Results 1 to 20 of 41 for “"cooling coil"”

  1. Open-loop frequency response analysis of a jacketed kettle with internal heating/cooling coil

    … of a jacketed kettle with internal heating/cooling coils and glasteel thermowell. This system was first analyzed mathematically by deriving transfer functions for each component and then combining all component equations together to give the overall system transfer function. The mathematical …

    njit Repository record for Open-loop frequency response analysis of a jacketed kettle with internal heating/cooling coil (opens in a new tab)

  2. The effect of favourable and unfavourable frost on air cooling coil performance : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology, at Massey University

    The most common type of air cooling coil used in the refrigeration industry is the finned tube heat exchanger. The performance of such coils can be greatly hindered by frost formation, which will occur when the coil surface temperature is both below the dewpoint of the air passing over it, and …

    massey Repository record for The effect of favourable and unfavourable frost on air cooling coil performance : a thesis presented in partial fulfilment of the requirements for the degree of Master of Technology, at Massey University (opens in a new tab)

  3. Heat Transfer Performance and Piping Strategy Study for Chilled Water Systems at Low Cooling Loads

    … system has the problem of low delta-T under low cooling loads. When the chilled water flow is much lower than the design conditions at low cooling loads, it may lead to the laminar flow of the chilled water in the cooling coils. The main objective of this thesis is to explain the heat transfer …

    tamu Repository record for Heat Transfer Performance and Piping Strategy Study for Chilled Water Systems at Low Cooling Loads (opens in a new tab)

  4. EnergyPlus Simulation of Single-Coil Twin-Fan Air Conditioning System

    … energy performance of the newly-developed Single-Coil Twin-Fan (SCTF) air conditioning system. The objectives of this project were to develop a customized module of the energy efficient SCTF system, validate the model using industry-accepted simulation verification methods, and implement the …

    nus Repository record for EnergyPlus Simulation of Single-Coil Twin-Fan Air Conditioning System (opens in a new tab)

  5. Test of a 400 Pound Refrigerating Plant

    … transmission per sq. ft. of surface through the cooling coil.

    marquette Repository record for Test of a 400 Pound Refrigerating Plant (opens in a new tab)

  6. Development and Analysis of Model Based Economizer Strategies

    … agreed within 25%. Both detailed and bypass coil models were evaluated for potential use in the model based economizer strategies. Energy and peak load analyses were performed for three benchmark buildings using five economizer strategies for 15 US climatic conditions. The impact of sensor …

    okstate Repository record for Development and Analysis of Model Based Economizer Strategies (opens in a new tab)

  7. Development of an adaptive fuzzy logic controller for HVAC system

    <p>An adaptive approach to control a cooling coil chilled water valve operation, called adaptive fuzzy logic control (AFLC), is developed and validated in this study. The AFLC calculates the error between the supply air temperature and supply air temperature set point for air in an air handling …

    iastate Repository record for Development of an adaptive fuzzy logic controller for HVAC system (opens in a new tab)

  8. Coil Condensation Detection For Humidity Control

    … on an AHU, it detects water condensing off the cooling coil as the temperature of the air drops below the dew point. Electronics were designed to provide the 0.25 V, 131 kHz current required and to obtain a 0 V output when dry and a 5 V output when wet. A field reliability test was successfully …

    tamu Repository record for Coil Condensation Detection For Humidity Control (opens in a new tab)

  9. Thermo-fluid characteristics of fin-and-tube heat exchangers with various fin details for air conditioning applications

    … the air conditioning plant is the fin-and-tube cooling coil, which is investigated here. The main focus of the work is concerned with the analysis of fin-and-tube cooling coils having two classes of passive enhancement techniques known as corrugated and turbulated fins with particular reference …

    northumbria Repository record for Thermo-fluid characteristics of fin-and-tube heat exchangers with various fin details for air conditioning applications (opens in a new tab)

  10. Optimising mine cooling system performance through monitoring and analysis

    … Mines mitigate this heat load with large cooling systems to provide safe working conditions. These cooling systems are therefore critical in effective mine operations and are an area in need of optimisation through monitoring and analysis. This study implemented a novel application of the …

    nwu-za Repository record for Optimising mine cooling system performance through monitoring and analysis (opens in a new tab)

