Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 229 for “"current measurement"”.

  1. DC Current Measurement Systems for Neurostimulator Implants

    … explores methods of accurately measuring DC current flowing in a circuit sub-block or an entire chip. The major application demonstrated is a novel mixed-signal system to monitor DC current imbalance on the supply/ground lines of the stimulation circuitry in a neurostimulator implant chip, …

    unsw Repository record for DC Current Measurement Systems for Neurostimulator Implants (opens in a new tab)

  2. On-chip current measurement for multi-site electromigration monitoring

    … and thermal issues. Direct and continuous measurement of on-chip currents is becoming increasingly common in interconnects at multiple locations on a die with real time feedback to the controller for efficient load management and/or load balancing and system performance optimization. The …

    iastate Repository record for On-chip current measurement for multi-site electromigration monitoring (opens in a new tab)

  3. Investigation of the two pulse correlation sonar technique for water current measurement

    … correlation sonar technique for measuring water currents in the ocean is investigated. New theoretical analysis is developed to study the operation of the two pulse correlation sonar, including in particular, different de­-modulation techniques, the effect of cross-pulse interference on the …

    uvic Repository record for Investigation of the two pulse correlation sonar technique for water current measurement (opens in a new tab)

  4. Development and Validation of a Current-Based EEG System for Tangential Current Measurement

    … tangential dipoles in the brain, I developed a current-based EEG (cEEG) system. The cEEG has a front-end transimpedance amplifier to measure currents that are caused by tangential dipoles. A one-channel cEEG amplifier was conceptualized, designed, simulated, implemented, and characterized for …

    calgary Repository record for Development and Validation of a Current-Based EEG System for Tangential Current Measurement (opens in a new tab)

  5. Examination of transient carrier behaviors in organic field-effect devices via displacement current measurement.

    … based on steady state or quasi steady state DC measurements, which are not sensitive to transient processes including the formation and depletion of the conducting channel. These transient processes are essential parts of the device operation, and determine the response frequency of OFETs. For …

    umn Repository record for Examination of transient carrier behaviors in organic field-effect devices via displacement current measurement. (opens in a new tab)

  6. An investigation of the noise signals associated with current measurement in a pulsed discharge circuit

    A Rogowski coil has been used for the measurement of a pulsed discharge current. The frequency response of the coil is discussed, and a method which extends this response to higher frequencies (100 Mc/s) is described. It has been found that the noise signals associated with the measurement of a …

    ubc Repository record for An investigation of the noise signals associated with current measurement in a pulsed discharge circuit (opens in a new tab) Download PDF for An investigation of the noise signals associated with current measurement in a pulsed discharge circuit (opens in a new tab)

  7. A contactless and non-intrusive current measurement technique for low and medium voltage AC power systems

    The real-time state of current is essential to precisely monitor and control the AC power systems. It is also crucial for detecting various types of faults that may lead to long duration and wide area outages and affect the reliability and dependability. Traditional core wound window type current …

    uoit Repository record for A contactless and non-intrusive current measurement technique for low and medium voltage AC power systems (opens in a new tab)

  8. Ultra-fast Alternating Current Potential Drop Measurement System for Materials Characterization and Precision Impedance Analyzer for Eddy Current Measurement

    <p>The alternating current potential drop method (ACPD) with four-point probe injects alternating current into the sample under test from the two outer drive pins and measures the voltage (potential) drop between the two inner pick-pins. This method can be used to measure electrical conductivity, …

    iastate Repository record for Ultra-fast Alternating Current Potential Drop Measurement System for Materials Characterization and Precision Impedance Analyzer for Eddy Current Measurement (opens in a new tab)

  9. Detection and localization of events in computer networks using end-to-end measurements time series

    … ISP’s network’s characteristics, and the current measurement process, this dissertation aims to check the viability of only using end-to-end QoS measures, and traceroutes, to identify and localize network events. An event can be interpreted as a behavioral change in a network equipment, …

    brazil-uerj Repository record for Detection and localization of events in computer networks using end-to-end measurements time series (opens in a new tab)

  10. Sensorless Control Techniques for the Flyback-Type Solar Tile Microinverter

    … operating a photovoltaic (PV) microinverter, the current must be measured to perform maximum power point tracking (MPPT). The current measurement is required as it is used to calculate the power generated by the PV module. This dissertation studies the operation of a flyback-type PV microinverter …

    calgary Repository record for Sensorless Control Techniques for the Flyback-Type Solar Tile Microinverter (opens in a new tab)

  11. Electron Detection Systems for KATRIN Detector and Spectrometer Section

    … upcoming KATRIN experiment beta-decay spectrum measurement, and methods toward the necessary passive detection of a single electron through a large aperture are explored. A sub-fA current measurement was performed to determine the detector system's absolute detection efficiency, and faults in …

    washington Repository record for Electron Detection Systems for KATRIN Detector and Spectrometer Section (opens in a new tab)

  12. Development of a Novel Cognitive-Motor Dual Task Assessment Battery in Neurodegenerative Disease

    … to subtle, subclinical impairments. However, current measurement of automaticity by dual task paradigms is methodologically limited. In order to gain insight into the current state of the literature regarding cognitive-motor interference in symptomatic and prodromal neurodegenerative disease, …

    unlv Repository record for Development of a Novel Cognitive-Motor Dual Task Assessment Battery in Neurodegenerative Disease (opens in a new tab) Download PDF for Development of a Novel Cognitive-Motor Dual Task Assessment Battery in Neurodegenerative Disease (opens in a new tab)

  13. Ω-shaped Rogowski Coil Current Sensor Optimization Design in Power Electronics Applications

    Accurate switching current measurement plays a pivotal role in characterization of power devices, overcurrent protection, and real-time control of system-level operations in power electronics applications. However, the ongoing revolution in power electronics, driven by the emergence of wide bandgap …

    arkansas Repository record for Ω-shaped Rogowski Coil Current Sensor Optimization Design in Power Electronics Applications (opens in a new tab)

  14. Building a foundation for proactive quality management

    … the issue at hand, as well as an analysis of the current situation. Since the project was conducted using the DMAIC methodology, the current measurement system will be explained. Furthermore, the thesis contains an extensive analysis of both the currently identified process deviations and the …

    chalmers Repository record for Building a foundation for proactive quality management (opens in a new tab)

  15. Switched aperture surface current measurements

    The measurement of induced surface currents on antennas, scatterers, and other structures is important for a variety of reasons, including in-situ measurements and validation of simulated results. Techniques for measuring the complete vector nature of surface currents (magnitude, direction, and …

    uiuc Repository record for Switched aperture surface current measurements (opens in a new tab)

Page 1 of 12