Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"coupling angle"”.

  1. Theory, Design, and Fabrication of Diffractive Grating Coupler for Slab Waveguide

    … of the grating coupler based on the desired coupling angle. The second part of the design process is to choose the geometry of the grating that gives maximum coupling efficiency based on rigorous analyses. The diffraction gratings are fabricated by recording the interference between two waves …

    byu Repository record for Theory, Design, and Fabrication of Diffractive Grating Coupler for Slab Waveguide (opens in a new tab)

  2. Kinematic Analysis of Trunk Coordination Throughout the Rowing Stroke Sequence

    … variability in lumbar-pelvis and thoracic-lumbar couplings during the rowing stroke. Rowers exhibited greater lumbar-pelvis coupling angle variability during the recovery-drive transition of the stroke sequence with increasing intensities, which may be necessary as the rower prepares for the added …

    ut-knoxville Repository record for Kinematic Analysis of Trunk Coordination Throughout the Rowing Stroke Sequence (opens in a new tab)

  3. Assessment of Coordination and Proprioception in Youth With Autism Spectrum Disorder

    … span of at least four days. To analyze the data, angle-angle plots were constructed for the left upper-arm and right thigh, and right shank-foot. Vector coding was used to obtain coupling angle and coupling angle variability information. No significant differences existed in coordination patterns …

    odu Repository record for Assessment of Coordination and Proprioception in Youth With Autism Spectrum Disorder (opens in a new tab)

  4. Quantifying Joint Coordination Variability in Anterior Cruciate Ligament-Reconstructed Individuals During Walking

    … A vector coding technique was used to calculate coupling angles for six joint couplings involving the hip, knee, and ankle across four periods within the stance phase. Joint coordination variability was defined as the standard deviation of the coupling angle between trials within a subject, and …

    tenn-hsc Repository record for Quantifying Joint Coordination Variability in Anterior Cruciate Ligament-Reconstructed Individuals During Walking (opens in a new tab)

  5. THEORY AND FABRICATION OF SUB-MICRON GRATINGS ON NONLINEAR OPTICAL WAVEGUIDES.

    … couplers offer the most satisfactory means of coupling light into thin film optical waveguides. The purpose of this dissertation has been to study the behaviour, both theoretically and experimentally, and fabrication of grating couplers in nonlinear waveguides. A theory of nonlinear grating …

    arizona-thes Repository record for THEORY AND FABRICATION OF SUB-MICRON GRATINGS ON NONLINEAR OPTICAL WAVEGUIDES. (opens in a new tab)

  6. Biomechanics of the Lower Back During Repetitive Deadlifts, with and without Body Armor

    … circular statistics were used to quantify the coupling angle variability between the initial 10% to the final 10% of repetitions performed. Aim 2) A kinematics-drive finite element model was utilized to quantify lumbar spine compression and shear forces, at the L5/S1 level, during deadlift RTF. …

    uky-thes Repository record for Biomechanics of the Lower Back During Repetitive Deadlifts, with and without Body Armor (opens in a new tab)

  7. Using prisms to excite leaky waves or to launch surface electromagnetic waves

    … surface waves. We have also compared the coupling into a single interface to that into a waveguide. We have found that prisms are unable to couple incident laser light in the form of a laser beam with a gaussian profile into leaky surface waves efficiently. Moreover, we have found that …

    must-thes Repository record for Using prisms to excite leaky waves or to launch surface electromagnetic waves (opens in a new tab)

  8. THE CLINICAL USEFULNESS OF VECTOR CODING VARIABILITY IN FEMALE RUNNERS WITH AND WITHOUT PATELLOFEMORAL PAIN

    … clinical application is lacking. Vector coding’s coupling angle variability (CAV) has been introduced as a possible analysis method to quantify joint coordination variability. The purpose of this study was to assess the clinical usefulness of CAV measures from a dynamical systems perspective. This …

    uky-thes Repository record for THE CLINICAL USEFULNESS OF VECTOR CODING VARIABILITY IN FEMALE RUNNERS WITH AND WITHOUT PATELLOFEMORAL PAIN (opens in a new tab)

  9. Colorectal and Ovarian Cancer Imaging Using Optical Coherence Tomography and Photoacoustic Tomography

    … illumination. By controlling the input laser coupling angle and the gradient of the scattering coefficient inside the diffusive layer, a 3-cm long homogeneous illumination pattern can be generated.

    wustl Repository record for Colorectal and Ovarian Cancer Imaging Using Optical Coherence Tomography and Photoacoustic Tomography (opens in a new tab)

  10. Dynamical Quantum Phase Transitions, Scrambling and Quantum Simulations of Many-Body Neutrino Systems

    … analysis reveals a nontrivial dependence on the coupling angle distributions chosen for the two-body interaction term. The results establish two distinct classes of DQPT's in two flavor neutrino systems, verfied via robust statistics. Scrambling as diagnosed by the Out-of-Time-Ordered Correlator …

    washington Repository record for Dynamical Quantum Phase Transitions, Scrambling and Quantum Simulations of Many-Body Neutrino Systems (opens in a new tab)

  11. Joint Coordination Variability In Anterior Cruciate Ligament Reconstructed Subjects During Stair Ambulation Using a Vector Coding Technique

    … ten selected intra-limb knee-knee and knee-hip couplings would be altered in the ACLR group compared to a group of healthy control subjects based on previous findings using similar methods. Thirty subjects (15 ACLR and 15 normal) were analyzed using a motion capture camera system and force …

    tenn-hsc Repository record for Joint Coordination Variability In Anterior Cruciate Ligament Reconstructed Subjects During Stair Ambulation Using a Vector Coding Technique (opens in a new tab)

  12. Evaluating Coordination and Variability Within Collegiate Basketball Players Using Vector Coding

    The countermovement jump (CMJ) is a popular tool used to assess neuromuscular capabilities and production of power. The literature has also shown the CMJ to assess differences in strategic approaches, and it is common to see the variables countermovement depth, impulse, and ground-reaction force …

    usm Repository record for Evaluating Coordination and Variability Within Collegiate Basketball Players Using Vector Coding (opens in a new tab)

  13. Applications of dynamical systems theory and 'complex' analyses to cricket fast bowling.

    … that moderate (0.5+) to very strong (0.9+) coupling relationships existed for the four segment couplings (NBA vs. FL, BA vs. NBA, BA vs. FL, UT vs.P) with the majority of these moving in synchrony. Statistically significant mean differences in both cross-correlation coefficients and average …

    sheffield-hallam Repository record for Applications of dynamical systems theory and 'complex' analyses to cricket fast bowling. (opens in a new tab)

  14. Investigation of Differences in Phasic Patterns During a Multicyclic Fatiguing Task

    … relative phase displayed information of the coupling relationship between the two joints when the distal joint was assessed relative to the proximal joint. The results showed that up to and including the 4th lift the coupling angle of the participants executed an ideal lifting posture where …

    auckland-tech Repository record for Investigation of Differences in Phasic Patterns During a Multicyclic Fatiguing Task (opens in a new tab)

  15. Optical waveguide measurements of reactive low voltage ion plated thin films

    … accuracy /Wes79/. Of the several waveguide coupling techniques possible we chose to use a prism-coupler because it is non-destructive and does not require any special film preparation. The waveguide attenuation (loss) is determined from the light scattered out of the plane of the film. The …

    ucf Repository record for Optical waveguide measurements of reactive low voltage ion plated thin films (opens in a new tab)