Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"dead volume"”.

  1. Dead Volume Effects in Passive Regeneration: Experimental and Numerical Characterization

    … data to interpret regenerator performance. The dead volume is investigated quantitatively and considered to affect the regenerator performance adversely.

    uvic Repository record for Dead Volume Effects in Passive Regeneration: Experimental and Numerical Characterization (opens in a new tab)

  2. Improving micro free flow device performance

    … stability of separated analyte streams and zero dead volume connections to these devices must be addressed. This work will detail a simple, yet effective, way for mitigating the effects of electrolysis bubbles on analyte stream stability in micro free flow electrophoresis devices by addition of …

    umn Repository record for Improving micro free flow device performance (opens in a new tab)

  3. DNA oligonucleotide synthesis in a microdevice for multiple analytical applications

    … is developed. The microvalves have zero dead-volume characteristic that is attributed to the design of zigzag shaped main channel and special position of each microvalve. This design removes the connecting channels between the microvalve and the main channel that are usually found in …

    nus Repository record for DNA oligonucleotide synthesis in a microdevice for multiple analytical applications (opens in a new tab) Download file for DNA oligonucleotide synthesis in a microdevice for multiple analytical applications (opens in a new tab)

  4. Estudio teórico-experimental de compresores de pistón herméticos con diferentes refrigerantes

    … model allows obtaining an estimation of the volumetric efficiency and the compressor when the refrigerant with an error lower than 3% in most of the tested working conditions. Finally, the development of the model has pointed out the possibility of the existence of an effect of condensation of …

    upv Repository record for Estudio teórico-experimental de compresores de pistón herméticos con diferentes refrigerantes (opens in a new tab)

  5. Regra de operação de reservatório isolado no semiárido: uma aplicação da lógica fuzzy

    … resilience, vulnerability and time on dead volume. Thus, the rules with the best performance in mitigating water scarcity during the dry season, in decreasing order, were FHR, HR and SOP. The improvement is evidenced by the increase in efficiency in meeting priority demands, such as, …

    brazil-ufrn Repository record for Regra de operação de reservatório isolado no semiárido: uma aplicação da lógica fuzzy (opens in a new tab)

  6. Novel detection alternatives for capillary electrokinetic separations

    … developed and employed in the production of low dead volume junctions for two novel detectors. The application of the junction as a post capillary reactor for peroxyoxalate chemiluminescence detection is presented. Approximate detection limits (e.g. 2.5 x 10<sup>-7</sup>; M for perylene) are …

    utk-theses Repository record for Novel detection alternatives for capillary electrokinetic separations (opens in a new tab)

  7. Integrated micro PEM fuel cell with self-regulated hydrogen generation from ammonia borane

    … hydrogen generator and the micro fuel cell, the dead volume in the gas connection loops can be significantly reduced and the response time of self-regulation is reduced.

    iupui Repository record for Integrated micro PEM fuel cell with self-regulated hydrogen generation from ammonia borane (opens in a new tab)

  8. Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique

    … chamber and a 4-electrode design reduce the dead volume of the micropump and eliminate a need of complicated structure such as valves. The maximum flow rate is about 40 µl/min at 95 V and 14 Hz operation. To improve the performance of the micropump, the chamber design and the electrode …

    uiuc Repository record for Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique (opens in a new tab)

  9. Preliminary Analysis of an Innovative Rotary Displacer Stirling Engine

    … and relatively low power to size and power to volume ratios, limited their widespread applications to date. This study focuses on an innovative Stirling engine configuration that features a rotary displacer (as opposed to common reciprocating displacers), and aims to utilize analytical and …

    unt Repository record for Preliminary Analysis of an Innovative Rotary Displacer Stirling Engine (opens in a new tab)

  10. Concurrent approach for rapid process development and isotherm characterization

    … (i.e., mass transfer) and other (dead volume) system parameters, using only a very small number of runs on an SMB “mini-plant” designed and constructed in-house at Georgia Tech.

    gatech Repository record for Concurrent approach for rapid process development and isotherm characterization (opens in a new tab)

  11. A flow rate measurement system for a mobile emissions measurement system.

    … must be minimized when measuring flow rate. A dead volume of 1.87 in3 was constructed after size experimentation and employed with the Validyne P365 transducer. The complete flow rate measurement system was tested to investigate its integration with the entire MEMS. It was found that the flow …

    wvu Repository record for A flow rate measurement system for a mobile emissions measurement system. (opens in a new tab)

