Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 31 for “"copper pipes"”.

  1. Proteomic and genomic characterization of the influence of copper on Legionella pneumophila and the drinking water microbiome

    … understand this unique and important organism. Copper is a natural antimicrobial that can be present in drinking water due to passive release from copper pipes or intentionally dosed (e.g., copper-silver ionization systems) for microbial control. However, some L. pneumophila strains have …

    vt Repository record for Proteomic and genomic characterization of the influence of copper on Legionella pneumophila and the drinking water microbiome (opens in a new tab)

  2. Influences of Water Chemistry and Flow Conditions on Non-Uniform Corrosion in Copper Tube

    … types of non-uniform pitting corrosion in copper tube, specifically in waters with high chlorine and a high pH. These two parameters can further act synergistically to alter pitting propensities in copper pipes subjected to this type of water. A preliminary short-term experiment considered …

    vt Repository record for Influences of Water Chemistry and Flow Conditions on Non-Uniform Corrosion in Copper Tube (opens in a new tab)

  3. Timing Effects on Fragmentation by Blasting

    … similar tests in blocks but by placing copper pipes in the blast holes to control the gas propagation through the blast zone. Although gas penetration did not seem to be fully inhibited by the copper pipes, the new design yielded different results in the delay range which had produced …

    queens Repository record for Timing Effects on Fragmentation by Blasting (opens in a new tab)

  4. Linkage Between Characteristics of Premise Plumbing Systems and Microbial Quality of Stagnant Drinking Water

    … tap water for 15s for every 100ft of 0.5in copper piping in order to reduce microbial contamination is a simple potential risk-mitigation strategy for premise plumbing users.</p> <p>Further analyses focused on the chlorine decay rates in copper pipes. Chlorine was found to decay faster in …

    ut-knoxville Repository record for Linkage Between Characteristics of Premise Plumbing Systems and Microbial Quality of Stagnant Drinking Water (opens in a new tab)

  5. The effect of pH adjustment on the internal corrosion rate of cast iron and copper water distribution pipes

    … on internal corrosion of cast iron and copper water distribution pipes. The Greater Vancouver Regional District uses surface lakes as its potable water source. As confirmed by chemical water characteristics monitoring, the supplied tap water has several of the attributes of an aggressive …

    ubc Repository record for The effect of pH adjustment on the internal corrosion rate of cast iron and copper water distribution pipes (opens in a new tab) Download PDF for The effect of pH adjustment on the internal corrosion rate of cast iron and copper water distribution pipes (opens in a new tab)

  6. Role of Water Chemistry in Lead Release during Drinking Water Supply and Augmentation

    … corrosion products formed on the interior of the pipes. Therefore, it is critical to advance our understanding of the extent of lead released from different lead-based plumbing materials at equilibrium and the ability to control lead when it exceeds the regulatory levels. Lead measured in the 1st …

    wustl Repository record for Role of Water Chemistry in Lead Release during Drinking Water Supply and Augmentation (opens in a new tab)

  7. Non-Uniform Copper Corrosion in Potable Water: Theory and Practice

    … flow can influence non-uniform corrosion of copper pipe (Rushing 2002, Marshall 2004), it has never previously been considered a primary contributor to the problem. This work is the first to describe a fundamentally important phenomenon in aqueous non-uniform corrosion: flow electrification. …

    vt Repository record for Non-Uniform Copper Corrosion in Potable Water: Theory and Practice (opens in a new tab)

  8. The Effects of PET-Lined and Epoxy-Coated Lead and Copper Service Lines on Metals Leaching, Total Organic Carbon, and Chlorine Residual in Drinking Water

    … collected under the requirements of the Lead and Copper Rule (LCR). Full LSL replacement can be expensive if trenching is required. Additionally, the LCR does not require replacement of the homeowner-owned portion of the LSL. When utilities replace only their portion (partial replacement), the …

    ku Repository record for The Effects of PET-Lined and Epoxy-Coated Lead and Copper Service Lines on Metals Leaching, Total Organic Carbon, and Chlorine Residual in Drinking Water (opens in a new tab)

  9. Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system

    … oxygen concentration resulting from ozonation on copper corrosion in the water system. The piping system used in the pilot plant resembled a household piping system, and consisted of four loops of copper pipes. Silica was added to the finished water before entering the loops at three different …

    unlv Repository record for Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system (opens in a new tab) Download PDF for Assessing silica and dissolved oxygen effects on copper corrosion control in southern Nevada water treatment and supply system (opens in a new tab)

  10. Interactions Between Copper and Chlorine Disinfectants: Chlorine Decay, Chloramine Decay and Copper Pitting

    Interactions between copper and chlorine disinfectants were examined from the perspective of disinfectant decay and copper pitting corrosion. Sparingly soluble cupric hydroxide catalyzed the rapid decay of free chlorine, which in turn, led to production of less soluble and more crystalline phases …

    vt Repository record for Interactions Between Copper and Chlorine Disinfectants: Chlorine Decay, Chloramine Decay and Copper Pitting (opens in a new tab)

