Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 45 for “"controlled ventilation"”.

  1. Experimental and simulation study of demand controlled ventilation

    … for a multizone building utilizing three ventilation control strategies. The three strategies are occupancy-based demand controlled ventilation (DCV), carbon-dioxide based DCV and constant ventilation. The study compares the building's energy consumption using the three methods for summer, …

    iastate Repository record for Experimental and simulation study of demand controlled ventilation (opens in a new tab)

  2. Demand Controlled Ventilation Energy Savings for Air Handling Units

    Heat, cooling, and ventilation units are major energy consumers for commercial buildings, they can consume as much as 50% of the total annual power usage of a building. Coherent management of an air handling system’s energy is a key factor of reducing the energy costs and CO2 emissions that are …

    iupui Repository record for Demand Controlled Ventilation Energy Savings for Air Handling Units (opens in a new tab)

  3. Demand Controlled Ventilation: Use in Calgary and Impact of Sensor Location

    Demand controlled ventilation (DCV) is used to reduce the amount of energy required to condition outdoor air introduced into a building based by monitoring occupancy. This thesis reports the hours DCV is used in an existing building in Calgary. Results showed DCV was used approximately 20% of …

    calgary Repository record for Demand Controlled Ventilation: Use in Calgary and Impact of Sensor Location (opens in a new tab)

  4. THE EFFICACY OF SIGHS IN THE CHRONIC OBSTRUCTIVE PULMONARY DISEASED PATIENT UNDERGOING ANESTHESIA AND CONTROLLED VENTILATION

    This study examined the hypothesis that sighing decreases the alveolar to arterial oxygen tension gradient, (A-a)DO2 (see definitions), in chronic obstructive pulmonary diseased (COPD) patients undergoing general anesthesia as compared to COPD patients not sighed. A research question was also …

    ku Repository record for THE EFFICACY OF SIGHS IN THE CHRONIC OBSTRUCTIVE PULMONARY DISEASED PATIENT UNDERGOING ANESTHESIA AND CONTROLLED VENTILATION (opens in a new tab)

  5. MEASURING OCCUPANT CONTROLLED VENTILATION AND COOKING FREQUENCY TO AID IN MODELING ENERGY PERFORMANCE OF NORTHERN MICHIGAN HOMES

    … and indoor air quality. We explore how home ventilation strategies, heating systems, and weatherization levels in rural homes interact. As part of a larger study on air quality, 17 homes participated in the study. Specifically, this research shows the results and methods for monitoring …

    mtu Repository record for MEASURING OCCUPANT CONTROLLED VENTILATION AND COOKING FREQUENCY TO AID IN MODELING ENERGY PERFORMANCE OF NORTHERN MICHIGAN HOMES (opens in a new tab)

  6. Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems

    Demand-Controlled Ventilation (DCV) is a ventilation control strategy that provides automatic reduction of outdoor air intake below design rates when the actual occupancy of spaces served by the system is less than design occupancy. This research aimed to propose CO2 and occupancy sensor-based DCV …

    nebraska Repository record for Simulation-based study on CO2-based demand controlled ventilation strategies for multiple zone variable air volume systems (opens in a new tab)

  7. A Demand-Controlled Ventilation (DCV) Systems Approach Towards Energy-Efficient Management for Improved Indoor Air Quality (IAQ)

    … for educational environments, as poor ventilation and inadequate air filtration have been linked to adverse health effects and reduced cognitive performance. In commercial spaces, insufficient IAQ can lead to occupants' discomfort, increased sick leave, and lower productivity, whereas …

    vt Repository record for A Demand-Controlled Ventilation (DCV) Systems Approach Towards Energy-Efficient Management for Improved Indoor Air Quality (IAQ) (opens in a new tab)

  8. Feed-Forward Neural Network (FFNN) Based Optimization Of Air Handling Units: A State-Of-The-Art Data-Driven Demand-Controlled Ventilation Strategy

    Heating, ventilation and air conditioning systems (HVAC) are the single largest consumer of energy in commercial and residential sectors. Minimizing its energy consumption without compromising indoor air quality (IAQ) and thermal comfort would result in environmental and financial benefits. …

    iupui Repository record for Feed-Forward Neural Network (FFNN) Based Optimization Of Air Handling Units: A State-Of-The-Art Data-Driven Demand-Controlled Ventilation Strategy (opens in a new tab)

  9. Energy renovation and healthy indoor environment in green buildings -Impact of dynamic shading and demand controlled ventilation on occupant health and comfort

    … energy use of existing buildings, such as demand controlled ventilation and dynamic shading. However, when they are implemented they can also have an on impact the comfort and health of the building’s occupants. Discomfort in the domains of thermal comfort, visual comfort and air quality can cause …

    chalmers Repository record for Energy renovation and healthy indoor environment in green buildings -Impact of dynamic shading and demand controlled ventilation on occupant health and comfort (opens in a new tab)

  10. System Design and Energy Performance of Ventilation Systems in Small Residential Buildings: A Comparison Study of FTX-Ventilation and Termite Ventilation with Demand and Seasonal Controlled Ventilation