  11. FIELD STUDY OF ULTRAVIOLET GERMICIDAL IRRADIATION SYSTEMS FOR COOLING COILS IN A HOT AND HUMID CLIMATE - ENERGY AND DISINFECTION ANALYSIS

    Microbial growth on cooling coil surfaces is associated with deteriorated indoor air quality (IAQ) and energy penalty. The humid and cool environments around cooling coils, especially in a year-round hot and humid climate like Singapore, make them ideal places for microbial growth. Although …

    nus Repository record for FIELD STUDY OF ULTRAVIOLET GERMICIDAL IRRADIATION SYSTEMS FOR COOLING COILS IN A HOT AND HUMID CLIMATE - ENERGY AND DISINFECTION ANALYSIS (opens in a new tab)

  12. Empirical validation of building energy simulation software:: EnergyPlus

    … tests were conducted to provide variation in cooling coil operating conditions and chiller loading. For one test an electric humidifier was used to provide additional latent loading for the system. EnergyPlus models were developed for each set of test conditions (including weather data) and …

    iastate Repository record for Empirical validation of building energy simulation software:: EnergyPlus (opens in a new tab)

  13. Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency

    … performance of the newly developed compartmented cooling coil of the Single Coil Twin Fan air-conditioning and air distribution system. A fundamental mathematical model has been formulated and validated based on a comprehensive experimental methodology. Efforts have been taken to derive unique …

    nus Repository record for Mathematical modelling and performance evaluation of compartmented coil for enhanced IAQ and energy efficiency (opens in a new tab)

  14. Simulation of Advance Thermal Processes in Buildings to Optimise Energy Performance and Costs

    … on energy consumption, particularly at the cooling coil section; 2) to develop a simplified calculation methodology/tool based on a steady-state analysis in order to roughly calculate the energy demands/costs and primary energy in such arenas; 3) to develop a price-based control approach for …

    aalto Repository record for Simulation of Advance Thermal Processes in Buildings to Optimise Energy Performance and Costs (opens in a new tab)

  15. Precooling Ventilation Air for Hospital Operating Rooms and the Affects on Terminal Box Reheat

    … system, and AL2, which incorporates a pre-cooling coil and discharge air temperature (DAT) reset strategy. Using EnergyPlus simulations, each system was modeled across multiple U.S. cities representing a wide range of climate zones. Results show that AL2 significantly reduces plant energy …

    uno Repository record for Precooling Ventilation Air for Hospital Operating Rooms and the Affects on Terminal Box Reheat (opens in a new tab)

  16. First Law Energy Balance as a Data Screening Tool

    … plus the electric gains in the building and the cooling coil loads. It then applies a first law energy balance in conjunction with the concepts of analytical redundancy (AR) and trend checking to demonstrate that measured values of BL E can be compared with the simulated characteristic ambient …

    tamu Repository record for First Law Energy Balance as a Data Screening Tool (opens in a new tab)

  17. Laminar-flow Liquid-to-air Heat Exchangers - Energy-efficient Display Cabinet Applications

    … systems being converted to systems with indirect cooling by means of a liquid secondary refrigerant. The cooling coil is an important component in a display cabinet and traditionally, different kinds of tube-coils, with aluminium fins on expanded circular copper tubes, have been used. Many …

    lund Repository record for Laminar-flow Liquid-to-air Heat Exchangers - Energy-efficient Display Cabinet Applications (opens in a new tab)

  18. Dynamic Modeling and Gain Scheduling Control of a Chilled Water Cooling System

    … and Gain Scheduling Control of a Chilled Water Cooling System Jun Liu In this thesis, a dynamic model of a chilled water (ChW) cooling system with a stratified ChW tank was developed. The model-based analysis of the energy consumption and the cost under different control strategies were studied. …

    concordia

  19. Calibration of a Building Energy Model Using Measured Data for a Research Center

    … ii) the supply air temperature and iii) the cooling coil load. The evaluation of the calibration quality is proposed to be performed in three stages: i) graphical representation; ii) statistical indices (RMSE, CV-RMSE, NMBE); and iii) paired difference statistical hypothesis testing. A …

    concordia