Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 13 of 13 for “"converging flow"”.
-
Converging flow between two flat disks
… numerical solution to the radial non-swirling inflow between two flat (parallel circular) disks.
-
Laboratory Modelling of the Various Components of Backward Erosion Piping Behavior Due to Converging Flow With Different Constricted Outlets
… the three dimensional aspect of it as the water flowing from all directions toward the exit. Therefore, this problem needed to be simulated in a three dimensional model. The objectives of the research are to predict the critical gradient in the sand boil throat due the suspended material which …
-
A study of fluid flow entering a sharp-edged channel
… to a variation of a two dimensional case of converging flow in a capillary as originally derived by Oka and proposed by Philippoff. In addition velocity profiles were taken in the entrance region. Furthermore, the effect of temperature gradients in the slit region with their resulting optical …
-
Behavior of Polymer Solutions and Melts in Shearing and Elongational Flow Using Streak Photography and Birefringence
… (polyacrylamide solution) fluid undergoing flow past a radially oriented cylinder in both a converging and uniform flow field. The glycerin and polyacrylamide solutions are found to follow Newtonian and power law behavior, respectively, in Poiseuille flow between parallel plates and the …
-
Fan noise reduction from a supersonic inlet
… face. In addition, the new design also uses a converging flow passage in the auxiliary doors in order to take advantage of the noise attenuation due to the choking effect. Both aerodynamic and acoustic measurements are taken in the experiments. The results show that when compared to the …
-
Viscoelastic Fluid Flow Past a Submerged Spheroidal Body (Birefringence, Free Energy)
… to study the problem of homogeneous axisymmetric flow of a third order fluid past a spheriodal body. The numerical solution was shown to agree well with existing analytical solutions for several limiting cases (such as flow past a sphere), and was used to investigate the effects of the (a) body …
-
Reduced fan noise radiation from a supersonic inlet
… a new inlet door geometry designed to reduce flow distortion and noise radiation. The new door geometry uses door passages with increased circumferential span to improve the distribution of the flow entering through the doors. In addition, the new design employs sonic flow velocity at the …
-
Solid particle transport behavior and the effect of aerosol mass loading on performance of a slit virtual impactor
… particles seeded in the virtual impactor flow. It was observed from these trajectories that for smaller inertia particles essentially followed the flow streamlines, whereas higher inertia particles tend to deflect from their initial streamlines. These transport characteristics were used to …
-
In-situ Visualization and Quantification of Polymer Crystallization under Complex Flows during Foam Extrusion Processing
… tandem extrusion system equipped with a conical converging flow channel and a high temperature/pressure visualization chamber were employed. Using the developed system, effect of processing parameters on crystallization was elucidated. These parameters included the processing temperature, the …
-
Melting Relationship of The Rock Creek Flow, Columbia River Basalts, Idaho
The Rock Creek Flow, a Miocene tholeiitic basalt of the Columbia River Plateau Province, is a geographically well defined flow more than 400 feet thick and belonging to the "Basaltic flood" type. Having received little prior geologic attention, it is now the object of an eight-university study with …
-
New Solutions for Two-Cell Vortices
… integration software. It is found that along the converging flow direction, the temperature first decreases (in the outer cell), increases within the inner cell, and then flattens close to the vortex center. The cause of this effect is identified to be due to the interplay of dilation-contraction …
-
Venturi Meter Performance When Installed on the Branch of a Tee Junction with Converging Run Flow
Venturi flow meters are often installed downstream of disturbances such as a tee junction, valve, or elbow. In such a case, a laboratory calibration may be needed to measure the Venturi meter’s performance under said limitations so that accurate metering is achieved. However, in some cases, …
-
Foam control utilizing hydraulic forces of an accelerated liquid surface and characterization of durable foams by application of an external force
… during carriage as a result of an accelerated converging flow through a down flow draft tube. The principles of the method were based on the creation of differential shearing forces at the foam-liquid interface to cause disruption of foam at the interface and subsequent re-entrainment during …