  12. Prediction of time lag in vacuum tubes and its implications for characterization of membranes in constant volume systems: Effect of resistance-free accumulation tank

    … been attributed to an unavoidable presence of a dead volume in the experimental system, i.e. the volume associated with valves, pressure sensors, bypass tubes, etc. A procedure for correcting the experimentally determined transport coefficients of gas in a membrane for the resistance effects has …

    ottawa-retro Repository record for Prediction of time lag in vacuum tubes and its implications for characterization of membranes in constant volume systems: Effect of resistance-free accumulation tank (opens in a new tab)

  13. A Stirling engine for use with lower quality fuels

    … A Stirling engine model based on the finite volume, ideal adiabatic model was developed. Flow dissipation losses are shown to need correcting as they increase significantly at low mean engine pressure and high engine speed. The complete engine including external components was developed. A …

    msu

  14. The effect of wettability, stress, and temperature on the saturation and cementation exponent of the Archie equation

    … brine solution. Porosity was measured from the volume of water injected, after correction for dead volume (non-pore volume), in the equipment. Repeat runs at different wettability and loading conditions were made to measure reproducibility. The confining axial stress and the radial stress were …

    texas Repository record for The effect of wettability, stress, and temperature on the saturation and cementation exponent of the Archie equation (opens in a new tab)

  15. Tuning Plasmid Payload of DNA/polycation Nanoparticles and Validation of a Confined Impinging Jet Mixer for Flash Nanocomplexation Method

    … In an effect to investigate the chamber volume of the confined impinging jet (CIJ) mixer device on nanoparticle production, a scale-down version of the device was designed to allow smaller dead volume. Its performance in nanoparticle production of pDNA/lPEI nanoparticles was validated by …

    jhu Repository record for Tuning Plasmid Payload of DNA/polycation Nanoparticles and Validation of a Confined Impinging Jet Mixer for Flash Nanocomplexation Method (opens in a new tab)

  16. Eliminating scour and excessive volumes in settling tanks using inclined plates.

    … parameters. This tank also proved to have less dead volume than the control tank. Since the reduction in flow through volume proved to be as good and slightly better than the control tank the concept deserves further research. It has the potential to permit considerable tank depth reductions …

    ottawa-retro Repository record for Eliminating scour and excessive volumes in settling tanks using inclined plates. (opens in a new tab)

  17. Silicon-embedded magnetic components for on-chip integrated power applications

    … into the silicon bulk, taking advantage of the 'dead volume' in the substrate and achieving a greater level of miniaturization and integration. As an example, one of the challenges in realizing ultra-compact high-frequency power converters lies in the integration of magnetic components due to …

    gatech Repository record for Silicon-embedded magnetic components for on-chip integrated power applications (opens in a new tab)

  18. Macroscale mixing and dynamic behavior of agitated pulp stock chests

    … flows such as channeling, recirculation and dead zones. Since these non-ideal flows reduce the degree of disturbance attenuation from the chests, they have been considered in the dynamic modeling of the chest. This model allows for two parallel suspension flow paths: a mixing zone consisting …

    ubc Repository record for Macroscale mixing and dynamic behavior of agitated pulp stock chests (opens in a new tab) Download PDF for Macroscale mixing and dynamic behavior of agitated pulp stock chests (opens in a new tab)

  19. PMP-NC² - a normally-closed, backpressure independentperistaltic micropump featuring a modular setup

    … even if the backpressure varies. The stroke volume of one peristaltic movement is 0.64 μL with a maximum deflection of the peristaltic stack actuators of 40 μm. Up to a frequency of 5 Hz the flow rate is linearly dependent (R²=0.99) on the pump frequency and enables precise pumping operations …

    freiburg-diss Repository record for PMP-NC² - a normally-closed, backpressure independentperistaltic micropump featuring a modular setup (opens in a new tab)

  20. Development of MEMS-based chemical pre-concentrators with integrated sensing units for analysis of gas-phase volatile organic compounds

    … The membranes have a large surface area-to-volume ratio but low thermal mass (and therefore, low thermal time constant), with arrays of 3-D high aspect-ratio features formed via DRIE of silicon. Integrated onto the membrane are sets of diffused resistors designed for performing thermal …

    gatech Repository record for Development of MEMS-based chemical pre-concentrators with integrated sensing units for analysis of gas-phase volatile organic compounds (opens in a new tab)

Page 1 of 3