Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 27 for “"cyclone separator"”.
-
Modelling and performance evaluation of a soot cyclone separator
… reports on the performance of a cyclone separator used to remove excess soot that is typically formed during the production of pebble fuel for High Temperature Gas-cooled Reactors. A chemical vapour deposition process is used to manufacture TRISO-coated fuel particles and during …
-
Errors in sampling particulate flows with a 10-mm Dorr-Oliver cyclone separator.
… and mannequin-mounted 10mm Dorr-Oliver nylon cyclone as a particle preclassifier for respirable dust sampling was experimentally determined relative to an isokinetic sampler (sampling efficiency) and an inlet simulator sampler (penetration). A TSI Aerodynamic Particle Sizer (APS 3310) and a …
-
Fluid Flow and Performance Characteristics of a Cyclone Separator Operating Under Side Stream Conditions
… investigation of the flows in a high efficiency cyclone separator and the performance characteristics of the cyclone when operating under the influence of base suction.<br/><br/>It has long been accepted that a bleed taken from the base region of a cyclone could, generally, enhance the overall …
-
CFD-DEM simulation of complex particle-fluid flows
… example pneumatic conveying systems, cyclonic separator unit operations, circulating fluidised beds and dense medium cyclones) are encountered in many industries including energy, mineral, metallurgical, petroleum, environmental, pharmaceutics and materials, and is core in process/chemical …
-
Modulair-C redesign av kombiaggregat 500 ex
… The final solution features a maintenance-free cyclone separator, an improved filter system and a digital user interface. The unit has been redesigned both technically and aesthetically to enable easier installation, improved service ergonomics, and an enhanced user experience. The project also …
-
Particle Morphology and Elemental Composition of Heavy Fuel Oil Ash at Varying Atomization Pressures
… immediately following combustion (pre-cyclone), from a cyclone separator (cyclone), and finally from a position located after the cyclone separator (post-cyclone). A Philips XL30 Scanning Electron Microscope (SEM) provided images, weight percent of elements of the ash, and element maps. …
-
ON THE POTENTIAL OF LARGE EDDY SIMULATION TO SIMULATE CYCLONE SEPARATORS
… with the most common reverse flow type of cyclones where the flow enters the cyclone through a tangential inlet and leaves via an axial outlet pipe at the top of the cyclone. Numerical computations of two different cyclones were based on the so-called Stairmand cyclone. The difference in …
-
Measurements of fine particulate matter in Houston
… and January 31, 2000. PM2.5 was isolated with a cyclone separator and quantified through gravimetric analysis. The major gaseous species (SO 2, gaseous NO3, NH3) and chemical species (organic carbon, elemental carbon, SO42--, NO3 --, NH4+, Na +, K+, and Cl--) were collected by multiple types of …
-
Development of a Low-Cost Incinerator in Cape Maclear, Malawi
… of one week. Additionally, the integration of a cyclone separator within a De Montfort incinerator mark 8A is proposed to reduce particulate matter emissions, albeit with a 12% increase in construction expenses. However, significant challenges persist, particularly regarding ash storage, …
-
Helical Models of the Bidirectional Vortex in a Conical Geometry
… double helical motion often found in industrial cyclone separators. Other applications include cone-shaped, vortex-driven combustion chambers and the swirling flow through conical devices. Both solutions are derived from first principles and Euler’s equations of motion which showcase the stream …
-
Konstruktion av anordning för att undersöka förslitning av syrebärarpartiklar för kemcyklisk förbränning
… is supposed to emulate the attrition caused by a cyclone separator and its advantages are that it is possible to use small test amounts, 5-10 g, and a thirty minutes long test will be enough to acquire useable results. An device was designed based on the Jet-Cup method with some slight …
-
A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth
… an ultrasonic pumping system, a size-selective cyclone separator, and a filter. Filter measurements can be used to correct the output from a low-cost direct-reading PM2.5 sensor housed within the SPARC. AOD is measured using optically filtered photodiodes at four discrete wavelengths. A suite of …
-
Mechanisms affecting the interaction between turbulent boundary layers and compliant surface deformation
… index-matched water tunnel equipped with a cyclone separator, designed to continuously reduce the freestream bubble concentration. Simultaneous time-resolved measurements of wall deformation and the 3D velocity and pressure fields are performed by integrating Mach Zehnder Interferometry with …
-
Developing Co-current and Counter-current Spray Drying Computational Fluid Dynamics (CFD) Simulation Studies to Predict the Quality of Microencapsulated Fish Oil with Egg White Hydrolysates Powders
… particles from drying air at the spray dryer’s cyclone separator was evaluated using CFD. CFD models predicted the drying air flow pattern, particle histories including temperature, residence times (RT), moisture content and particle size of the microencapsulated powders. Predicted moisture …
-
Optimizing the efficiency of cylindrical cyclone gas/liquid separators for field applications
… associated with the use of compact cylindrical cyclone gas/liquid (CCGL) separators can be attributed to two physical phenomena: gas carry-under and liquid carryover (LCO). Inadequate understanding of the complex multiphase hydrodynamic flow pattern inside the cylindrical separator has inhibited …
-
Optimization of Integrated Reservoir, Wellbore, and Power Plant Models for Enhanced Geothermal Systems
… over the 30-year operating lifetime, the cyclone separator should operate at 205°C and the flash vessel should operate at 125°C.
Page 1 of 2