Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 442 for “"dc link"”.

  1. SiC converter for electrical vehicle - DC-link ripple

    … in drivetrains. In most of these inverters, the DC-link capacitor makes up a large portion of the total inverter volume and weight. It is therefore interesting to analyze the DC-link current and voltage ripple which is one of the major dimensioning factors of the DC-link capacitor. Throughout …

    chalmers Repository record for SiC converter for electrical vehicle - DC-link ripple (opens in a new tab)

  2. Reducing DC-Link Capacitance Requirements in Large Wind Turbines

    … to determine a practical method to reduce the DC-Link voltage ripple in large wind turbines. Various wind energy conversion system configurations have been discussed and analysed in the literature review. One of the key issues found are the requirement for devices to be connected in series in …

    bristol Repository record for Reducing DC-Link Capacitance Requirements in Large Wind Turbines (opens in a new tab) Download PDF for Reducing DC-Link Capacitance Requirements in Large Wind Turbines (opens in a new tab)

  3. Condition Monitoring of DC-Link Capacitor in Traction Inverters

    … poses additional challenge for reliability. The DC-link capacitor which links the power source, typically a battery, with the load - an electric machine, performs a critical function of reducing the voltage and current ripple induced mainly by the switching action of IGBTs in inverter module. …

    chalmers Repository record for Condition Monitoring of DC-Link Capacitor in Traction Inverters (opens in a new tab)

  4. A Brushless DC Motor Drive Without a DC Link Capacitor

    … context of industrial motor drives, Brushless DC (BLDC) and Permanent Magnet Synchronous (PMS) motors have become popular as energy efficient and reliable alternatives for induction motors. Both BLDC and permanent magnet synchronous motors are electronically commutated based on the position of …

    auckland-ms Repository record for A Brushless DC Motor Drive Without a DC Link Capacitor (opens in a new tab)

  5. A New Quasi Resonant Dc-link For Photovoltaic Micro-inverters

    … technology is summarized. A new quasi resonant DC link that allows for pulse- width- modulation (PWM) is presented in this thesis. The proposed quasi resonant DC link provides zero-voltage switching (ZVS) condition for the main devices by resonating the DC-link voltage to zero via three …

    ucf Repository record for A New Quasi Resonant Dc-link For Photovoltaic Micro-inverters (opens in a new tab)

  6. ACTIVE AND REACTIVE POWER CONTROL IN BIDIRECTIONAL DC-LINK CONVERTER

    Three phase DC-link converters are popular choice in renewable energy systems and micro-grids. They employ hex bridge converters which allow bidirectional power flow. Due to intermittent nature of most renewable energy systems and varying loads in microgrids, it is important to have a reliable and …

    mtu Repository record for ACTIVE AND REACTIVE POWER CONTROL IN BIDIRECTIONAL DC-LINK CONVERTER (opens in a new tab)

  7. Virtual resistance based DC-link voltage regulation for Microgrid DG inverters.

    … research presents a Virtual Resistance based DC Link Voltage Regulation technique which will allow DG inverters to continue to source their available power even when the power demand by the load is higher than their capacity without shutting off and isolating from the MG.

    ucf Repository record for Virtual resistance based DC-link voltage regulation for Microgrid DG inverters. (opens in a new tab)

  8. Resonant DC link converters and their use in rail traction applications

    … Particular attention is given to the ResonantDC Link Inverter (RDCLI) which shows a great deal of pronuse using currently availabledevices.The frequency domain simulation of RDCLIs is discussed as a means of rapidly evaluatingcircuit behaviour, especially in relation to modulation strategies. …

    salford Download PDF for Resonant DC link converters and their use in rail traction applications (opens in a new tab)

  9. CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES WITH SMALL DC-LINK CAPACITOR

    … machine (PMSM) drive systems with small dc-link capacitor. In small dc-link capacitor-based PMSM drive systems, the dc-link voltage is subject to fluctuations, and thus, real-time accurate dc-link voltage information is critical. This thesis firstly analyses the challenges posed by …

    whiterose Download PDF for CONTROL OF PERMANENT MAGNET SYNCHRONOUS MACHINES WITH SMALL DC-LINK CAPACITOR (opens in a new tab)

  10. DC-link Voltage Control for Reliable Operation of Low-voltage Islanded Microgrids

    … Secondly, a voltage-band is introduced into the dc-link voltage control to deliver unaffected terminal voltage. This control method maintains voltage stability, hence improving power quality during short disturbances in a network such as load changes. This voltage-band, applied to act as an …

    unsw Repository record for DC-link Voltage Control for Reliable Operation of Low-voltage Islanded Microgrids (opens in a new tab)

  11. Three-Phase Unfolding Based Soft DC-Link Converter Topologies for AC to DC Applications

    … current.’ A battery requires ‘direct current’ (DC) source to charge it. Hence a power converter that converts AC source to DC source is required to charge an electric vehicle battery. Public transportation is another sector that is adapting electric vehicles at a fast pace. These vehicles …

    utahstate Repository record for Three-Phase Unfolding Based Soft DC-Link Converter Topologies for AC to DC Applications (opens in a new tab)

  12. Grid-Forming Converter Control Method to Improve DC-Link Stability in Inverter-Based AC Grids

    … inverters, as well as the dynamics of the dc source connected to the inverter. This dissertation aims to highlight the shortcomings of conventional controllers and derive an improved grid-forming inverter controller that is effective in parallel ac operation without sacrificing dc-link …

    utk-theses Repository record for Grid-Forming Converter Control Method to Improve DC-Link Stability in Inverter-Based AC Grids (opens in a new tab)

  13. Analysis and reduction of dc-link capacitor voltage/current stress in three-level PWM converters

    … systems. This Thesis focuses on the converter dc-link capacitor (bank), which is a costly component and a common source of failures. The Thesis is divided into two parts.<br/><br/>The first part examines the voltage and current stress induced on dc-link capacitors by the three most common …

    soton Download PDF for Analysis and reduction of dc-link capacitor voltage/current stress in three-level PWM converters (opens in a new tab)

  14. A new switching technique for minimisation of DC-link capacitance in switched reluctance machine drives.

    … de-fluxing energy in stator windings back to the dc-link results in a large dc-link capacitance. This limits its applications where weight and size of the drive are restricted. This thesis describes a control technique for the dc-link capacitance minimisation in an SR drive. The proposed control …

    whiterose Download PDF for A new switching technique for minimisation of DC-link capacitance in switched reluctance machine drives. (opens in a new tab)

  15. Design criteria for DC link filters in a synchronous generator-phase controlled rectifier-filter-load system

    … can be considered for use in large, high power dc electrical distribution systems. The proposed Navy DC Zonal Electrical Distribution System (DC ZEDS) being designed for the new DD-21 utilizes a rectified ac generator output which is filtered and stepped to usable voltages by local dc-dc …

    nps Repository record for Design criteria for DC link filters in a synchronous generator-phase controlled rectifier-filter-load system (opens in a new tab)

Page 1 of 23