  1. Medial Acetabular Wall Breach in Total Hip Arthroplasty – Is Full-Weight Bearing Possible?

    … acetabular component, and increases the risk for migration of the acetabular component? Hypothesis Immediate full-weight-bearing in the presence of a medial breach is not associated with an increased likelihood for acetabular-related revision surgery or migration of the cup. Patients and methods …

    zurich Repository record for Medial Acetabular Wall Breach in Total Hip Arthroplasty – Is Full-Weight Bearing Possible? (opens in a new tab)

  2. Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies

    … studies have shown that RSA measurements of migration can be used to predict the risk of future revision based on a small group of patients and in a relatively short period of time. This thesis aims to study different aspects of RSA methodology with a potential influence on precision and …

    goteborg Repository record for Wear and migration in total hip arthroplasty measured with Radiostereometric Analysis. Methodological aspects and clinical studies (opens in a new tab)

  3. Comprehensive Assessment of Implant Movement Following Total Hip Arthroplasty: Analysis of Surgical Approach, Implant System, and Imaging Techniques

    … THA. This thesis investigates in vivo implant migration as a predictive marker for aseptic loosening, comparing different surgical techniques and implant designs through radiographic imaging techniques. This thesis utilized the gold-standard radiostereometric analysis (RSA) and explored …

    uwo Repository record for Comprehensive Assessment of Implant Movement Following Total Hip Arthroplasty: Analysis of Surgical Approach, Implant System, and Imaging Techniques (opens in a new tab)

  4. The role of head size in total hip arthroplasty - Dislocation, wear and cup stability

    … related to polyethylene wear, corrosion and cup loosening. Paper I is an observational study that aimed to investigate whether the transition from 28-mm to 32-mm heads and thereafter to 36-mm heads in patients undergoing total hip arthroplasty (THA) after osteoarthritis has been followed by a …

    goteborg Repository record for The role of head size in total hip arthroplasty - Dislocation, wear and cup stability (opens in a new tab)

  5. Factors affecting cup wear and migration in total hip arthroplasty

    … höftproteser behöver omopereras är effekter av cupslitage, det vill säga slitage av plasten som utgör slitytan i den konstgjorda ledpannan (cupen). Detta slitage kan ha olika orsaker och vi har i denna avhandling undersökt några av de faktorer som man tror har störst betydelse för cupslitaget. …

    lund Repository record for Factors affecting cup wear and migration in total hip arthroplasty (opens in a new tab)