Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 1059 for “"counters"”.

  1. Gas scintillation counters

    Construction details of a 5" diameter 1.7 litre gas scintillation counter are given. The behaviour of the counter when containing He⁴ gas and a mixture of He⁴ and 10% Xe at various total pressures has been investigated. Two 5" photomultiplier tubes and a variety of different gas purifiers were …

    ubc Repository record for Gas scintillation counters (opens in a new tab) Download PDF for Gas scintillation counters (opens in a new tab)

  2. Multiwire proportional counters

    The aim of this work is twofold: first, to develop a multilayered multiwire proportional chamber which would be useful as a position-sensitive detector in tracking the path of a beam of elementary particles and identifying the particles by their energies; and second, to measure the operating …

    ubc Repository record for Multiwire proportional counters (opens in a new tab) Download PDF for Multiwire proportional counters (opens in a new tab)

  3. Reversible relay counters

    This work is concerned with the design of counters built on electromagnetic relays, having two input switches, and indicating the difference between the numbers of times the input switches have been operated, modulo some number, the scale of the counter. The methods used are those for the design of …

    city-london Download PDF for Reversible relay counters (opens in a new tab)

  4. Profiling Concurrent Programs Using Hardware Counters

    … has at its disposal is a set of hardware counters, which are specialized CPU registers that count the occurrences of hardware events as a program executes. Hardware-event counts provide extremely precise insight into the execution behaviour of a program, and can be used to pinpoint …

    waterloo Repository record for Profiling Concurrent Programs Using Hardware Counters (opens in a new tab)

  5. The neutron sensitivities of Geiger-Müller counters

    … of the neutron sensitivities of such counters have not always been in good agreement. In the present work the neutron sensitivities of two types of G-M counters, viz. ZP1320 and ZP1300 have been measured at neutron energies between 0.72 and 7.42 MeV. An absolute measurement of the …

    cape-town Repository record for The neutron sensitivities of Geiger-Müller counters (opens in a new tab)

  6. Automated Classification and Verification of Performance Counters

    <p>Efficient execution of scientific applications on high-performance computing (HPC) systems depends heavily on effective performance analysis. Performance analysis refers to the process of evaluating how well an application performs on an HPC system, including its interaction with underlying …

    utk-theses Repository record for Automated Classification and Verification of Performance Counters (opens in a new tab)

  7. Resolution and line shape in scintillation counters

    … the pulse height resolution of Scintillation Counters. A statistical model is developed from which an analytic expression for the ideal line shape is obtained. Excellent agreement is found with observations using an artificial light pulser. An attempt to understand the noise spectra, …

    ubc Repository record for Resolution and line shape in scintillation counters (opens in a new tab) Download PDF for Resolution and line shape in scintillation counters (opens in a new tab)

  8. A study of parallel plate proportional counters

    Current interest in a counter with fast response and thin transmission has led to the construction and study of a parallel plate proportional counter (PPPC). The PPPC was found to be essentially 100% efficient in the detection of 3 MeV protons. Gas gains near 104 were obtained in the pressure range …

    rice Repository record for A study of parallel plate proportional counters (opens in a new tab)

  9. A Hot-Wire Anemometer for Particle Counters

    Portable real-time air quality monitoring is becoming a reality. While the data quality of these devices may be questionable, they have shown to be promising. One such device is the optical particle counter. The particle counter functions by having laminar airflow with constant velocity traverse …

    boise Repository record for A Hot-Wire Anemometer for Particle Counters (opens in a new tab)

  10. Assessing malware detection using hardware performance counters

    … also propose the use of Hardware Performance Counters (HPCs). HPCs are counters embedded in modern computing architectures that count the occurrence of architectural events, such as cache hits, clock cycles, and integer instructions. Malware detectors that leverage HPCs create a profile of an …

    bu Repository record for Assessing malware detection using hardware performance counters (opens in a new tab)

  11. EMACS: efficient CXL-based memory access counters

    Submission published under a 24 month embargo labeled 'U of I Access', the embargo will last until 2026-05-01

    uiuc Repository record for EMACS: efficient CXL-based memory access counters (opens in a new tab)

  12. Studies of orbital electron capture using proportional counters

    … appreciable part of the discussion on gas source counters is based on the writer's own experience. The next two chapters relate to the development of new proportional counter techniques, made with the aim of overcoming some of the limitations to the use of gas sources. An investigation into the …

    glasgow Repository record for Studies of orbital electron capture using proportional counters (opens in a new tab) Download PDF for Studies of orbital electron capture using proportional counters (opens in a new tab)

Page 1 of 53