Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 49 for “"coulometry"”.

  1. Real-time computer optimized scanning potential coulometry for multi-component trace analysis

    … real-time computer controlled scanning potential coulometry for multi-component trace analysis is described. The sensitivity limit was determined to be 10^-8 F for electrochemically reversible constituents. The sensitivity limit could be extended if measures were taken to compensate for the …

    byu Repository record for Real-time computer optimized scanning potential coulometry for multi-component trace analysis (opens in a new tab) Download PDF for Real-time computer optimized scanning potential coulometry for multi-component trace analysis (opens in a new tab)

  2. Nonaqueous solvent systems, instrumentation, and high precision assay in constant-current coulometry

    … A charge buret for use in constant-current coulometry is described. It provides manual and automatic control of the current flow and measures the time of current flow to within 0.005%. NBS SRM 136c, potassium dichromate, was assayed by high precision coulometric titration. A differential …

    byu Repository record for Nonaqueous solvent systems, instrumentation, and high precision assay in constant-current coulometry (opens in a new tab)

  3. The Precise Determination of Equilibrium Constants by Constant Current Coulometry. The Copper - Cuprous - Cupric System

    Made available in DSpace on 2014-12-05T19:37:54Z (GMT). No. of bitstreams: 1 6200651.pdf: 3523975 bytes, checksum: 56f374c0144be3a420f64efc560992e0 (MD5) Previous issue date: 1961

    uiuc Repository record for The Precise Determination of Equilibrium Constants by Constant Current Coulometry. The Copper - Cuprous - Cupric System (opens in a new tab)

  4. An electrochemical instrument for the analysis of heavy metals in water via anodic stripping coulometry for applications in remote sensing.

    … is based on exhaustive anodic stripping coulometry in a fixed-volume cell and the target analytes are As(III) and Pb(II). Herein, the electrochemical device was redesigned to improve the detection limits for As(III) using double potential step-anodic stripping coulometry (DPS-ASC) to meet …

    louisville Repository record for An electrochemical instrument for the analysis of heavy metals in water via anodic stripping coulometry for applications in remote sensing. (opens in a new tab)

  5. Optimization of Electrode Configurations for Calibration-Free, Remote Sensing of Heavy Metals in Water Using Double-Potenital Step Anodic Coulometry

    Many areas around the world are known and predicted to suffer from arsenic-contaminated drinking water resulting in elevated medical issues. Current arsenic detection techniques require that a sample be taken at the site, carried to the lab, and then tested by a skilled technician, which is not …

    eku Repository record for Optimization of Electrode Configurations for Calibration-Free, Remote Sensing of Heavy Metals in Water Using Double-Potenital Step Anodic Coulometry (opens in a new tab)

  6. Electrochemical reactions of polypyridyl complexes of iron, cobalt & nickel

    … processes was obtained using constant potential coulometry in which milligram quantities of the metal (II) complexes were electrolysed in acetonitrile solutions at potentials in the region of the peak potentials of the corresponding cyclic voltammograms. The preliminary studies in voltammetry and …

    city-london Download PDF for Electrochemical reactions of polypyridyl complexes of iron, cobalt & nickel (opens in a new tab)

  7. Electrochemical behavior of rhodium (I) alkylisocyanides in various solvents and supporting electrolyte systems

    … have been examined using cyclic voltammetry, coulometry and bulk electrolysis. The effect of coordinating and non-coordinating solvents and supporting electrolytes on the oxidation of these complexes has been investigated. A correlation of the ease of oxidation and the bulkiness of the …

    ut-knoxville Repository record for Electrochemical behavior of rhodium (I) alkylisocyanides in various solvents and supporting electrolyte systems (opens in a new tab)

  8. A palladium membrane reactor for organic transformations

    … has minimal electron density. I demonstrate that coulometry can be an accurate technique to quantify hydrogen absorption when an electrochemical flow cell is used. The flow cell improves the selectivity of coulometry and enables quantification of absorbed hydrogen for a number of different …

    ubc Repository record for A palladium membrane reactor for organic transformations (opens in a new tab) Download PDF for A palladium membrane reactor for organic transformations (opens in a new tab)