  11. The effect of early season soil temperatures on corn canopy development: A quantitative approach

    … using warm and cool water circulating through copper pipes buried next to the corn rows. The treatments consisted in maintaining the temperature of the soil surrounding the corn growing point 5$\sp\circ$C above and below ambient temperature. Plant stage, individual leaf area, and leaf …

    uiuc Repository record for The effect of early season soil temperatures on corn canopy development: A quantitative approach (opens in a new tab)

  12. Modelling and Measurements on a Condensing Counter-Flow Heat Exchanger

    … of 15 metres of a thermally coupled pair of copper pipes, one containing the R12 working fluid and the other water flowing in the opposite direction. This condenser was mounted horizontally and folded into 0.5 metre straight sections. Thermocouples were inserted in both pipes at one metre …

    aston Repository record for Modelling and Measurements on a Condensing Counter-Flow Heat Exchanger (opens in a new tab) Download PDF for Modelling and Measurements on a Condensing Counter-Flow Heat Exchanger (opens in a new tab)

  13. Effects of 2,4-Di-<i>Tert</i>-Butylphenol on Osteogenic and Myogenic Differentiation of Human Induced Pluripotent Stem Cells

    … is primarily used in polyethylene crosspolymer pipes, which are now used as a replacement for the traditional copper pipes for household water distribution. However, 2,4-DBP has been found to leach from these pipes into the water, enabling a mode of exposure to humans. 2,4-DBP has been detected …

    clemson Repository record for Effects of 2,4-Di-<i>Tert</i>-Butylphenol on Osteogenic and Myogenic Differentiation of Human Induced Pluripotent Stem Cells (opens in a new tab)

  14. Impact of an Epoxy Pipe Lining Material on Distribution System Water Quality

    Corrosion of iron and copper pipes can produce leaks and loss of efficiency in the water distribution system, elevate levels of contaminants at the tap, and cost billions of dollars annually in pipe replacement or rehabilitation. In situ pipe rehabilitation using cement mortar, polyurethane, and …

    vt Repository record for Impact of an Epoxy Pipe Lining Material on Distribution System Water Quality (opens in a new tab)

  15. Growth of Opportunistic Pathogens in Domestic Plumbing: Building Standards, System Operation, and Design

    … MI, corrosive Flint River water damaged iron pipes, releasing iron nutrients, consuming chlorine residual, and supporting high levels of L. pneumophila in large building systems. This likely triggered two unprecedented clusters of Legionnaire's disease. In pilot-scale systems, copper released …

    vt Repository record for Growth of Opportunistic Pathogens in Domestic Plumbing: Building Standards, System Operation, and Design (opens in a new tab)

  16. Impact of Polymeric Plumbing Materials on Drinking Water Quality and Aesthetics

    The use of polymer pipes is now very common in home plumbing and other parts of the drinking water distribution system. Many taste and odor complaints in drinking water are known to originate from contact of water with materials. The ability of polymer pipes used in home plumbing to affect drinking …

    vt Repository record for Impact of Polymeric Plumbing Materials on Drinking Water Quality and Aesthetics (opens in a new tab)

  17. Corrosion in New Construction:Elevated Copper, Effects of Orthophosphate Inhibitors, and Flux Initiated Microbial Growth

    … can actually be worse in PVC/plastic than in copper systems, if certain types of microbes such as nitrifiers proliferate and drop pH. Some of the problems initiated by construction practices can persist indefinitely, causing higher levels of lead and copper in water, or longer term, …

    vt Repository record for Corrosion in New Construction:Elevated Copper, Effects of Orthophosphate Inhibitors, and Flux Initiated Microbial Growth (opens in a new tab)

  18. Evaluation of the Impact of Membrane Change at a Membrane Softening Water Treatment Plant

    … has a tendency to leach metals from lead and copper pipes in the distribution networks. To prevent such problems, the permeate needs to be blended with partially treated raw water or to be chemically treated to re-mineralize and add alkalinity back into the water. In the last decade …

    usf Repository record for Evaluation of the Impact of Membrane Change at a Membrane Softening Water Treatment Plant (opens in a new tab)

  19. Investigating the Role of Water Quality on the Galvanic Corrosion of Lead in Hard Drinking Water with a Focus on NOM

    … waters. The test pieces consisted of lead and copper pipes with an external galvanic connection. This experiment involved 20 weeks of “dump and fill” events where the test pieces were manually emptied and then refilled with water of the same chemistry. The pH had a potentially significant …

    waterloo Repository record for Investigating the Role of Water Quality on the Galvanic Corrosion of Lead in Hard Drinking Water with a Focus on NOM (opens in a new tab)

  20. Flow Induced Failures of Copper Drinking Water Tube

    … velocities can contribute to rapid failures of copper premise plumbing systems. This is the first fundamental study to scientifically isolate mechanistic impacts from distinct flow induced failure mechanisms that include concentration cell corrosion, cavitation, particle/bubble impingement and …

    vt Repository record for Flow Induced Failures of Copper Drinking Water Tube (opens in a new tab)

Page 1 of 2