Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"continuous slab"”.
-
Effects of Diaphragms in Continuous Slab and Girder Highway Bridges
Made available in DSpace on 2014-12-10T22:22:00Z (GMT). No. of bitstreams: 1 7317671.pdf: 3743816 bytes, checksum: 3264b26f07a0df68ed001a3d949ba8e9 (MD5) Previous issue date: 1973
-
Thermo-mechanical model of steel shell behavior in continuous slab casting
… an important influence on the final quality of continuously-cast steel slabs. In order to understand the thermal and mechanical behavior of the shell, a two-dimensional transient stepwise-coupled finite-element model has been developed. The model simulates a transverse section of the slab as it …
-
Characterization of heat transfer in the secondary cooling system of a continuous slab caster
… at several locations below the mould of a continuous slab-casting machine. In each secondary cooling zone, slab surface temperatures have been measured under normal and modified water spray cooling practices. A one-dimensional heat-transfer model of the casting process has been developed, …
-
Mathematical modeling of heat transfer in the meniscus region of the continuous slab casting mould
… and provided guidelines for improvements on slab surface quality and operating practice.
-
An Analysis of the Behavior of Short Two Span or Three Span Highway Bridges Subject to Pulsating Support Settlements
… to obtain the behavior for each section of the continuous slab.
-
Three-dimensional mathematical modeling of the thin slab continuous casting process
… state in the casting mold of thin slab continuous casters. The mold consists of two broad side walls and two narrow side walls all of which are water cooled. The upper portion of the broad side walls extend apart from each other so that a funnel-shaped chamber is defined. This …
-
Punching shear strength of reinforced concrete slab.
… of punching shear tests performed on a 2 x 2 bay continuous slab with/and without supplementary supports. On the basis of these tests, the code method of calculating the ultimate strength of interior, edge and corner column connections of flat slab were investigated. The thickness of the specimen …
-
Behavior of Skewed Continuous I Beam Bridge Structures
… the angle of skew affects the behavior of skew continuous slab-and-girder highway structures. Until now, no exact analysis for skew continuous structures was available in the literature. Consequently, an analytical investigation is needed in order to improve the design criteria of such …
-
Scalable Bayesian Computation for Modern Large Biomedical Data
… and theory to enable sampling from discrete-continuous mixture distributions such as those arising in spike-and-slab models for sparse estimation. By embedding the spike mass into the continuous slab density, we achieve simpler and more efficient samplers with direct connections to the …
-
Punching shear in edge and corner column slab connections of flat plate structures.
… behavior and strength of edge and corner column slab connections of flat plate structures subjected to shear force only, moment only as well as combined shear force and moment were investigated. A two bay by two bay flat plate structure (nine columns) and eight isolated edge column slab …
-
A Study of Bianisotropy in Split Ring Structures made with Graphene and Gold
… for varying thicknesses so that it behaves as a continuous medium in the long wavelength limit. The next goal is to retrieve the effective electromagnetic parameters like the permittivity, permeability and refractive index from this homogenized structure. This will lead to tuning the …
-
Simulation of steel/concrete composite structures in fire.
… of significant parametric studies including slab thickness and secondary beam connection strength and stiffness. The concrete floor slab element has also been extended to a layered flat shell element allowing the inclusion of material non-linearities, thermal bowing, thermal degradation, …
-
Minimum Number of Accelerograms for Time-History Analysis of Typical Highway Bridges
… in Montreal. The bridges included a three-span continuous concrete slab bridge and a three-span continuous slab-girder type bridge. These two bridges are considered to be representative of typical highway bridges in Quebec. A number of response parameters, such as, the deck displacement, bearing …
-
The real strength of laterally restrained reinforced concrete slabs
… enhancement exhibited by laterally restrained slab system . This strength enhancement is in excess of that estimated by standard flexural and shear design methods.<br/><br/>Although of the fact that the consideration of CMA in design can lead to substantially reduced quantities of flexural …
-
Fracture analysis of bridges by spline finite strip method
… analysis of different types of bridges, such as slab bridge, continuous slab bridge, single - cell box girder bridge and continuous bridge with top-open box girder, are successfully conducted using these crack strips. The leading diagonal terms are replaced by large numbers to deal with those …
-
Argon Bubble Behavior in Slide-Gate Tundish Nozzles During Continuous Casting of Steel Slabs
… employed method to reduce nozzle clogging in the continuous casting process. It also affects casting operation and product quality by changing the flow pattern in the nozzle and mold. The current work combines mathematical modeling and experiments to investigate the argon bubble behavior in …
-
Response of Continuous Steel I-Girder Bridges Subject to Temperature Variation
Thermal deformation of the superstructure in continuous slab-on-girder bridges must be freely permitted to avoid potential adverse behavior due to the development of thermal forces. The use of fixed and guided bearings can introduce a significant amount of restraint against thermal deformation …
-
Studies in heat and mass transfer
… work was carried out in a pilot plant continuous fibre drier. The fibre, moving through the drier, becomes compressed into the form of a continuous slab of rectangular section. In the drier, the air flows at right angles to one of the two larger surfaces of the fibre tow, giving the …
-
Experimental and analytical evaluation of disproportionate collapse flat-plate buildings
Reinforced concrete flat plate buildings without continuous integrity reinforcement may be vulnerable to disproportionate collapse if a supporting structural member was lost in an abnormal event. This research forces on the evaluation of potential of disproportionate collapse in older flat-plate …
-
Analysis and Design of Link Slabs in Jointless Bridges With Fibre-Reinforced Concrete
… One of the alternatives is the use of link slab in a jointless bridge, which connects the adjacent bridge deck slabs at the pier, forming a continuous slab across the bridge spans. While the link slab system can provide the benefits of a continuous bridge deck, refinement of the design and …
Page 1 of 2