  9. Determination of nitosoamines by DP polarography and investigation of kinetics of electroreduction of N–Nitrosodimethylamine by voltammetric techniques

    … of NDMA was studied using controlled potential coulometry, linear scan voltammetry (LSV) and cyclic voltammetry (CV). Controlled potential coulometry was first used to determine the number of electrons transferred (n) in the reduction reaction. Two moles of electrons were found to be required …

    nwu-za Repository record for Determination of nitosoamines by DP polarography and investigation of kinetics of electroreduction of N–Nitrosodimethylamine by voltammetric techniques (opens in a new tab)

  10. Application of microfabrication in electrochemical sensing.

    … sustainable over weeks. Sensors for exhaustive coulometry were designed, fabricated and evaluated. Microchips contained thin-film gold working and Ag/AgCI pseudo-reference electrodes. A custom flow cell containing a counter electrode chamber was constructed to integrate the sensor and to create …

    louisville Repository record for Application of microfabrication in electrochemical sensing. (opens in a new tab)

  11. The optical properties of oxide films on copper and copper alloys

    … the oxide was confirmed by x-ray diffraction and coulometry. Spectral measurements covering the wavelength range 350 - 750 nm were made using an automatic, self-nulling ellipsometer. From this data the optical constants and thickness of the oxide films were computed and compared to those of the …

    london-metro Download PDF for The optical properties of oxide films on copper and copper alloys (opens in a new tab)

  12. Preparation and Application of Conducting Polymer-Carbon Nanotube Composite.

    … reaction. Voltammetry, bulk electrolysis with coulometry, AC impedance, and EQCM techniques have been used to elucidate the preparation, ion transport, and intermolecular interaction processes within these composites.

    etsu Repository record for Preparation and Application of Conducting Polymer-Carbon Nanotube Composite. (opens in a new tab) Download PDF for Preparation and Application of Conducting Polymer-Carbon Nanotube Composite. (opens in a new tab)

  13. Electrochemical leaching of gold-bearing arsenopyrite in alkaline cyanide solutions

    … linear sweep voltammetry and constant potential coulometry were used to determine the electrochemical response of arsenopyrite in the absence and in the presence of cyanide and to determine its dissolution chemistry. Surface oxidation of arsenopyrite is proposed to proceed by a two-step reaction …

    arizona-thes Repository record for Electrochemical leaching of gold-bearing arsenopyrite in alkaline cyanide solutions (opens in a new tab)

  14. Electrochemical studies of tantalum and niobium in molten chloroaluminates

    … pulse polarography, controlled-potential coulometry, and constant current electrolysis. The electrochemical reduction mechanisms, redox potentials, and stability of the reduction products were examined as a function of temperature, melt composition, Ta(v) concentration, and time of …

    utk-theses Repository record for Electrochemical studies of tantalum and niobium in molten chloroaluminates (opens in a new tab)

  15. Spectroelectrochemical investigations in molten salt and aqueous media

    … spectroelectrochemical techniques and thin-layer coulometry at optically transparent electrodes. The reduction of the manganese oxyanions in alkaline solutions has been found to consist of simple reversible one electron transfers when carried out in solutions in which the reduction product is …

    utk-theses Repository record for Spectroelectrochemical investigations in molten salt and aqueous media (opens in a new tab)

  16. The kinetics of the oxidation of alcohols with electrogenerated halogens

    … in strongly acidic solutions. Controlled-current coulometry was used to generate the halogens from aqueous solutions of the halide salts. For each system investigated, the pseudo first-order rate constants were determined by the current decay method. Second-order rate constants were evaluated …

    vt Repository record for The kinetics of the oxidation of alcohols with electrogenerated halogens (opens in a new tab)

  17. Electroanalysis of single nanoparticles via particle-electrode collision processes

    … of silver NPs (AgNPs) using anodic particle coulometry (APC). This theme is then extended to gold and nickel NPs, aggregation studies and the measurement of sticking coecients. Furthermore, the determination of nanoparticle concentration is realised by measurement of the flux to …

    oxford Repository record for Electroanalysis of single nanoparticles via particle-electrode collision processes (opens in a new tab)

Page 1 of 3