Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 14 of 14 for “"corneometer"”.
-
Beeinflussung der akuten Entzündung durch Gentianaviolett, Eosin und Unguentum polyenthylenglycoli
… Behandlung der Was-sergehalt der Hornschicht (Corneometer® CM 820), der Zustand der Hautbarriere (Tewameter® TM 210), sowie das Entzündungsausmaß (Periflux 2 Laser Doppler Flowmeter). <br>Die Auswertung erfolgte mit dem Wilcoxon-Test für Paardifferenzen. <br>Methylrosaniliniumchlorid NRF 11.69 …
-
Non-invasive methods of quantifying the composition of the plantar epidermis: The interpretation of data in health, ageing and disease.
… in which three commercially available devices (Corneometer® CM825, MoistureMeter D® and MoistureMeter SC™) are used to quantify plantar epidermal hydration alongside measures of skin hardness, elasticity, surface texture, and perceived skin health. Study 2: ‘An evaluation of the biochemical …
-
Bestimmung des Irritationspotentials von Dusch- und Badeölen auf normaler bis trockener Haut
… Messungen mit dem Tewameter, Mexameter und Corneometer durchgeführt. Die Ergebnisse wurden statistisch ausgewertet. Ergebnisse: Die Ergebnisse der vier Messvariablen bestätigen fast ausnahmslos, dass die Testsubstanzen A (Bedan®) und B (Balneum Hermal®) ein signifikant geringeres …
-
Über die exsikkierende und okkludierende Wirkung von Schüttelmixturen, Zinköl, Polyethylenglycolgel DAB und einer Polyethylenglycolpaste
… Prüfsubstanzen wurde durch kapazitive Messungen (Corneometer CM 820) und Conduktivitätsmessungen (Skicon 200) dargestellt. Unter den Bedingungen von Studie 1 und 2 ließ sich sowohl für die glycerinhaltige Schüttelmixtur DAC, als für auch beide Polyethylenglycolgele (mit oder ohne Zinkoxid) eine …
-
Obtenção de extratos da Opuntia fícus-indica L. Mill e suas aplicações em formulações cosméticas: avaliação in vivo do sensorial e da eficácia hidratante
… realizada por meio do método da capacitância (Corneometer®) e da avaliação da perda de água transepidermal - TEWL (Tewameter®). Observou-se que a formulação com 3% do EHG001 apresentou eficácia hidratante frente ao veículo e ao solvente extrator após 5 horas e as emulsões contendo 1 e 3% do …
-
Effect of dietary polyunsaturated fatty acid and related nutrients on plasma lipids, and skin and hair coat condition in canines
… 23 (Phase II) using a Tewameter[trademark] and Corneometer[trademark] respectively. Blood samples were collected on d 0, 5, 8, 16, 28, 56, and 84. Profiles of plasma phospholipid fatty acids were determined at each collection period. Serum zinc concentrations were analyzed on wk 12, 14, and 24. …
-
The influence of different types of barrier creams on skin barrier function
… probes all from Courage and Khazaka, Germany: a Corneometer measuring skin hydration and a pH-Meter measuring skin surface pH. The measurements were repeated on each of the four sampling areas (forearm, wrist, back of hand and palm) with a reasonable time interval between each measurement. After …
-
A critical appraisal of the efficacy of dietary supplements on skin ageing
… or equipment are skin replica analysis, corneometer and cutometer. A meta-analysis was not possible since the included studies employed a range of dietary supplements and employed a diversity of different methodologies. To our knowledge, this is the first review that has classified and …
-
Investigation of skin physiological parameters in term neonates and evaluation of the influence of bathing on skin barrier function in newborns during the first four weeks of life
… MPA® connected with four probes: tewameter, corneometer, pH-meter and sebumeter. The statistical analysis of the results obtained in both groups showed a significant increase in SCH and sebum as well as a significant decrease in pH values during the first four weeks of life. These findings …
-
Nanosuspensions and nanostructured lipid carriers for dermal application
… the skin could be shown by the reduction of the Corneometer values. No significant difference in the release of coenzyme Q10 from NLC and o/w emulsion was found whereas the release of coenzyme Q10 from liquid paraffin was significant lower in vitro. The coenzyme Q10 release followed zero-order …
-
E-textile sensor for monitoring and evaluation of atopic dermatitis in skin
… 5 pF. The sensor correlated significantly with Corneometer® measurements, a gold-standard for skin hydration testing (r = 0.595, p < 0.05). Furthermore, the e-textile IDC sensor demonstrated tighter clustering of the readings compared to other methods of assessment, indicating better variability …
-
Short-term effects of selected barrier creams on skin barrier function
… Ltd., Kuopio, Finland), skin hydration using a Corneometer® CM 825 and skin surface pH using a pH meter probe (Courage and Khazaka Electronic Kӧln, Germany). A micro-pipette was used to drip a standard volume of 20 μl of ultrapure water on the skin surface before the researcher placed the pH …
-
Transdermal penetration enhancement and clinical efficacy of Aloe marlothii and Aloe ferox compared to Aloe vera
… of the aloe materials were determined with the Corneometer® CM 825 and Visioscan® VC 98 during the short term study (single application) and longer term study (multiple applications). In addition, as an indirect measurement of skin hydration, the Cutometer® dual MPA 580 was used to measure skin …
-
Characteristics of ageing skin
Introduction: Skin cancer, especially in elderly patients, is one of the most fatal skin diseases. However, the prevalence in institutional long-term care (ILTC) facilities is mostly unknown. Transepidermal Water Loss (TEWL) is considered as an important parameter in skin research, which is …