Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 28 for “"datacube"”.

  1. The Design and Analysis of Computed Tomographic Imaging Spectrometers (CTIS) Using Fourier and Wavelet Crosstalk Matrices

    … matrices. These matrices and theircorresponding datacube reconstruction algorithms explicitly usedsensitivity equations describing the CTIS imaging system. Theseequations derived from Franhofer diffraction theory of thecomputed generated hologram (CGH) disperser, serve as themathematical model of …

    arizona-thes Repository record for The Design and Analysis of Computed Tomographic Imaging Spectrometers (CTIS) Using Fourier and Wavelet Crosstalk Matrices (opens in a new tab)

  2. Uniformity correction for infrared IR-CCD camera

    … for an infrared camera. More specifically, a Datacube Image System was used to simulate the three uniformity correction schemes for a 320x244-element IR-CCD TV camera with PtSi Schottky-barrier detectors. The three uniformity correction schemes are: one-point uniformity correction with single …

    njit Repository record for Uniformity correction for infrared IR-CCD camera (opens in a new tab)

  3. Seeing Beyond Sight: The Adaptive, Feature-Specific, Spectral Imaging Classifier

    … only after reconstruction of the spectral datacube, which can have upwards of 10⁹ signal elements. In this dissertation, I present a computational spectral imaging system, the Adaptive Feature-Specific Spectral Imaging Classifier (AFSSI-C), which yields direct classification across the …

    arizona-thes Repository record for Seeing Beyond Sight: The Adaptive, Feature-Specific, Spectral Imaging Classifier (opens in a new tab)

  4. Automatic infrared inspection of solder joints on mounted circuit boards

    … consisting of a SUN workstation and several DATACUBE modules, is set up for the research. Software packages for imaging, displaying and solder joint inspection are developed and ready for public usage.</p><p>The capability of infrared inspection for solder joints on PCBs is demonstrated. The …

    njit Repository record for Automatic infrared inspection of solder joints on mounted circuit boards (opens in a new tab)

  5. Visual tracking using correlation techniques : algorithms, analysis, and pipeline architecture implementation

    … was implemented on a VME rack equipped with a Datacube MV20 pipeline processor and a Motorola 68030 processor. A data update rate of 15hz was achieved.</p>

    ut-knoxville Repository record for Visual tracking using correlation techniques : algorithms, analysis, and pipeline architecture implementation (opens in a new tab)

  6. Development of Image Mapping Spectrometer (IMS) for hyperspectral microscopy

    … instrument that captures a hyperspectral datacube without scanning. It also allows" full" light throughput across the whole spectral collection range due to its snapshot operating format. The developments of three generations of the IMS (low sampling prototype, high sampling IMS, …

    rice Repository record for Development of Image Mapping Spectrometer (IMS) for hyperspectral microscopy (opens in a new tab)

  7. Snapshot Hyperspectral Imaging for Complete Fundus Oximetry

    … situations. Additionally, the system overcomes datacube size limitations imposed by detector array size limits. The work done in this thesis also advances oximetry of the retina using data collected by the Image Mapping spectrometer (IMS), a snapshot spectrometer. Hyperspectral images of the …

    rice Repository record for Snapshot Hyperspectral Imaging for Complete Fundus Oximetry (opens in a new tab)

  8. Development of a model for an objective minimum resolvable temperature difference characterization of an infrared camera

    … for this task is made up of MaxVideo boards from Datacube, inc. Subjectively evaluated MRTDs at various spatial frequencies and the results obtained from this method are compared.

    njit Repository record for Development of a model for an objective minimum resolvable temperature difference characterization of an infrared camera (opens in a new tab)

  9. Development of Hyperspectral Imagers for Snapshot Optical Coherence Tomography

    … simultaneously collect signals of a volumetric datacube, enabling cellular visualization of scattering biological samples. This system affords diffraction-limited performance with reduced motion and requires minimal computational time.

    rice Repository record for Development of Hyperspectral Imagers for Snapshot Optical Coherence Tomography (opens in a new tab)

  10. Compressive Foveation and Spectrally Multiplexed Microscopy

    … for the subsampling of the high-dimensional datacube, but is limited by long L1 reconstruction times. Therefore, here we demonstrate new approaches in reducing the time required to acquire and reconstruct the data for compressive hyperspectral images and video in multiplexing cameras. In the …

    rice Repository record for Compressive Foveation and Spectrally Multiplexed Microscopy (opens in a new tab)

  11. A real-time snapshot hyperspectral endoscope and miniature endomicroscopy objectives for a two field-of-view (Bi-FOV) endoscope

