Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 34 for “"current distortion"”.

  1. High-Efficiency Three-Phase Current Source Rectifier Using SiC Devices and Delta-Type Topology

    … dissertation, the benefits of the three-phase current source rectifier (CSR) in high power rectifier, data center power supply and dc fast charger for electric vehicles (EV) will be evaluated, and new techniques will be proposed to increase the power efficiency of CSRs.</p> <p>A new topology, …

    utk-theses Repository record for High-Efficiency Three-Phase Current Source Rectifier Using SiC Devices and Delta-Type Topology (opens in a new tab)

  2. Approximate dynamic programming and artificial neural network control of electric vehicles: from motor drives to grid integration

    … vector controller, the IPM encounters high current distortion and speed oscillation especially when working in overmodulation area, due to the decoupling inaccuracy issue. The ADP-ANN controller resolves the decoupling issue and guarantees better speed and current tracking performance. For …

    alabama Repository record for Approximate dynamic programming and artificial neural network control of electric vehicles: from motor drives to grid integration (opens in a new tab)

  3. Position estimation of IMSM using fundamental PWM excitation and its application in sensorless control

    … relating the measured incremental inductance to current derivatives for two or more adjacent PWM voltage vectors applied to the machine. In theory, this sensorless control method can work over a wide speed with lower current distortion, smaller current and torque ripples, power loss and lower …

    unsw Repository record for Position estimation of IMSM using fundamental PWM excitation and its application in sensorless control (opens in a new tab)

  4. Sensorless Control and Fast On-Line Parameter Estimation of IPMSM Based on Current Derivative Measurements

    … signals and extracting the rotor angle from the current response. The fundamental excitation based method is robust at medium and high speed operation; however, at low speed the rate of signal to noise is reduced significantly, leading to the reduction of estimation accuracy. In contrast, the …

    unsw Repository record for Sensorless Control and Fast On-Line Parameter Estimation of IPMSM Based on Current Derivative Measurements (opens in a new tab)

  5. Data Center Power System Emulation and GaN-Based High-Efficiency Rectifier with Reactive Power Regulation

    … with high efficiency. To achieve low input current total harmonic distortion (iTHD), current distortion mechanisms are analyzed, and effective solutions for mitigating current distortion are proposed and validated with experiments.</p> <p>The idea of providing reactive power compensation …

    utk-theses Repository record for Data Center Power System Emulation and GaN-Based High-Efficiency Rectifier with Reactive Power Regulation (opens in a new tab)

  6. COMPARATIVE ANALYSES OF MULTI-PULSE PHASE CONTROLLED RECTIFIERS IN CONTINUOUS CONDUCTION MODE WITH A TWO-POLE LC OUTPUT FILTER FOR SURFACE SHIP DC APPLICATIONS

    … These issues include input Alternating Current (AC) interface requirements, the output Direct Current (DC) load profile, and overall stability in the presence of non-linear loads. Understanding these issues and determining the means of assuring compatibility with a Navy all-electric ship …

    nps Repository record for COMPARATIVE ANALYSES OF MULTI-PULSE PHASE CONTROLLED RECTIFIERS IN CONTINUOUS CONDUCTION MODE WITH A TWO-POLE LC OUTPUT FILTER FOR SURFACE SHIP DC APPLICATIONS (opens in a new tab)

  7. Average current-mode control and charge control for PWM converters

    Two control schemes for PWM converters, average current-mode (ACM) control and charge control, are studied in this dissertation. The small-signal models are derived for continuous-conduction mode PWM converters employing these two controls. Sampled-data modeling is applied to the current loop …

    vt Repository record for Average current-mode control and charge control for PWM converters (opens in a new tab)

  8. HIGH PERFORMANCE POWER CONVERTERS FOR MORE ELECTRICAL AIRCRAFT

    … research on HFLMR has focused on improving the current quality in DCM by revising switching schemes. Novel switching schemes have been proposed and compared with existing switching schemes. The input current distortion can be greatly reduced to THD less than 3% in full load by proposed …

    nus Repository record for HIGH PERFORMANCE POWER CONVERTERS FOR MORE ELECTRICAL AIRCRAFT (opens in a new tab) Download file for HIGH PERFORMANCE POWER CONVERTERS FOR MORE ELECTRICAL AIRCRAFT (opens in a new tab)

  9. Comparative Analysis Of Current Control Methods For Modular Multilevel Converters

    … voltage balancing strategies, and circulating current suppression control. This thesis presents the development of a predictive current control for MMCs that has the benefit of inherently reduced circulating currents within the converter’s phase units. Two other typical MMC current control …

    south-carolina Repository record for Comparative Analysis Of Current Control Methods For Modular Multilevel Converters (opens in a new tab)

