Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 17 of 17 for “"conventional impression"”

  1. Accuracy of computerized and conventional impression-making procedures of straight and tilted dental implants

    … evaluates the accuracy of computer-aided and conventional impression-making procedures of straight and tilted dental implants in a standardized in vitro setting.<br><br>Two edentulous acrylic resin study models with four interforaminally positioned implant analogs were fabricated. Model 1 had …

    freiburg-diss Repository record for Accuracy of computerized and conventional impression-making procedures of straight and tilted dental implants (opens in a new tab)

  2. Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for full-arch implant-supported prostheses: an in-vitro study

    … is to measure and compare the accuracy of the conventional impression, the intraoral scanner, and the photogrammetry techniques for full-arch implant-supported dental prostheses at the abutment level. METHODS: An edentulous maxillary master model containing 6 implant abutment replicas (RP …

    bu Repository record for Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for full-arch implant-supported prostheses: an in-vitro study (opens in a new tab)

  3. Fitting of removable partial denture frameworks obtained using conventional impression techniques or intraoral scanning: study protocol for a randomized clinical trial

    Ao longo dos últimos anos, os métodos digitais têm ganhado cada vez mais relevância em diferentes aspetos da prática diária na área da prostodontia, nomeadamente nos processos de diagnóstico e no delineamento de planos de tratento, no design e fabrico de restaurações, guias, stents e dispositivos, …

    coimbro Repository record for Fitting of removable partial denture frameworks obtained using conventional impression techniques or intraoral scanning: study protocol for a randomized clinical trial (opens in a new tab)

  4. Time efficiency of digital impression systems

    … evaluate the time efficiency of computer aided impression making procedure among various digital intraoral scanning systems. Furthermore, a comparison of time efficiency between the digital and conventional impression making method was conducted. Three different intraoral scanners (iTero, LAVA …

    freiburg-diss Repository record for Time efficiency of digital impression systems (opens in a new tab)

  5. On titanium frameworks and alternative impression techniques in implant dentistry

    … in the edentulous jaw and to test a digitized impression technique to optimize material characteristics and clinical and laboratory procedures.Materials and Methods: Two different kinds of laser-welded titanium frameworks and one type of digitized computer numeric controlled (CNC)-milled …

    goteborg Repository record for On titanium frameworks and alternative impression techniques in implant dentistry (opens in a new tab)

  6. Essays on applied mircoeconomics and finance

    … seats to applicants. Chapter 1 shows that the conventional impression holds in the short-run that review manipulation makes review systems less informative. In the long-run, however., a manipulated review system can contain the same level of information as an un-manipulated counterpart. I …

    mit Repository record for Essays on applied mircoeconomics and finance (opens in a new tab)

  7. A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction

    Introduction: Impressions play an important role in dentistry and its specialties. Recent technological advances have made intraoral scans and digital models a possibility, and a promising alternative to conventional alginate impressions. Several factors should be examined when considering an …

    ohiolink Repository record for A Comparison of Digital Intraoral Scanners and Alginate Impressions: Time & Patient Satisfaction (opens in a new tab)

  8. Accuracy of Intra-oral Scanner Impression for Different Post-Space Lengths

    … lengths 6, 8, and 10 mm and compare it with conventional impressions using three-dimensional software. Materials and methods: A total of forty-five root typodont teeth (Maxillary central incisors) were selected. Root canal treatment and tooth preparation for the crown were performed on all …

    penn Repository record for Accuracy of Intra-oral Scanner Impression for Different Post-Space Lengths (opens in a new tab)

  9. Time efficiency of digitally and conventionally produced single-unit restorations

    … digital chairside and labside workflows with a conventional workflow for single-unit restorations. The time efficiency in this specific sense was defined as the time, which has to be spent in a dental office by a dental professional performing the relevant steps. A model with interchangeable …

    zurich Repository record for Time efficiency of digitally and conventionally produced single-unit restorations (opens in a new tab)

  10. A comparison of crown marginal fit fabricated using digital and conventional methods

    … fit of crowns fabricated using digital and conventional methods. Materials and Methods. A maxillary right second bicuspid, set in a typodont (Frasaco, Greenville, N.C., USA), was prepared for a ceramic crown. The maxillary typodont was then digitized, using a 3Shape D700 lab scanner (3Shape …

    ubc Repository record for A comparison of crown marginal fit fabricated using digital and conventional methods (opens in a new tab)

  11. Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis

    … some studies indicate the superiority of digital impression systems in terms of the marginal accuracy of ceramic restorations, whereas others show that the conventional method provides restorations with better marginal fit than fully digital fabrication. Which impression method provides the lowest …

    greece Repository record for Evaluation of the marginal fit of single-unit, complete-coverage ceramic restorations fabricated after digital and conventional impressions: a systematic review and meta-analysis (opens in a new tab)

  12. Assessing the passive fit of milled titanium substructure produced from different digitalimpression techniques.

    … titanium framework obtained from different impression techniques, and the abutment replica of the patient model.Materials and Methods: Four implant Simulated Patient Model was duplicated from a demonstration resin model. The implant impression of the edentulous arch was obtained using 6 …

    ohiolink Repository record for Assessing the passive fit of milled titanium substructure produced from different digitalimpression techniques. (opens in a new tab)

  13. In Vitro Comparative Study Between Full-Arch Conventional Implant Impressions and Full-Arch Digital Implant Impressions with Snap-on Scan Bodies

    Statement of Problem: Digital impression techniques are widely used in everyday cases. There is sufficient evidence to support this technique in partially edentulous patients but the evidence supporting the use of intraoral scanners (IOS) in restorative digital workflows for edentulous patients is …

    penn Repository record for In Vitro Comparative Study Between Full-Arch Conventional Implant Impressions and Full-Arch Digital Implant Impressions with Snap-on Scan Bodies (opens in a new tab)

  14. Vergleichende Untersuchung von intraoraler und extraoraler Digitalisierung nach Modellherstellung mit CEREC-3D®

    Durch den Einsatz von CAD/CAM-Technologien sollen potenzielle Fehlerquellen der handwerklich-manuellen Herstellung zahnmedizinischprothetischer Restaurationen eliminiert werden. Grundlage für die Fertigung einer prothetischen Restauration mittels CAD/CAM ist eine möglichst genaue Digitalisierung …

    qucosa-diss Repository record for Vergleichende Untersuchung von intraoraler und extraoraler Digitalisierung nach Modellherstellung mit CEREC-3D® (opens in a new tab)

  15. Técnica de impressão digital vs. convencional: comparação em desdentados totais

    Introdução: Em prótese total removível, a impressão convencional permite obter modelos de gesso com uma reprodução ótima dos tecidos orais. O aparecimento de scanners intraorais trouxe, todavia, a introdução na prática clínica de um método de impressão digital, eliminando a impressão física dos …

    coimbro Repository record for Técnica de impressão digital vs. convencional: comparação em desdentados totais (opens in a new tab)

  16. Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses.

    … OR “removable prostheses” AND (“digital impression technique” OR “CAD/CAM”) NOT “fixed prostheses”, seguida de uma segunda revisão nas bases de dados PubMed, Web of ScienceTM, B-On, ClinicalKey® e ScienceDirect com a combinação: “CAD/CAM” AND “Intraoral digital impression” AND …

    coimbro Repository record for Accuracy of intraoral digital impressions and conventional impressions: at the level of partial removable prostheses. (opens in a new tab)