Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"corneal swelling"”

  1. Overnight Corneal Swelling and Deswelling with Silicone Hydrogel Lenses

    Purpose: To compare central corneal swelling (CS) after eight hours of sleep in eyes wearing 12 different silicone hydrogel (SiHy) contact lenses (CLs) and to model between-subject variability in CS and deswelling. Methods: 29 neophytes wore 12 SiHy lenses with a central transmissibility range of …

    waterloo Repository record for Overnight Corneal Swelling and Deswelling with Silicone Hydrogel Lenses (opens in a new tab)

  2. Corneal hydration and the accuracy of Goldmann tonometry.

    … of this thesis was to investigate the effect of corneal swelling on the accuracy of Goldmann tonometry estimates of intraocular pressure (IOP). In the first experiment, central corneal thickness (CCT, ultrasonic pachymetry), IOP (Goldmann tonometry) and corneal curvature (keratometry) was …

    unsw Repository record for Corneal hydration and the accuracy of Goldmann tonometry. (opens in a new tab)

  3. Changes in corneal thickness in keratoconic eyes with variation in scleral contact lens central clearance

    … lens wear, particularly for patients with corneal ectasia, such as keratoconus. This method of lens correction provides good visual acuity for these individuals and is often a clinically sought-after lens modality where others fail. The scleral lens vaults the ocular surface over a fluid …

    waterloo Repository record for Changes in corneal thickness in keratoconic eyes with variation in scleral contact lens central clearance (opens in a new tab)

  4. A clinical description of ocular response analyser parameters

    … instrument that measures parameters called corneal hysteresis (CH) and corneal resistance factor (CRF), which are believed to be corneal biomechanical responses. These variables have experienced increasing interest in ophthalmic practice. However, there is little experimental work …

    unsw Repository record for A clinical description of ocular response analyser parameters (opens in a new tab)

  5. Cloning and Sequencing of Bovine Na+/K= Atpase α-1 Sub-Unit

    … the α-1 sub-unit of Na+/K+-ATase gene in bovine corneal endothelium. The Na+/K+-ATase, also called the Na+ pump, is a crucial transmembrane protein. By transporting water and ions from and through the cornea into the aqueous humor, it is responsible for maintenance of structural integrity, …

    wku-diss Repository record for Cloning and Sequencing of Bovine Na+/K= Atpase α-1 Sub-Unit (opens in a new tab)

  6. Corneal Hydration and endothelial Morphology During and After Cryopreservation

    … a viable endothelium is important for successful corneal transplantation. The supply of human donor tissue is limited by rigid eye bank requirements and the short-term shortage of 48 hours at 4°C. A procedure of long-term storage by corneal preservation (Kaufman and Capella, J. Cryosurg. 1:125, …

    marquette Repository record for Corneal Hydration and endothelial Morphology During and After Cryopreservation (opens in a new tab)

  7. Comparative Clinical Performance of Scleral Lenses with Varying Limbal Clearance in a Keratoconic Population

    … discussed. METHODS For Chapter 3: based on the corneal sagittal depth at a chord of 15.0mm, participants were fitted with two sets of scleral lenses with the same central sagittal depth and varying limbal clearances (LC) which differed by 50µm. Lenses were worn in a randomly assigned order for a …

    waterloo Repository record for Comparative Clinical Performance of Scleral Lenses with Varying Limbal Clearance in a Keratoconic Population (opens in a new tab)

  8. In Vivo Imaging of Corneal Conditions using Optical Coherence Tomography

    … to image and quantify the effect of various corneal conditions, in terms of corneal, stromal and epithelial thickness, and light backscatter. To assess the changes caused by overnight orthokeratology (Corneal Refractive Therapy; CRT<sup>TM</sup>) lens wear, keratoconus and laser in-situ …

    waterloo Repository record for In Vivo Imaging of Corneal Conditions using Optical Coherence Tomography (opens in a new tab)

  9. Comparison of two contact lens fitting strategies for keratoconus

    … Lens (FDACL) concept is useful for fitting corneal RGP lenses with a variable optic zone diameter and to evaluate which soft contact lens power should be used for piggyback lens fitting in keratoconus. Finally, the relationship between RGP contact lens wear and anterior corneal surface …

    minho-thes Repository record for Comparison of two contact lens fitting strategies for keratoconus (opens in a new tab)

  10. Contact lens fitting characteristics and comfort with silicone hydrogel lenses

    … in a normal sample. The second was to compare corneal thickness measured with the Visante TM OCT to the Zeiss-Humphrey OCT II (model II, Carl Zeiss Meditec, Jena Germany) adapted for anterior segment imaging and to the Orbscan II TM (Bausch and Lomb, Rochester New York). Chapter 4: Conjunctival …

    waterloo Repository record for Contact lens fitting characteristics and comfort with silicone hydrogel lenses (opens in a new tab)