Modelling of Dynamic Edge Loading in Total Hip Replacements with ceramic on polyethylene Bearings
… joint, mismatch of the component centres or the cup positioning during hip replacement surgery. Experimental studies have shown that these factors can cause the separation of the two components during the walking cycle (dynamic separation) and the contact of the femoral head with the rim of the …
-
The Effect of Variations in Component Positioning and Swing Phase Load on the Occurrence and Severity of Edge Loading and Wear in Hip Joint Replacements
… head contacts the rim section of the acetabular cup. The input conditions of these tests did not allow the individual evaluation of other variables due to the constraints of the methodology. The aim of these studies was to evaluate the effect on the occurrence and severity of edge loading, and …
-
Contact mechanics of metal on polyethylene hip replacements
… bearings, the Charnley hip and the Pinnacle cup system, were investigated. The effect of different factors on the contact mechanics and cement stresses for Charnley THR were examined. Additionally, the contact mechanics and mechanical behaviour of Pinnacle THR under daily activities, standard …
-
Wear of hard-on-hard hip prostheses: influence of head size, surgical position, material and function
… easier to detect clinically which include steep inclination angle and excessive version/anteversion angles. Translational mal-positioning encompasses micro-separation of the centres of rotations of the head and the cup and could occur due to several clinical reasons, such as head offset …
-
Characterisation and In Vitro Simulation of the Natural Hip
… using clinically relevant conditions. The cup inclination angle was set at 45 °, a full ISO14242 gait cycle was applied to the joint with a peak load of 750 N, to account for porcine tissue. No labral or cartilage damage was observed after 10800 cycles. In vitro labral damage was also …
-
Predictive Modeling of Hip Dislocation: Assessment of Surgical and Patient Factors to Reduce the Occurrence of Hip Instability and Adverse Clinical Outcomes
… alignments reported clinically, variation in cup anteversion/retroversion had the largest impact on liner peak loading location of any degree of freedom throughout the prescribed activities. Cup inclination also showed a relationship to response liner loading; stem variation in either …
-
Μικρής παρεμβατικότητας (MIS) προσπέλαση και υλικά (short stem) στην ολική αντικατάσταση της άρθρωσης του ισχίου
… length, longer operating time, higher mean cup inclination, decreased postoperative pain levels the first 6 and 12 h and relatively better clinical and functional results 6 months after surgery. Our study revealed some advantages in favor of the SuperPATH approach comparing with the standard …
-
Pseudotumours following hip resurfacing; minimising the clinical impact
… associated with significantly increased risk; cup malorientation and a reduction in head neck ratio (HNR) at operation particularly in females. Furthermore, evidence based recommendations were provided on optimum cup orientation and screening practice. Surgeons should aim for a radiographic cup …
-
Revisionsraten von Hüftprothesen mit „as cast“ Metall-Metallgleitpaarungen in Abhängigkeit von deren Größe und dem Geschlecht der Patienten
In der Behandlung der fortgeschrittenen, primären und sekundären Hüftgelenksarthrose stellt, nach Ausschöpfung aller konservativen und gelenkerhaltenden operativen Therapiemöglichkeiten, der endoprothetische Gelenkersatz die Methode der Wahl dar. Ende der 1980er Jahre kombinierte McMinn den …