň budou vhodné pro kontrolovanou změnu pseudokapacity. Změna pseudokapacity bude dále …
-
Microfluidic platform for impedance characterization of endothelial cells under fluid shear stress.
… resistance, cell membrane capacitance, constant phase element, and the resistance of cell culture medium. Results confirmed that while the trans-endothelial resistance and cell membrane capacitance were suitable measurements for cell permeability and confluency respectively, the constant …
-
The stability of anodic oxide films on gold and the difference between their interfacial capacitance and that at the Au-metal surface
… Impedance Spectroscopy, Cdl is derived from constant-phase element (CPE) values and the CPE parameter, ϕ, which is found to be near unity for most conditions. In the second part of this thesis, the stability of the compact, so-called alpha-oxide film on gold electrodes in contact with …
-
Fractional modelling of rechargeable batteries
… one or two RC networks and sometimes a Warburg element. These models are usually based on frequency range that stretches to only 1 mHz. This explains why they require several parameters to accurately reproduce the measured impedance data. In most applications, a battery goes through a …
-
Vybrané praktické aplikace fraktálních dvojpólů v imitančních a přenosových funkcích
… struktuře prvku s konstantní fázovou odezvou (constant phase element, dále jen CPE) založeného na sério-paralelním zapojení rezistorů a kondenzátorů. Následují rozbory vybraných zapojení pro implementaci takto navrženého CPE prvku a jejich možné srovnání s jinými zapojeními podobného typu v …
-
Fabrication and modeling of electrochemical double-layer capacitors using carbon nano-onion electrode structures
… resistor, an inductor, a capacitor (RLC), and a constant phase element (CPE), was developed along with a parameter extraction procedure for the benefit of other users. The new model developed, proved to be more accurate than previously reported UC models.
-
Fabrication and modelling of an all-printed PEDOT:PSS supercapacitor on a commercial paper
… modelling is utilized. Instead of using a constant phase element (CPE), a multiple time constant model is proposed in order to explain the physical origin of the distributed time constant behaviour. Thickness variation of the PEDOT:PSS electrode is assumed as a primary reason for the …
-
Software Development for Neuroscience, Biology, and Biomechanics Applications
… the software measures the magnitude and phase of the interface, and fits the most commonly used Randles model. The software was evaluated using five custom-made nerve cuffs. The Randles model parameters, including the constant phase element, were calculated and are in good agreement with …
-
CellMap: An Automated Multielectrode Array Cell Culture Analysis System Based on Electrochemical Impedance Spectroscopy
… observations. Similarly, the cell layer Constant Phase Element (CPE) parameters, which were found to correlate well with cell density distribution, also increased as a function of time until confluence and decreased thereafter. Additionally, the cell-growth mapping revealed that the …
-
Novel planar interdigital sensors for the detection of bacterial endotoxins : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philososphy in Electronics Engineering at Massey University, Palmerston North, New Zealand
… The impedance spectra were modelled using a Constant Phase-Element (CPE) equivalent circuit, and a Principal Component Analysis (PCA) was used for data classification. Sensors coated with APTES have shown better selectivity towards LPS detection. The experiments were repeated by coating APTES …
-
Thin film calixresorcinarene membranes for chemical sensing.
… gold electrodes by the C[4]RA film changes their constant phase element impedance, givenby 1/(w.Q)" with w being the angular velocity. The observed values were from Q =0.725-10 -5 Farad and n = 0.87 to Q = 0.828-10-6 Farad and n = 0.82. Organic analyteslike, chloroform and acetone in water can be …
-
Silicon Nanocrystal Based Light Emitting Devices for Silicon Photonics
… is proposed and an electrical model based on the constant phase element (CPE) is derived. It is, then, given a physical interpretation of the electrical model proposed by considering the disordered composition of the active material. The electrical model is further generalized for many kinds of …
-
Study on Electrolyte-gated Graphene Nanoelectronic Biosensors for Biomarker Detection
… interface exhibits a complex constant phase element (CPE) behavior (1 �� = ��0 (����) �� ) with both ��0 and �� varying as functions of the gate voltage. The EDL capacitance and the quantum capacitance are determined which allows us to extract the carrier density and mobility …
-
Inflammation and Corrosion in Total Hip Prostheses: The Generation and Interaction of Reactive Oxygen Species with CoCrMo Metallic Biomaterial Surfaces
… corrosion resistance (RP) with increased constant phase element capacitance (CPE Q) and open circuit potentials (OCPs), indicating that ROS are major contributors in corrosion susceptibility. By interpreting these observations and results, we were able to demonstrate that ROS are …
-
Cathodic processes at electrodes in potassium fluoride-hydrofluoric acid (1/2) and potassium hydroxide-water (1/2) melts and the effect of adsorbed catalyst poisons.
… measurements at the solid/melt/H$\sb2$ gas interphase and experimental in situ determinations of double-layer capacitance, C$\rm\sb{dl},$ were carried out, and the effect of wettability and accessibility of electrolytes to the inner pores of the porous surface in association with the surface …
-
Dynamická elektroneurostimulace a elektrické vlastnosti kůže
Tato diplomová práce se zabývá teoretickým základem dynamické elektroneurostimulace, co je působení elektrického signálu na akupunkturní body na kůi. Touto technikou jsou vybaveny přístroje firmy DiaDENS ruské provenience. Praktická část je věnována návrhu modelu impedance lidské kůe, zejména pak …
-
Synthesis and Electrical Characterization of Calcia-stabilised Zirconia and Mg-doped Alumina
… process, the relative importance of individual elements to the overall impedance response was highlighted by a new approach by the deconvolution of the impedance spectra. The bulk, grain boundary and electrode contact impedances of CSZ ceramics were characterised over the temperature range …
-
Μορφοποίηση ηλεκτροδίων άνθρακα και εφαρμογή τους σε αναλυτικούς και βιοαναλυτικούς σκοπούς
… capacitive behavior is descriped by a constant phase element (CPE), (originating from inhomogeneity and/or the roughness of the modified electrode surface). The Quality Fitting Diagrams exhibited the absolutely satisfactory representation of the frequency response by the selected …
-
Energy analysis and fabrication of photovoltaic thermal water electrolyzer and ion transport through modified nanoporous membranes
… in electrolytes without a redox couple. Using a constant phase element (CPE) series resistance model, prolonged incubation times (up to 120 h) show decreasing monolayer capacitance approaching the theoretical value for 1-undecanethiol (Chapter 6). Secondly, we fabricated a membrane permeate flow …
-
GROWTH, FABRICATION AND CHARACTERIZATION OF Cu<sub>2</sub>ZnSn(S<sub>x</sub>Se<sub>1-x</sub>)<sub>4</sub> PHOTOVOLTAIC ABSORBER AND THIN-FILM HETEROJUNCTION SOLAR CELLS
… photo-absorber materials use rare and expensive elements, such as In, Te, Ga, and toxic Cd which severely limit the mass production and deployment of these solar cells. Thus, a major research effort is focused toward the development of new photovoltaic (PV) absorber materials comprising of …
Page 1 of 2