Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 44 for “"constantan"”.

  1. Ageing effects on iron-constantan thermocouples

    vt Repository record for Ageing effects on iron-constantan thermocouples (opens in a new tab)

  2. A Resistance Based Structural Health Monitoring System for Composite Structure Applications

    … properties of fiber such as carbon, copper, or constantan - a copper-nickel alloy - can be utilized as sensors within the structure. This allows the structure to provide feedback via electrical signals to a user which are essential for evaluating the health of the structure. In this research, …

    calpoly Repository record for A Resistance Based Structural Health Monitoring System for Composite Structure Applications (opens in a new tab)

  3. Application of inkjet printing technology to flexible batteries

    … by particle free silver ink by inkjet printing. Constantan particle suspension ink is invented to make constantan sensors and resistors. A new chemical reducing sintering (CRS) is used to eliminate oxidation layers and sinter the constantan at low temperature. CRS is much safer and easier than …

    njit Repository record for Application of inkjet printing technology to flexible batteries (opens in a new tab)

  4. Heat transfer coefficients between condensing organic vapors and a vertical copper tube

    … On the surface of this tube were imbedded six constantan wires at equal intervals to form copper-constantan couples for measuring the tube wall temperatures. Other temperatures throughout the system were measured by a series of electrical resistance thermometers so that a complete heat balance …

    vt Repository record for Heat transfer coefficients between condensing organic vapors and a vertical copper tube (opens in a new tab)

  5. Microcalorimetric investigations: Part I. Construction of a microcalorimeter for heats of combustion. Part II. Heats and entropies of ionization of some anilines.

    … of a differentially-connected system of two iron-constantan thermopiles, each being constructed of sixteen thermocouples. The recording of the heat liberated is accomplished by means of a d.c. amplifier; the areas thus recorded are integrated by an electronic integrator. The apparatus is capable …

    ottawa-retro Repository record for Microcalorimetric investigations: Part I. Construction of a microcalorimeter for heats of combustion. Part II. Heats and entropies of ionization of some anilines. (opens in a new tab)

  6. Deposition temperature of evaporated permalloy films

    A vacuum evaporated chromel and constantan thin film thermocouple is developed and used to measure the deposition temperature of evaporated permalloy films. The maximum permalloy film temperature is 12000 higher than the glass substrate temperature during deposition for low evaporation rate, 15 …

    rice Repository record for Deposition temperature of evaporated permalloy films (opens in a new tab)

  7. AN EXPERIMENTAL STUDY OF FORCED COOLING ACROSS HEATED RECTANGULAR BLOCKS

    … and temperatures were measured with copper-constantan thermocouples. Assumptions such as insulated plates, constant heat production by the obstructions and uniform velocity profile at the entrance were made to render the problem controllable in the laboratory environment. Only laminar …

    rice Repository record for AN EXPERIMENTAL STUDY OF FORCED COOLING ACROSS HEATED RECTANGULAR BLOCKS (opens in a new tab)

  8. Vapor-liquid equilibria of the carbon tetrachloride, cyclohexane and isopropyl alcohol system.

    … Temperature was measured by means of a copper-constantan thermocouple. An azeotrope was found for carbon tetrachloride - isopropyl alcohol, cyclohexane - isopropyl alcohol and the ternary system. The Gibbs-Duhem equation for a binary system at constant pressure was used to check the consistency …

    ottawa-retro Repository record for Vapor-liquid equilibria of the carbon tetrachloride, cyclohexane and isopropyl alcohol system. (opens in a new tab)

  9. Measurement and control of deposition temperature of Gd-Co rf sputtered films

    A vacuum evaporated Chromel-Constantan Thin Film Thermocouple (TPTC) is developed and used to measure the deposition temperature of rf sputtered amorphous gadolinium-cobalt films. Deposition temperature can be varied with the type and the amount of thermal backing which affixes the substrates to …

    rice Repository record for Measurement and control of deposition temperature of Gd-Co rf sputtered films (opens in a new tab)

  10. Development of an apparatus to measure the thermal conductivity of polymer melts

    … were made with calibrated, differential, iron-constantan thermocouples. The thermal conductivity of polyethylene, polystyrene and nylon melts tested increased with increased temperature. The thermal conductivity of the polypropylene sample was temperature independent. Complexity of molecular …

    vt Repository record for Development of an apparatus to measure the thermal conductivity of polymer melts (opens in a new tab)

