Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"contact profilometry"”.

  1. Electropolishing Effects on Surface Roughness of Additively Manufactured Aluminum

    … changes are quantified using both portable contact profilometry and confocal laser scanning microscopy, enabling detailed analysis of topographical improvements. Comparative assessments between the two alloys and electrolyte systems offer insights into the electropolishing behavior of …

    concordia Download PDF for Electropolishing Effects on Surface Roughness of Additively Manufactured Aluminum (opens in a new tab)

  2. Evaluation Of zirconia-infused nano hybrid resin, composite resin, milled and autopolymerizing PMMA materials for fixed restorations: an in vitro study

    … by nanoindentation, surface roughness by contact profilometry, flexural strength by a three-point bending test, and fracture resistance using 2-mm and 4-mm loading configurations. Data were analyzed using one-way and two-way ANOVA with appropriate post hoc tests. Results: Significant …

    manitoba Repository record for Evaluation Of zirconia-infused nano hybrid resin, composite resin, milled and autopolymerizing PMMA materials for fixed restorations: an in vitro study (opens in a new tab)

  3. The Physico-chemical Characterisation of Bioactive Glass Air-abrasion on Human Enamel

    … analogue material (MacorTM) and white light profilometry. Standardised resin composite restorations created within MacorTM blocks, were removed in simulated clinical conditions and scanned using triangulation laser profilometry to investigate the effect of operating parameters on the …

    kings Repository record for The Physico-chemical Characterisation of Bioactive Glass Air-abrasion on Human Enamel (opens in a new tab) Download PDF for The Physico-chemical Characterisation of Bioactive Glass Air-abrasion on Human Enamel (opens in a new tab)

  4. Effect of full-contour Y-TZP zirconia surface roughness on wear of glass-based ceramics

    … 1.2 Hz for 25,000 cycles under a 3-kg load. Non-contact profilometry was used to measure antagonist height (μm) and volume loss (mm3). Qualitative data of the testing surfaces and wear tracks were obtained using SEM. Statistics were performed using one- and two-way ANOVAs (α=0.05). The results …

    iupui Repository record for Effect of full-contour Y-TZP zirconia surface roughness on wear of glass-based ceramics (opens in a new tab)

  5. In Vitro Investigation of Tooth Erosion

    … erosion and erosionabrasion models and use non-contact profilometry and Knoop microhardness to measure the change in the surface of enamel. The effects of different experimental protocols on profilometry and Knoop microhardness were investigated. Using the results from these preliminary studies, …

    kings Repository record for In Vitro Investigation of Tooth Erosion (opens in a new tab) Download PDF for In Vitro Investigation of Tooth Erosion (opens in a new tab)

  6. Shear thickening and defect formation in chemical mechanical polishing slurries

    … with 0.15 M KCl. Optical microscopy and non-contact profilometry linked slurry thickening behavior to scratching of a "polished" wafer. The thickened slurry generated up to 7x more scratches than a non-thickened slurry. Both slurry thickening and surface scratching were associated with a …

    colo-mines Repository record for Shear thickening and defect formation in chemical mechanical polishing slurries (opens in a new tab)

  7. Corrosion Product Growth Kinetics/Characteristics and Inhibitor Performance in CO2 Environments

    … was assessed using NPFLEX 3D optical non-contact profilometry and was found to be increasing through the addition of Ca2+ ions indicating that Ca2+ plays a role in promoting localised corrosion. XRD based calculations, along with FIB/EDX-line scans and SEM/EDX-point scans confirmed that …

    whiterose Download PDF for Corrosion Product Growth Kinetics/Characteristics and Inhibitor Performance in CO2 Environments (opens in a new tab)

  8. Crown Fatigue Resistance And Enamel Wear Of 3D Printed Resin Compared To Lithium Disilicate

    … 15 N load. Surface wear was evaluated using non-contact profilometry, and wear mechanisms were elucidated through scanning electron microscopy analysis of worn surfaces. Signs of abrasive or fatigue wear were identified, providing insights into the materials' wear resistance and durability. …

    uab Repository record for Crown Fatigue Resistance And Enamel Wear Of 3D Printed Resin Compared To Lithium Disilicate (opens in a new tab)

  9. Nondestructive Evaluation and Structural Health Monitoring of Manufacturing Flaws and Operational Damage in Composite Structures