  10. Modulation and Control for High-Frequency GaN-Based Bidirectional AC--DC Converters

    Alternating-current--direct-current (AC--DC) converters serve as a critical interface between the electric grid and direct-current (DC) loads. With the increasing demand for data center power consumption, renewable energy systems, energy storage systems, electric vehicles (EVs), AC--DC converters …

    vt Repository record for Modulation and Control for High-Frequency GaN-Based Bidirectional AC--DC Converters (opens in a new tab)

  11. Energy savings on single-phase induction motors under light load conditions

    … Determine a way to smooth out both voltage and current distortion. (D) Verify the simulations with laboratory experiments; It is asserted that most efficient way to run a motor for a given load is to vary the voltage until minimum input power is achieved. However, unlike the Nola concept, the …

    unlv Repository record for Energy savings on single-phase induction motors under light load conditions (opens in a new tab) Download PDF for Energy savings on single-phase induction motors under light load conditions (opens in a new tab)

  12. Projeto de filtros passivos para a redução de correntes harmônicas na subestação de 2x300 kVA da estação elevatória de água do Jiqui

    … Rio Grande do Norte (CAERN). Divergent harmonic currents were observed against the standard recommendations, caused by the use of inverters for driving the motors. To solve this case, this final work presents passive harmonic filters single tuned to be instaled in parallel with the low voltage …

    brazil-ufrn Repository record for Projeto de filtros passivos para a redução de correntes harmônicas na subestação de 2x300 kVA da estação elevatória de água do Jiqui (opens in a new tab)

  13. A benchmarking model for harmonic distortion in a power system

    … are inherently non-linear, which causes the current to deviate from sinusoidal conditions. This phenomenon is known as harmonic current distortion. Multiple consumers are connected to the utility at the point of common coupling. Harmonic currents are then transmitted into the distribution …

    nwu-za Repository record for A benchmarking model for harmonic distortion in a power system (opens in a new tab)

  14. High efficiency and digitally controlled AC-DC converter with power factor correction and fast output voltage regulation

    High efficiency and power factor at light load are increasingly desired in desktop computer power supplies for energy saving initiative and product differentiation with the certification of energy saving programs. However, the efficiency and power factor of power factor correctors (PFCs) in desktop …

    nus Repository record for High efficiency and digitally controlled AC-DC converter with power factor correction and fast output voltage regulation (opens in a new tab) Download file for High efficiency and digitally controlled AC-DC converter with power factor correction and fast output voltage regulation (opens in a new tab)

  15. MOSFET-based MMC for low-voltage DC distribution networks

    … voltage ratings, and elimination of reactive current and skin effect issues. LVDC distribution also complements the growth of power electronic loads having an implicit DC stage as part of their grid interface. However the DC-AC conversion stage at the customer end is one of the main challenges …

    strathclyde Repository record for MOSFET-based MMC for low-voltage DC distribution networks (opens in a new tab)

  16. Comparison of Three Space Vector PWM Methods for a Three-Level Inverter with a Permanent Magnet Machine Load

    … to drive induction machines, in which the rotor currents are induced by stator rotating field effects. However, there are few investigations that analyze these modulation methods applied to permanent magnet (PM) and wound-field synchronous machines, in which the rotor induces a back emf in the …

    marquette Repository record for Comparison of Three Space Vector PWM Methods for a Three-Level Inverter with a Permanent Magnet Machine Load (opens in a new tab)

  17. Theoretical modeling of single-phase power electronics loads to predict harmonic distortion at a distribution feeder network using a reverse optimization solution

    … in thousands of individual small harmonic current injectors connected to a distribution feeder network. Harmonic standard: IEC 1000-3-2 classifies such loads as Class D, “low-voltage” equipment with current emissions limited to 16A/Phase. Individual harmonic contributions of such loads …

    texas Repository record for Theoretical modeling of single-phase power electronics loads to predict harmonic distortion at a distribution feeder network using a reverse optimization solution (opens in a new tab)

  18. Design and Control of Power Converters for High Power-Quality Interface with Utility and Aviation Grids

    … are proposed.• Model and compensate the distortion due to charging transition of device junction capacitances in three-level converters.• Find the previously overlooked device junction capacitance of the nonactive devices in three-level converters, and analyze the impacts on switching …

    utk-theses Repository record for Design and Control of Power Converters for High Power-Quality Interface with Utility and Aviation Grids (opens in a new tab)

  19. Developing fault-tolerant control strategies for a five-phase permanent-magnet machine drive system

    … it allows for the injection of unbalanced phase currents, i.e. currents that do not sum to zero. This allows for better optimization of the machine torque after open-phase faults occur. The post-fault phase currents are often controlled using the field-oriented control (FOC) technique. However, …

    unsw Repository record for Developing fault-tolerant control strategies for a five-phase permanent-magnet machine drive system (opens in a new tab)

Page 1 of 2