  11. Energy Resolved Phonon Scattering in Glasses

    … detectors. The phonon generators were thin film constantan heaters and the detectors were superconducting tunnelling heterojunctions. The ratio of the currents generated in the detectors by the phonon fluxes with and without the glassy film were calculated at different biases. By comparing these …

    glasgow Download PDF for Energy Resolved Phonon Scattering in Glasses (opens in a new tab)

  12. An experimental comparison of a pin stack to a conventional stack in a thermoacoustic prime mover

    … stack was constructed by by threading 75 micron constantan wire between the hot and cold heat exchangers 2312 times. Computer modeling with the program DeltaE predicts that a pin stack will significantly improve the efficiency of the prime mover. In the experiment the temperature gradient across …

    nps Repository record for An experimental comparison of a pin stack to a conventional stack in a thermoacoustic prime mover (opens in a new tab)

  13. Turbulent Mixing and Heat Exchange in a Parallel Stream of Air

    … and the intensity of turbulence, A copper-constantan thermocouple was used to measure temperature. A special subsonic wind tunnel was already available for this project, and only required a few design modifications to make it suitable for this project.

    sdstate Repository record for Turbulent Mixing and Heat Exchange in a Parallel Stream of Air (opens in a new tab)

  14. A temperature study of the V.P.I. training and research reactor (UTR-10)

    … this coolant temperature, an array of copper-constantan thermocouples was inserted between the individual plates of the fuel elements. The temperature of the coolant near the bottom and top of the 144 fuel plates was found using this thermocouple arrangement. These results were used to predict …

    vt Repository record for A temperature study of the V.P.I. training and research reactor (UTR-10) (opens in a new tab)

  15. The relation of bed depth, particle density, and particle size to the local coefficients of heat transfer of internally-heated fluidized beds of solids

    … were made with 20 B and S gage, iron-constantan thermocouples insulated with fiber-glass braid over glass wrap. Air varying in temperature from 80 to 85 °F and in humidity from 0.000 to 0.004 pound of water vapor per pound of dry air was used as the fluidizing medium.

    vt Repository record for The relation of bed depth, particle density, and particle size to the local coefficients of heat transfer of internally-heated fluidized beds of solids (opens in a new tab)

  16. DEVELOPMENT OF TEMPERATURE AND FLOW SENSORS FOR MICROFLUIDIC APPLICATIONS

    … of a micro thermal pulse flow sensor. A platinum-constantan (PT-NiCu) micro thermocouple was developed and fabricated using a three mask process. The micro fabrication protocols and procedures were developed for potentiostatically electroplating the constantan leg of the micro thermocouple. The …

    mcmaster Repository record for DEVELOPMENT OF TEMPERATURE AND FLOW SENSORS FOR MICROFLUIDIC APPLICATIONS (opens in a new tab)

  17. Refrigeration of the root zone to delay budbreak in grapes (Vitis vinifera)

    … one and two. Type T thermocopules (copper-constantan) attached to a datalogger and multiplexer were used to measure soil, water, and air temperatures. In experiment three, short wave radiation and relative humidity were measured using a portable weather station. The experiments indicated …

    ttu Repository record for Refrigeration of the root zone to delay budbreak in grapes (Vitis vinifera) (opens in a new tab)

  18. Variable temperature dewar for infrared absorption studies

    … The construction and calibration of a copper vs. constantan thermocouple is described. The thermocouple was used to measure the sample temperatures to an accuracy of about 1°K. Temperature variations of a few tenths of a degree could be detected. As a demonstration of the dewar's capabilities, an …

    ubc Repository record for Variable temperature dewar for infrared absorption studies (opens in a new tab) Download PDF for Variable temperature dewar for infrared absorption studies (opens in a new tab)

  19. Developmaent of a Wireless Force Sensor

    … FSL05N2C), Thin Film Flexi-force Sensor, constantan strain gage sensor and piezoresistive strain gage sensor. The sensors were subjected to different load cycle patterns at different rates to a maximum force of up to 200 N. The sensors were tested for their repeatability, linearity, …

    nus Repository record for Developmaent of a Wireless Force Sensor (opens in a new tab) Download file for Developmaent of a Wireless Force Sensor (opens in a new tab)

Page 1 of 3