    Ventilation is one of several subsystems that are necessary for a building to function as intended from an indoor climate and energy point of view. FTX-ventilation are advocated in low-energy buildings, both from an energy and indoor climate perspective. Some actors in the industry claim that …

    chalmers Repository record for System Design and Energy Performance of Ventilation Systems in Small Residential Buildings: A Comparison Study of FTX-Ventilation and Termite Ventilation with Demand and Seasonal Controlled Ventilation (opens in a new tab)

  11. Behovsstyrd Ventilation På Kryssningsfartyg - Potential till användning och energibesparing

    … The suitability of implementing demand-controlled ventilation on board cruise vessels is examined in the following literature review. This type of ventilation strategy is sometimes used in buildings ashore. Three sub questions where used answer the main question about the suitability, …

    chalmers Repository record for Behovsstyrd Ventilation På Kryssningsfartyg - Potential till användning och energibesparing (opens in a new tab)

  12. Vergleich der kardiovaskulären Funktion bei spontan atmenden und künstlich beatmeten Pferden unter Isofluran/Medetomidin-Anästhesie

    … were assigned to either spontaneous breathing or controlled ventilation to mild hypercapnia (arterial partial pressure of carbon dioxide 50-60 mmHg). Heart rate, respiratory rate, intraarterial blood pressure and composition of in- and expiratory gases were recorded every 5 minutes. Arterial blood …

    zurich Repository record for Vergleich der kardiovaskulären Funktion bei spontan atmenden und künstlich beatmeten Pferden unter Isofluran/Medetomidin-Anästhesie (opens in a new tab) Restricted access

  13. Optimization of control device locations and sizes in mine ventilation systems

    … an improved methodology for solving the semi-controlled ventilation network problem. After analysis and consideration of the objective and legal, technical and operation convenience factors, the semi-controlled network problem is formulated through a nonlinear nonconvex programming model. …

    vt Repository record for Optimization of control device locations and sizes in mine ventilation systems (opens in a new tab)

  14. Optimization of Building Integrated Phase Change Materials Using Experiments and Simulation

    … prevent overheating, a reduced window size and controlled ventilation system were added. Experimental testing compared the thermal performance of optimized PCM cement tiles, uniformly distributed PCM tiles, and pure cement tiles. Results between the optimized and uniform PCM tiles showed a 13.5% …

    carleton Repository record for Optimization of Building Integrated Phase Change Materials Using Experiments and Simulation (opens in a new tab)

  15. Η επίδραση τριών διαφορετικών χειρισμών έκπτυξης κυψελίδων (recruitment maneuvers) στην ανταλλαγή αερίων αρτηριακού αίματος ασθενών με πρώιμο ARDS

    … of oxygenation caused by an inhomogeneous ventilation-perfusiondistribution and an increase in shunt fraction. The amount of aerated lung is markedlyreduced due to alveolar collapse and flooding. The only intervention found to reducemortality from ARDS is an approach to mechanical …

    greece Repository record for Η επίδραση τριών διαφορετικών χειρισμών έκπτυξης κυψελίδων (recruitment maneuvers) στην ανταλλαγή αερίων αρτηριακού αίματος ασθενών με πρώιμο ARDS (opens in a new tab)

  16. Βελτιστοποίηση της αναπνευστικής υποστήριξης στη νεογνική περίοδο

    … number of methods and techniques of mechanical ventilation and respiratory support in general are now available for neonates. Neonates, especially premature ones, are at high risk of developing respiratory muscle fatigue, due to reduced oxidative capacity of their respiratory muscles. It is …

    greece Repository record for Βελτιστοποίηση της αναπνευστικής υποστήριξης στη νεογνική περίοδο (opens in a new tab)

  17. Non-invasive measurement of respiratory mechanics and work of breathing

    … invasive, requiring either a sedated patient on controlled ventilation to abolish spontaneous respiratory muscle activity or measurement of oesophageal and gastric pressures. The aim of this thesis was to explore the feasibility and potential clinical value of non-invasive measurements of …

    glasgow Download PDF for Non-invasive measurement of respiratory mechanics and work of breathing (opens in a new tab)

  18. Ventilación controlada por volumen vs. ventilación controlada por presión en pacientes sometidos a ventilación de un solo pulmón

    The one lung ventilation (OLV) have problems as well increase of pressures in the airway and the shunt. This changes can be influenced by the ventilation mode choice. The ventilation controlled by pressure (VCP) is an alternative way widely used in patients with respiratory failure by its …

    rosario Repository record for Ventilación controlada por volumen vs. ventilación controlada por presión en pacientes sometidos a ventilación de un solo pulmón (opens in a new tab)

  19. Comparison of the energy and economic feasibility of different building systems.

    … (GSHP), Variable Air Volume (VAV) RTU, Demand Controlled Ventilation (DCV), and Natural Daylighting.</p> <p>Each system will be modeled in two different building types. The first being a standard 100 ft by 100 ft office building with a flat roof. The second building type will be two long narrow …

    iastate Repository record for Comparison of the energy and economic feasibility of different building systems. (opens in a new tab)

Page 1 of 3