Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"couplant"”.
-
Through-metal ultrasonic transmission focusing on thermal effects and couplant material selection
… nature of these multi-stage systems, a couplant (gasket) material is key for ensuring good transmission. A range of couplant materials are tested for optimizing power transmission efficiency in first a semi-detachable UPT stage, and in a completely detachable “wand” UPT stage, where …
-
Evaluation of Ultrasonic Velocity Tests to Characterize Extraterrestrial Rock Masses
… surface roughness, and (4) utility of a gel couplant. Laboratory tests were then performed to assess the influence of these parameters in simulated space conditions, using concrete beams to simulate large sample sizes, and ground limestone to simulate regolith cover. The ensuing data analysis …
-
Enhancing Image Repeatability with Ultrasonic Array
… array element variability, and couplant wave velocity variability. A number of approaches are proposed in this thesis for determining the variations between<br/>measurements, including a cross-correlation method and a time-of-flight method. The<br/>principle of determining the …
-
Etude en temps réel du processus d'extraction de la tagitinine C en fonction des caractéristiques physico-chimiques du CO2 supercritique à l'aide de fibres optiques couplant un spectrophotomètre IRTF à un extracteur à fluide supercritique
L’extraction par fluide supercritique fait partie des nouvelles techniques de préparation d’échantillons solides qui ont émergé au cours de ces dernières années. Elle constitue une alternative intéressante aux techniques classiques d’extraction liquide-solide car le pouvoir solvant du fluide …
-
Ultrasonic Thickness Inspection of Steel Structures Using Magnetic Climbing Robots: Design, Deployment, and Field Validation
… thickness (UT) gauge deployment mechanism and a couplant dispensing system to facilitate in situ thickness measurement and structural health assessment. In contrast to traversability- centric studies, this work prioritizes the practical execution of condition assessment using UT measurements. …
-
Vibration modeling for vibrothermography
… coupling. We show that using compliant couplant and isolators at the contact points on specimen eliminates the effect of mounting and transducer characteristics on specimen resonances and makes the specimen vibration more repeatable. In addition, we show that isolators act as absorptive …
-
The development of fibre-optic acoustic emission sensors for structural health monitoring
… with the use of an appropriate ultrasonic couplant due to the high frequency signals emanating from an AE event (up to 1 MHz). The couplant is crucial to permit an efficient transfer of elastic waves between damage source and sensor. Piezo-electric sensors tend to be relatively bulky, so …
-
The Effect of Coupling Media on the Pulse Velocity of Concrete
… coupling effect was evaluated in terms of the couplant used, compressive strength, aggregate content and maximum size of coarse aggregate. Analysis of variances (ANOVA) was performed to determine if there are statistically significant differences between the measurements recorded using a …
-
TRANSPARENT CERAMICS & THEIR COMPOSITE SYSTEMS FOR PROTECTIVE WINDOW APPLICATIONS
… the developed bond evaluated also as an acoustic couplant for the system.
-
ULTRASONIC SIMULATION AND MEASUREMENTS WITH CUT-OFF FREQUENCY EXTRACTIONS
… and associated electronics, as well as the couplant to a structure, from experimental data is presented. The investigation reveals that it is unnecessary for the instrumentation to have an ideal frequency response function for a transducer because imperfect measurement behaviour can be …
-
Autonomous NDT – Mitigating Misalignment Effect of Inductively Coupled Ultrasonic Transducer Systems
… it is confirmed that <br/>varying adhesive couplant thicknesses lead to the change of correction curve between sensors. Adhesive <br/>couplant thickness cannot be easily controlled in practice, hence a new mitigation method is required. <br/>Finally, a geometric coil optimisation approach is …
-
Ultrasound field measurement and modelling for non-destructive testing
… piezoelectric transducer (also called a probe), couplant has to be applied between the test material and the probe allowing for ultrasonic waves generated in the probe by an active piezoelectric crystal to propagate into the testing material. The couplant can be water, mineral oil, or gel, …
-
'Variational' optimization in quantum field theory
… agreement between theory and experiment. The couplant freezes to a zero-energy value of $\alpha\sb{s}/\pi = 0.26,$ which is in remarkable concordance with values obtained phenomenologically.
-
Étude et caractérisation des solutions acoustiques pour un rotor caréné d’hélicoptère sous excitations réalistes
… sont traitées par une procédure itérative couplant les vitesses locales et les impédances effectives, assurant ainsi la cohérence du calcul en régime non-linéaire. Le code ainsi développé constitue un outil de prédiction et de conception efficace pour l’analyse et l’optimisation de …
-
Non-destructive evaluation of residual stress using phased array ultrasonics
… the acoustoelastic response, and quantify couplant gel-thickness effects. Uncontrolled coupling variation produced practically significant apparent stress errors, while adjacent-receiver subtraction and multi-path processing reduced the compensated mean gel-induced ToF error to 0.27 ns, …
-
Évaluation du potentiel de recharge aménagée des aquifères par récupération des eaux pluviales en Montérégie, Québec : sélection de sites et modélisations préliminaires
… préliminaires de faisabilité d’un système couplant la récupération des eaux de pluie (RWH, Rain water harvesting) et la recharge aménagée des aquifères (MAR, Managed Aquifer Recharge) dans un contexte agricole québécois, avec une application à la Montérégie. La démarche repose d’abord sur …
-
Méthode automatique de détermination des paramètres d'inspection ultrasonore pour la reconstruction TFM
… expérimentales et notamment à la couche de couplant entre les différentes pièces. Par ailleurs, son temps de calcul ne permet pas une optimisation en temps réel. La seconde méthode, basée sur un réseau de neurones convolutif, offre de meilleures performances sur des données réelles, avec une …
-
An evaluation of 1-3 connectivity composite transducers for air-coupled ultrasonic applications
… automated conditions, maintaining a consistent couplant layer can constitute a problem and is manifest in slower scanning rates. To improve scanning speed the ultrasound should ideally propagate across an intermediate airgap. This possibility has been inhibited by the lack of a suitable …
-
An air-coupled ultrasonic array scanning system for rapid through transmission NDT
… proposed approach is the removal of the water couplant, enabling a receiver array to be employed, and thus scan large areas more quickly. Flexibility would also be increased with this technique due to a capability to scan moisture sensitive parts. In order to achieve this, however, the …
-
Inspection of Historic Steel Bridges Using Ultrasonic Phased Array
… remove the PMMA case out of the pin to re-apply couplant for inspections. Finally, a modified angled wedge could also be applied within the PMMA case to search for different angled cracking.
Page 1 of 3