Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"coronary stent"”.

  1. Bioactive surfaces for improved coronary stent performance

    Drug eluting stents (DES) are widely used to treat coronary heart disease. Although current DES generally perform well, restenosis and delayed endothelium healing still remains an issue following stent implantations. Research efforts are now focused on the development of stent coatings that address …

    strathclyde Repository record for Bioactive surfaces for improved coronary stent performance (opens in a new tab)

  2. Experimentelle Untersuchungen am porzinen „over-sized coronary stent“-

    … investigations at the porcine over-sized coronary stent-model for in-stent-restenosis rate after implantation of uncoated niob-zirkonium stents and niob-zirkonium stents coated with iridiumoxide. Background: The treatment of atherosclerotic stenosis in coronary artery disease with balloon …

    lmu-germany Repository record for Experimentelle Untersuchungen am porzinen „over-sized coronary stent“- (opens in a new tab)

  3. Production of Polyhydroxyalkanoates and their application for coronary stent development

    Development of coronary artery stents have revolutionised the treatment of coronary artery disease. However, the currently available stents have several limitations and side effects, which still need to be addressed. Within this group of biomaterials Polyhydroxyalkanoates (PHAs), which are …

    westminster Repository record for Production of Polyhydroxyalkanoates and their application for coronary stent development (opens in a new tab) Download PDF for Production of Polyhydroxyalkanoates and their application for coronary stent development (opens in a new tab)

  4. Novel Representation and Concept-Based Optimisation Techniques for Coronary Stent Designs

    Coronary stents are extensively used medical devices for treating coronary artery disease, a leading cause of morbidity worldwide. Stent designs play a key role in the success of coronary stenting, with various designs available for clinical use, including Independent Ring (IR) and Helical Stent …

    unsw Repository record for Novel Representation and Concept-Based Optimisation Techniques for Coronary Stent Designs (opens in a new tab)

  5. The safety and efficacy of novel dual function coronary stent in porcine model of myocardial infarction

    … to evaluate the effectiveness of a dual function coronary stent in both inhibiting In Stent Restenosis (ISR) and salvaging the injured myocardium following acute myocardial infarction in pigs. Background: For more than a decade, drug eluting stents have written a successful chapter in coronary …

    cork Repository record for The safety and efficacy of novel dual function coronary stent in porcine model of myocardial infarction (opens in a new tab) Embargoed until 9999-12-31

  6. Development of In Vitro Tissue Engineered Blood Vessel Mimics in Complex Geometries for Coronary Stent Testing

    Coronary heart disease is the leading cause of death in the United States and occurs when plaque occludes coronary arteries. Coronary stents, which may be used to treat coronary occlusions, are small metal tubes that are implanted in coronary arteries to restore blood flow. After stent …

    calpoly Repository record for Development of In Vitro Tissue Engineered Blood Vessel Mimics in Complex Geometries for Coronary Stent Testing (opens in a new tab)

  7. Vergleich von Nominal- versus Hochdruckballoninflatation für optimale Koronarstent-Implantation durch IVUS und QCA mit EXPRESS™ Coronary Stent System

    … of Cardiology Expert Consensus Document on Coronary Artery Stents, high pressure post-dilatation strategy still encountered several controversies due to its deleterious effects on the vascular wall and its distortion of the stent geometry leading to a predilection to restenosis. Researches …

    lmu-germany Repository record for Vergleich von Nominal- versus Hochdruckballoninflatation für optimale Koronarstent-Implantation durch IVUS und QCA mit EXPRESS™ Coronary Stent System (opens in a new tab)

  8. A Study of Carbon Infiltrated Carbon Nanotubes Fabricated on Convex Cylindrical Substrates for the Creation of a Coronary Stent

    … rods for the purposes of creating a CI-CNT coronary stent. It is a continuation of the work begun by Jones [1] and Skousen [2] whose work included the creation of a feasible CI-CNT coronary stent on a planar surface. The current research was performed in two parts: 1) growth on the whole …

    byu Repository record for A Study of Carbon Infiltrated Carbon Nanotubes Fabricated on Convex Cylindrical Substrates for the Creation of a Coronary Stent (opens in a new tab) Download PDF for A Study of Carbon Infiltrated Carbon Nanotubes Fabricated on Convex Cylindrical Substrates for the Creation of a Coronary Stent (opens in a new tab)

  9. Design Exploration and Analysis of Carbon-Infiltrated Carbon Nanotube Vascular Stents

    … this research was to design, develop, and test coronary stent designs composed of carbon-infiltrated carbon nanotubes (CI-CNTs). Coronary stents currently have two major complications: restenosis and thrombosis. CI-CNT stents have potential to address both of these issues, and therefore may …

    byu Repository record for Design Exploration and Analysis of Carbon-Infiltrated Carbon Nanotube Vascular Stents (opens in a new tab) Download PDF for Design Exploration and Analysis of Carbon-Infiltrated Carbon Nanotube Vascular Stents (opens in a new tab)

