Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"counting steps"”.

  1. A data acquisition system that uses signal scavenging to detect activity on floor pads

    … phone call or message text to caregivers when steps on the pad occur. We used microcontroller PIC18F4455 to read the signals from the four sensors on the pad, and process the data. This chip is small, less power consuming, and easy to set up and use. To test the design entirely, we started our …

    missouri Repository record for A data acquisition system that uses signal scavenging to detect activity on floor pads (opens in a new tab)

  2. A Comparison of Commonly Used Accelerometer Based Activity Monitors in Controlled and Free-Living Environment

    … BMI or tilt angle. In the second experiment, the steps recorded by the devices were compared to actual steps. Speed had the greatest influence on the accuracy these devices. At 40 m/min, the ActiGraph was the least accurate device for normal weight (38%), overweight (46%) and obese (48%) …

    utk-theses Repository record for A Comparison of Commonly Used Accelerometer Based Activity Monitors in Controlled and Free-Living Environment (opens in a new tab)

  3. Validation of Measures by the Lifecorder EX Activity Monitor

    … monitor in calculating resting metabolic rate, counting steps taken at a variety of speeds, reporting energy expenditure across a range of intensities, and categorizing exercise intensity in descriptive units as light (1-3), moderate (4-6), and vigorous (7-9). Ten male (24.6 ± 5.3 years) and ten …

    ut-knoxville Repository record for Validation of Measures by the Lifecorder EX Activity Monitor (opens in a new tab)

  4. Posture and sports performance

    … running performance by measuring time and counting steps. We observed no change in running time but a significant change (F(1,8)=5.7, p=0.04) in step count, but only for participants who could run 3.2-kilometers (2-miles) under 14 minutes. If a person is able to run 3.2-kilometers under 14 …

    alabama Repository record for Posture and sports performance (opens in a new tab)

  5. Influence of perivascular tumor infiltrating leukocytes on survival after resection of early hepatocellular carcinoma

    … This for example can be achieved by standardized counting of tumor‐infiltrating leukocytes. Independent from the type and the number of tumor‐infiltrating leukocytes, the location needs to be considered when predicting the outcome. HCC has a high degree of angiogenesis, and the surface area of …

    lmu-germany Repository record for Influence of perivascular tumor infiltrating leukocytes on survival after resection of early hepatocellular carcinoma (opens in a new tab)

  6. Sporttester s rozhraním Bluetooth LE

    Tato diplomová práce se zabývá návrhem sporttesteru, což je zařízení schopné počítat kadenci uběhnutých kroků a kontrolovat síly nárazů nohy na zem při běhání. Působení dlouhodobých silných nárazů při běhání může způsobit i vážné únavové zlomeniny kyčle, lýtkové kosti či v oblasti chodidla. …

    brno-tech Repository record for Sporttester s rozhraním Bluetooth LE (opens in a new tab)

  7. Accuracy of Pedometers and their use in a 10,000 Steps Per Day Intervention Study

    … the efficacy and feasibility of the 10,000 steps per day exercise prescription in sedentary, overweight men vs. women. The specific aims were to 1) assess the accuracy of 10 electronic pedometers over the course of a 400-m walk; 2) compare the step values of multiple brands of pedometers …

    utk-theses Repository record for Accuracy of Pedometers and their use in a 10,000 Steps Per Day Intervention Study (opens in a new tab)

  8. Proteins of the sympathetic nervous system

    … which was estimated by scintillation-counting. Since published details of the overall reliability of the method were meagre, some emphasis was placed on the evaluation of the possible sources of error in each of the stages in the analysis leading to the construction of the …

    oxford Repository record for Proteins of the sympathetic nervous system (opens in a new tab)