    … NDE, X-ray micro computed tomography (CT) and contact profilometry methods. A pure mode guided wave excitation method using a variable angle beam transducer (ABT) as the excitation, and a phased array transducer (PAT) as the receiver, has been developed. This method has been used for exciting …

    south-carolina Repository record for Nondestructive Evaluation and Structural Health Monitoring of Manufacturing Flaws and Operational Damage in Composite Structures (opens in a new tab)

  10. The effect of triple antibiotic paste and EDTA on the surface loss and surface roughness of radicular dentin

    … quantified after various treatments using non-contact and contact profilometry, respectively. Data were analyzed by one-way analysis of variance (α = 0.05) Hypothesis: It was hypothesized that there would be a significant difference in surface loss or surface roughness between at least two …

    iupui Repository record for The effect of triple antibiotic paste and EDTA on the surface loss and surface roughness of radicular dentin (opens in a new tab)

  11. Antibacterial effects of sputter deposited silver-doped hydroxyapatite thin films

    … by measuring the surface profile using contact profilometry. Staphylococcus epidermidis (SE) and Pseudomonas aeruginosa (PA) adhesion studies were performed on plain titanium, titanium coated with hydroxyapatite, titanium coated with ~0.5 wt% silver-doped hydroxyapatite, and titanium …

    colostate Repository record for Antibacterial effects of sputter deposited silver-doped hydroxyapatite thin films (opens in a new tab)

  12. INFLUENCE OF TOPOGRAPHY OF ENDOVASCULAR STENT MATERIAL ON SMOOTH MUSCLE CELL RESPONSE

    … and restenosis. A model simulating the contact of stent material in the arterial wall was developed by utilizing 316L stainless steel of varying topography. Topography of as received 316L stainless steel was modified to get electropolished and micro-grooved surfaces using …

    clemson Repository record for INFLUENCE OF TOPOGRAPHY OF ENDOVASCULAR STENT MATERIAL ON SMOOTH MUSCLE CELL RESPONSE (opens in a new tab)

  13. On the uses of atmospheric and laser plasmas for biomedical applications

    … several investigative techniques (AFM, XRD, contact profilometry, Van der Pauw and water contact angle). These investigate the effects of growth parameters on physical and electrical properties of thin films grown on amorphous substrates at low temperatures as a function of growth pressure, …

    dcu Download PDF for On the uses of atmospheric and laser plasmas for biomedical applications (opens in a new tab)

  14. Strontium and Fluoride Co-substituted Calcium Phosphate Nanoparticles for Treatment of Dental Erosion and Caries

    … assessed using Knoop microhardness indenter, non-contact profilometry and SEM. Surface loss of calcium in 15.6 mM citric acid solution was quantified with ICP-OES. Polished HA discs were found to have surface microhardness above that of human enamel at 545 ± 20.8 KHN and show linear Ca2+ release …

    kings Repository record for Strontium and Fluoride Co-substituted Calcium Phosphate Nanoparticles for Treatment of Dental Erosion and Caries (opens in a new tab) Download PDF for Strontium and Fluoride Co-substituted Calcium Phosphate Nanoparticles for Treatment of Dental Erosion and Caries (opens in a new tab)

  15. Studium vlastností periodických mřížek vytvořených elektronovou litografii

    Tato práce se zabývá procesem tvorby reliéfních periodických struktur pomocí elektronové litografie. Popisuje, jak navrhnout tyto struktury pomocí počítače a následně je vytvořit elektronovým litografem. Dále se zabývá metodami, kterými můžeme tyto struktury měřit a vyhodnocovat. Tyto metody jsou …

    brno-tech Repository record for Studium vlastností periodických mřížek vytvořených elektronovou litografii (opens in a new tab)

  16. Přehled způsobů kvantifikace opotřebení u kyčelních kloubů

    Bakalářská práce se zabývá problematikou pozorování a kvantifikace opotřebení kyčelních náhrad. Nejprve byly popsány historické mezníky při vývoji kyčelních náhrad, typy používaných implantátů, různé druhy materiálů a životnost náhrad. Následně byla provedena rešeršní studie v oblasti pozorovacích …

    brno-tech Repository record for Přehled způsobů kvantifikace opotřebení u kyčelních kloubů (opens in a new tab)