Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 47 for “"cutpoint"”.
-
Optimal cutpoint determination via design theory for regression models
… is how to optimally choose a set or sets of cutpoints (in a categorized survey question) which are offered to respondents. In the case of several sets, a further issue is how to allocate sampled subjects to these sets (design points). Applications include Contingent Valuation (CV) studies …
-
Finding the Cutpoint of a Continuous Covariate in a Parametric Survival Analysis Model
… groups. The goal of this work is to find the cutpoint of a continuous variable where the transition occurs from low to high risk group. Different methods have been published in literature to find such a cutpoint. We extended the methods of Contal and O’Quigley (1999) which was based on the …
-
Statistical Inference Methods for Predictive Classification based on Baseline Clinical Variables or Biomarkers
… between treatment and subgroup. In practice, a cutpoint estimate is usually required to define the subgroup, especially when only a single continuous biomarker is available. However, in much of the clinical literature this cutpoint is treated as fixed and known, which can inflate type I error …
-
A circumferential slot virtual impactor for bioaerosol concentration
… latex beads. The test results found a cutpoint Stokes number of 0.75 and 90% particle transmission at least 52X the Stokes cutpoint. At a flow rate of 10 L/min the cutpoint is 2.0 µm aerodynamic diameter (AD) and >90% transmission efficiency was found between 4 mm AD, and 22 µm AD. At …
-
A two-stage 100 l/min circumferential slot virtual impactor system for bioaerosol concentration
… for nominal operational conditions of a 2 μm AD cutpoint, an aerosol inflow to the first stage of 100 L/min and a minor flow rate from the second stage of 1 L/min. Each unit was tested separately before being combined in the system. However, because of high inter-stage losses, a sheath air system …
-
Bayesian inference for ordinal data
… latent variables and ordinal outcomes using cutpoint parameters. However, the convergence of this Gibbs sampler is slow when the sample size is large because the cutpoint parameters are not efficiently sampled. Cowles proposed a Gibbs/Metropolis-Hastings (MH) sampler that would update …
-
The inline virtual impactor
… fraction in a 100 L/min flow and provide a cutpoint particle size of 10 µm, with a pressure drop of 45 Pa. An inverted dual cone configuration encased inside a tube provides the IVI-100 with a characteristic circumferential slot of width 0.254 mm (0.100 inches) and a slot length of 239 mm …
-
Korrelation von Entzündungswerten mit den intraoperativen und histopathologischen Befunden bei der akuten Appendizitis und Cholezystitis
… Befund der Appendizitis. Es konnte ein Cutpoint des CRP-Wertes für den intraoperativen Befund Appendixperforation von 63,85 mg/l (Sensitivität = 0,80, Spezifität = 0,73) errechnet werden. Beim der perforierten Cholezystitis lag der Cutpoint bei einem CRP-Wert von 120,90 mg/l …
-
Evaluation of PM10 and Total Suspended Particulate Sampler Performance Through Wind Tunnel Testing
… (MMDs) that are larger than the 10 μm sampler cutpoint. For industries to be regulated equitably, these sampler errors must be quantified and understood. This research evaluates the performance of FRM PM10 and low volume total suspended particulate (TSP) samplers under the controlled conditions …
-
Two linear slot nozzle virtual impactors for concentration of bioaerosols
… predicted from the literature to produce a cutpoint of 0.8 µm AD, an acoustic resonance was observed, corresponding to significant nozzle wall losses of particles and an absence of normal particle separation in the virtual impactor. The onset of the resonance phenomenon was observed to begin …
-
FLUID AND PARTICLE DYNAMICS IN AN AEROSOL VIRTUAL IMPACTOR
… This work presents the simulation of a low cutpoint, high volume aerosol sampling device known as the "virtual impactor". A steady state, three dimensional RANS type calculation is done using the FLUENT(TM) computational fluid dynamics code to predict the turbulent flow field inside the …
-
Universal Suicide Risk Screening in the Parkland Health and Hospital System: Evaluation of the Parkland Algorithm for Suicide Screening
… CI95=.77, .81). This study also evaluated the cutpoints separating suicide risk stratification and levels of clinical response. The results supported the first cutpoint and highlighted a need for additional data to address the second cutpoint. The results of the present study suggest that the …
-
Multi-stage linear slot virtual impactor for concentration of bioaerosols
… was systematically studied and suppressed. The cutpoint for the first arrangement was 1.3µm AD, and the cutpoint for the second arrangement was 1.0 µm AD. The average Stk50 for both arrangements was 0.71. The throat velocity through the impactors ranged from 21.8 m/s to 73 m/s, and the peak …
-
Validity and Diagnostic Accuracy of a Clinical Trial Battery for Primary Brain Tumor Patients
… clinician ratings of NCF impairment status, at cutpoint -0.50, NCF6Z demonstrated sensitivity = 0.86, specificity = 0.78, PPV = 0.80, and NPV = 0.85. At cutpoint -0.6257, NCF6Z displayed optimal diagnostic accuracy (sensitivity = 0.85, specificity = 0.83, PPV = 0.84, NPV = 0.84). Addition of BD …
-
Formal equivalence checking of software specifications vs. hardware implementations
… number of paths. I first adapt the concept of cutpoints from hardware verification and define the analogous concept of software cutpoints, then implement a proof-of-concept cutpoint approach in my verification tool for the TI C6x family of DSPs. Experimental results show large improvements in …
-
Application of computational fluid dynamics to aerosol sampling and concentration
… is shown to cause the device to have a smaller cutpoint Stokes number than the single impaction unit. The size ratio of the well-to-jet was analyzed to find its influence on the total and side collections. Simulation is used to analyze liquid film, flow structure, particle collection, pressure …
-
COMPARISONS OF WAIST CIRCUMFERENCE, WAIST-TO-HIP RATIO AND BODY MASS INDEX AND THEIR ASSOCIATIONS WITH TYPE 2 DIABETES IN RURAL AND URBAN INDIA
… receiver operator curve (ROC) the anthropometric cutpoints most strongly associated with T2DM were determined. Bivariate correlation and the area under the ROC curve showed most significant associations between T2DM and WHR (0.90 cm, 0.86; 0.87, 0.81 urban and rural men and women, respectively) …
-
Penalized Likelihood Ratio Test for Effect Heterogeneity in Biomarker Cut-Point Model based on Accelerated Failure Time Regression
… characteristics. Identifying optimal biomarker cutpoints is critical for categorizing patients into subgroups with distinct treatment responses. However, determining these cutpoints introduces statistical challenges such as data-driven selection bias, multiple comparisons, and the need for …
-
Validation of the TRISS model of survival in blunt trauma patients using the Ontario Trauma Registry.
… specificity (using probability of survival cutpoint of 50%) and the area under the receiver operating characteristic (ROC) curve. (Abstract shortened by UMI.)
-
Exploring Children’s Physical Activity Levels Through Structure and Measurement
… 5-11 year old children and ultimately create a cutpoint threshold to distinguish seated sedentary behavior from light physical activity. 167 children, ages 5-11 years, performed up to 8 sedentary activities for 5 minutes while wearing ActiGraph GT3X+ accelerometers on both wrists. Participants …
Page 1 of 3