Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 45 for “"cross flow velocity"”.
-
ANALYZING THE EFFECT OF CROSS FLOW VELOCITY, UNIFORM TRANS MEMBRANE PRESSURE AND PH ON PERMEATE FLUX, RETENTATE COMPOSITION AND ENERGY CONSUMPTION DURING CROSS FLOW MICROFILTRATION OF SKIM MILK
… 0.2-mm membranes. A factorial design of three cross flow velocities (CFV) of 5.3, 5.8, 6.3 ms-1 and three uniform trans membrane pressures (UTMP) of 68.9, 103.4, 137.9 kPa was utilized. High CFV combined with high TMP required the shortest time (up to 40%) to achieve a concentration factor (CF) …
-
Treatment of Distillery Waste Using Membrane Technology
… performance by comparing it to the conventional cross-flow configuration for both flat sheet and hollow fiber dialysis membranes. The submerged configuration of dialysis process with the aid of membrane transverse vibration offered a promising alternative hydrodynamic approach to the cross-flow …
-
A study of heavy oil ultrafiltration using ceramic membranes
… to examine the effect of membrane pore size, crossflow velocity and membrane regeneration on the permeate flux and asphaltene reduction. Results from the experiments showed that both the flux and the asphaltene concentration of the permeate declined with time due to membrane pore restriction. …
-
The Characterization of Bimodal Droplet Size Distributions in the Ultrafiltration of Highly Concentrated Emulsions Applied to the Production of Biodiesel
… transesterification reaction and the effect of cross flow velocity on separation, various oils were transesterified in another membrane reactor providing higher cross flow velocity. higher cross flow velocity provides better separation by reducing materials deposition on the surface of the …
-
The Effects Of Ceramic Membrane Design And Feed Composition On Serum Protein Removal During Microfiltration Of Skim Milk
… calcium and lactose concentrations, retentate flow channel geometry (round or diamond-shaped), uniform transmembrane pressure (UTP), and retentate flow channel diameter (4 mm or 6 mm) on factors that impact MF process efficiency (SP removal, limiting flux (LF), and limiting retentate protein …
-
An experimental and numerical study of diffusion flames in cross-flow and quiescent environment at smoke point condition.
… smoke point diffusion flame in a quiescent and cross-flow condition was performed. The fuel mass flow rate of a turbulent smoke point flame was determined at a quiescent condition and in cross-flow with velocity ranging from 2 to 4 m/s. This fuel mass flow rate is defined as the Critical Fuel …
-
Modeling irreversible fouling in submerged hollow fiber membrane systems for drinking water treatment
… and the system hydrodynamic conditions (i.e. the cross-flow velocity). The extent of internal/pore fouling was determined to be governed only by the operating permeate flux. In addition, the results from the present study indicated that when operating the membrane filtration system below critical …
-
Agricultural spray droplet dispersion in turbulent windflow
… from sprays by atmospheric or vehicle-generated cross flows, is investigated experimentally. The primary requirement for realistic wind tunnel studies is identified from background review as matching the full-scale logarithmic man velocity profile with suitable surface roughness parameters. A …
-
Break up of a round liquid jet in a low Weber number cross flow.
The break up of a liquid jet in cross flow has applications in fuel atomization processes. The break up of a water jet in a high speed cross flow was studied with momentum ratios ranging between 10 and 172. High-speed camera images showed break up characteristics ranging from bag break up (break up …
-
A study of velocity profile models and wall shear stress for two and three-dimensional turbulent boundary layer flows
A review of the existing, more prominent velocity profile models for two and three-dimensional incompressible flows was presented, with emphasis placed on those that had previously shown their ability to correlate experimental data taken under various conditions. This review included velocity …
-
Ultrafiltration of Alkalilignin Through Dynamic Membranes Formed of Feed Constituents
… the pore size of the support structure and the cross-flow velocity were small on the membrane performance. A temperature increase from 30ºC to 70ºC increased the product flux by 130%. A higher operating pressure increased the product flux only slightly above a critical pressure of about 80 psi. …
-
Characterization of anaerobic membrane digesters for stabilization of waste activated sludge
… fouling control strategies by using low cross flow velocity and pressure anaerobic membrane systems. The study employed a pilot scale anaerobic digester integrated with negative and neutral tubular membranes; pilot and bench scale control digesters supported with bench scale filtration …
-
Investigation of Direct Injection Fuel Sprays in High Velocity Air Flows
The study of single-plume sprays into cross-flowing air is found extensively in literature, however, with the continued development of the Spark Ignition Direct Injection (SIDI) engine, the behaviour of multi-plume sprays in cross-flowing conditions is of interest. In the present work, the …
-
Measurement of hydrodynamic forces and moments and flow field mapping of a model in coning motion
… forces and moments on the body. Specifically, cross coupling terms in roll rate and yaw rate have been investigated for non-planar cross-flow. An instrumented slender body of revolution with length/diameter of 9.5 was tested at Reynolds number of about 5 million, based ol length. The tests were …
-
Simulação numérica do escoamento turbulento em canal composto
… main channels, wider regions where the fluid flows axially more easily, and narrower regions (gaps) where the fluid is decelerated due to the viscous effects. In order to determine the heat transfer coefficients in these channels it is necessary to understand the behavior of the turbulent …
-
Screening of Microfiltration and Ultrafiltration Ceramic Membranes for Produced Water Treatment and Testing of Different Cleaning Methods
… The effects of transmembrane pressure (TMP) and cross flow velocity (CFV) on the permeate quality and flux of the selected MF and UF membranes were investigated. Different membrane cleaning methods including cleaning-in-place (CIP), backwashing and backpulsing were used to clean the fouled UF …
-
Microfiltration membrane fouling by dairy proteins : thesis submitted for the degree of Doctor of Philosophy at Massey University, New Zealand
… μm polysulphone membrane if the combination of cross-flow velocity and permeate flux leads to a concentration of casein at the membrane wall equal to or higher than that required for "gel layer" formation. Once formed, the gel layer restricts the passage of protein through the membrane and …
-
Membrane fouling during microfiltration of protein solutions : thesis submitted for the degree of Doctor of Philosophy at Massey University, New Zealand
Membrane fouling during cross-flow microfiltration (CFMF) of proteins is complex depending upon feed properties, operating conditions and membrane properties. Four different protein solutions (reconstituted whey protein, BSA, lactoferrin and ferritin) with a range of physicochemical properties were …
-
External membrane bioreactor for the anaerobic treatment of low strength municipal wastewater
… at trans-membrane pressure (TMP) of 207 kPa and cross flow velocity (CFV) of 3.3 m/s, the organic membrane exhibited high and stable permeate flux. Membrane permeability decreased with an increase of sludge concentration at TMP of 276 kPa, but was independent of sludge concentration at TMP of 83 …
-
Mechanistic study of ultrafiltration membrane fouling in the separation of molecular-size characterized pulp and paper mill effluents
… variables such as trans-membrane pressure and cross-flow velocity. This model predicted the fluxes for the E- and oxygenated E-stage (E₀) effluents within an error of 9%. The UF membrane fouling by E-stage effluent was quantified employing fouling potential factors. An increase in the molecular …
Page 1 of 3