  10. IVOCT imaging artifacts of coronary stents

    Coronary stent placement is a routine treatment of coronary artery disease, the leading cause of death worldwide. Intravascular Optical Coherence Tomography (IVOCT) is a superior imaging assessment technique in coronary stenting. To characterize IVOCT artifacts, phantom blood vessels were …

    texas Repository record for IVOCT imaging artifacts of coronary stents (opens in a new tab)

  11. A combined experimental and computational framework to optimise processing and design of poly(L-lactic acid) bioresorbable stents

    Coronary heart disease, caused by inflammatory hardening and narrowing of arteries (atherosclerosis) is the largest cause of death in the world. Coronary stents, used to treat atherosclerosis, are typically manufactured from high strength metallic alloys; however such devices remain in the body …

    qu-belfast Repository record for A combined experimental and computational framework to optimise processing and design of poly(L-lactic acid) bioresorbable stents (opens in a new tab) Download PDF for A combined experimental and computational framework to optimise processing and design of poly(L-lactic acid) bioresorbable stents (opens in a new tab)

  12. Εκτίμηση in vivo της αποτελεσματικότητας ενδοαγγειακής πρόθεσης με δυνατότητα απελευθέρωσης ρετινοϊκού οξέος σε πειραματικά μοντέλα

    … the safety and efficacy of an innovative coronary stent coated with retinoic acid and a biodegradable polymer for the treatment of cardiovascular disease.Methods: A total of 60 stents were implanted in the iliac arteries of 30 rabbits. The stents consisted of two different types of …

    greece Repository record for Εκτίμηση in vivo της αποτελεσματικότητας ενδοαγγειακής πρόθεσης με δυνατότητα απελευθέρωσης ρετινοϊκού οξέος σε πειραματικά μοντέλα (opens in a new tab)

  13. Towards non-invasive characterisation of re-endothelialisation and restenosis following coronary stenting : an in vitro investigation using impedance spectroscopy

    Following the permanent implantation of a coronary stent, optimal arterial wall healing is characterised by re-endothelialisation, the regrowth of a functional Endothelial Cell (EC) monolayer over the exposed stent surface. However incomplete re-endothelialisation, increases the risk of stent …

    strathclyde Repository record for Towards non-invasive characterisation of re-endothelialisation and restenosis following coronary stenting : an in vitro investigation using impedance spectroscopy (opens in a new tab)

  14. Design and Optimization of a Blood Vessel Mimic Bioreactor System for the Evaluation of Intravascular Devices in Simple and Complex Vessel Geometries

    Coronary artery disease affects millions of people and the ability to detect and treat the disease is advancing at a rapid rate. As a result, the development of intravascular technologies is the focus of many medical device manufacturers. Specifically, coronary stent implantation is being performed …

    calpoly Repository record for Design and Optimization of a Blood Vessel Mimic Bioreactor System for the Evaluation of Intravascular Devices in Simple and Complex Vessel Geometries (opens in a new tab)

  15. Η επίδραση των εμποτισμένων με διάφορες φαρμακευτικές ουσίες μεταλλικών ενδοπροθέσεων στο τοίχωμα των νεφρικών αρτηριών

    Introduction Recent reports concerning coronary, carotid, and femoral vasculature have proposed the use of drug-eluting metal stents (MS) to improve clinical and angiographic outcomes. Based on these reports, we used paclitaxel-eluting MS within an animal renal artery lumen and compared the results …

    greece Repository record for Η επίδραση των εμποτισμένων με διάφορες φαρμακευτικές ουσίες μεταλλικών ενδοπροθέσεων στο τοίχωμα των νεφρικών αρτηριών (opens in a new tab)

  16. Non-invasive impedance monitoring of vascular cell growth on coronary stents

    Coronary heart disease is the leading cause of death in developed countries. Implantation of a stent, by percutaneous coronary intervention, has emerged as a safe and widely used procedure to address this problem. However, a number of limitations remain with this technique, including potentially …

    strathclyde Repository record for Non-invasive impedance monitoring of vascular cell growth on coronary stents (opens in a new tab)

  17. MicroCT of Coronary Stents: Staining Techniques for 3-D Pathological Analysis

    In the area of translational research, stent developers consult pathologists to obtain the best and most complete amount of data from implanted test devices in the most efficient manner. Through the use of micron-scale computed tomography along with post-fixation staining techniques in this study, …

    tamu Repository record for MicroCT of Coronary Stents: Staining Techniques for 3-D Pathological Analysis (opens in a new tab)

  18. On the design of low-power low-voltage circuits for smart stents

    … in general, and with an emphasis on “Smart Stent” applications. In the context of smart stents, the goal is to collect and transmit sensory data from a stent, for example, the one that is implanted inside an artery or inside the ureter, for clinical diagnosis. The power for the electronic …

    ubc Repository record for On the design of low-power low-voltage circuits for smart stents (opens in a new tab) Download PDF for On the design of low-power low-voltage circuits for smart stents (opens in a new tab)