    … of 5.2 fps while collecting a 3D (x, y, gamma ) datacube of 350 x 350 x 48. We have successfully imaged tissue in vivo resolving tissue vasculature and oxy-hemoglobin which are important early cancer biomarkers.

    rice Repository record for A real-time snapshot hyperspectral endoscope and miniature endomicroscopy objectives for a two field-of-view (Bi-FOV) endoscope (opens in a new tab)

  12. Design of a 320X122 MWIR-CCD PtSi-Si imaging radiometer with automatic optical integration time control

    … was developed to connect the camera system to a Datacube processor. Additional circuitry enabled all frame rates to be displayed on an RS-170 monitor after processing. This system was designed to monitor the temperature of semiconductor wafers in Rapid Thermal Processing (RTP) reactors acting as …

    njit Repository record for Design of a 320X122 MWIR-CCD PtSi-Si imaging radiometer with automatic optical integration time control (opens in a new tab)

  13. Techniques for Accelerating Aggregated Range Queries on Large Multidimensional Datasets in Interactive Visual Exploration

    … solve. GaussianCubes significantly improves on datacube-based systems by providing interactive modeling capabilities, which include but are not limited to linear least squares and principal components analysis. NeuralCubes leverage the recent advancement in deep neural networks to learn a model …

    arizona-thes Repository record for Techniques for Accelerating Aggregated Range Queries on Large Multidimensional Datasets in Interactive Visual Exploration (opens in a new tab)

  14. Compressive Hyperspectral Video Detection and Imaging

    … redundancy in the 4D temporal-spatio-spectral datacube. Using this system, single-pixel hyperspectral video imaging that achieves a compression ratio of 900 to 1 is demonstrated.

    rice Repository record for Compressive Hyperspectral Video Detection and Imaging (opens in a new tab)

  15. Design and Fabrication of Snapshot Imaging Spectrometers for Biomedical and Remote Sensing Applications

    … mirrors and achieves significantly increased datacube size and dynamic range compared to previous generations. This benefits from a novel design and fabrication method for making the large-format multifaceted mapping mirrors based on the two-photon grayscale lithography (2GL) mode from a …

    rice Repository record for Design and Fabrication of Snapshot Imaging Spectrometers for Biomedical and Remote Sensing Applications (opens in a new tab)

  16. Imaging White Blood Cells using a Snapshot Hyper-Spectral Imaging System

    … range of 419 to 494nm. Open-source hyperspectral datacube analysis tools, used primarily in Geographic Information Systems (GIS) applications, indicate that white blood cells' features are most prominent in the 428-442nm band for blood samples viewed under 20x and 50x magnification over a varying …

    wvu Repository record for Imaging White Blood Cells using a Snapshot Hyper-Spectral Imaging System (opens in a new tab)

  17. Light-Guide Snapshot Imaging Spectrometer for Biomedical Applications

    … by a CCD camera. To extract the (x, y, λ) datacube from the raw image, a spectral calibration algorithm is implemented to locate each wavelength and obtain point spectrum. Then a phase-shifting spatial calibration procedure is performed to remap the fibers and reconstruct single channel …

    rice Repository record for Light-Guide Snapshot Imaging Spectrometer for Biomedical Applications (opens in a new tab)

  18. Advancement of fiber image guide based snapshot imaging spectrometer technology for bioimaging and environmental applications

    … fast, snapshot acquisition of the hyperspectral datacube and then quick turnaround of raw data into decipherable hyperspectral images and spectra. Previous implementations of fiber based imaging spectrometers were focused on breadboard proof of concept designs and were not optimized for field …

    rice Repository record for Advancement of fiber image guide based snapshot imaging spectrometer technology for bioimaging and environmental applications (opens in a new tab)

  19. Measuring Galaxy Asymmetry in Different Dimensions

    … the 1D spectral or spatial 2D components of datacubes and are computed using absolute values. We show how asymmetry can be generalised to utilise the full 3D of the datacube. Additionally, the absolute difference method is shown to entangle noise and signal into the measure. Instead, we …

    queens Repository record for Measuring Galaxy Asymmetry in Different Dimensions (opens in a new tab)

  20. Versatile Compressive Sensing: Extensions of Random Projections for Imaging and Machine Vision

    … compressively capture the entire hyperspectral datacube at the camera's pixel resolution in a single image. The proposed snapshot camera is compact and requires no moving parts or spatial-light modulators

    rice Repository record for Versatile Compressive Sensing: Extensions of Random Projections for Imaging and Machine Vision (opens in a new tab)

Page 1 of 2